Muonio UV-L 110 Скачать руководство пользователя страница 7

PAGE 7

LOCATING THE UNIT

t

his

 

installation

 

Manual

s

 

guidelines

 

are

 

for

 

inforMa

-

tion

 

only

they

 

do

 

not

 

provide

 

coMplete

 

assurance

 

in

 

individual

 

situations

uv-c 

has

 

significant

 

gerMicidal

 

benefits

depending

 

on

 

exposure

 

dose

 (

based

 

on

 

strength

proxiMity

 

and

 

tiMe

). 

h

owever

there

 

are

 

severe

 

risks

 

to

 uv-c 

exposure

so

 

safety

 

precautions

 

are

 

essential

c

orrectly

 

sized

 

units

 

should

 

be

 

selected

 

for

 

optiMuM

 

disinfectant

 

perforMances

.  t

he

  M

ounio

 

seller

 

or

 

sales

 

agents

 

are

 

available

 

to

 

provide

 

assistance

 

with

 

unit

 

selection

location

 

decisions

 

and

 

other

 

technical

 

suport

 

issues

 

if

 

required

.

t

hese

 

products

 

Must

 

be

 

Mounted

 

and

 

installed

 

correctly

.

t

he

 u

nits

 

May

 

operate

 

as

 

stand

 

alone

 

devices

 

or

 

in

 

coMbi

-

nation

 

with

 

other

 Muonio 

devices

.

uv-c 

radiation

 

has

 

sanitizing

 

properties

 

and

 

has

 

Many

 

uses

 

in

 

coMMercial

healthcare

and

 

consuMer

 

settings

.

t

his

 p

roduct

 

is

 

safe

 

with

 

huMan

/

aniMal

 

presence

 

in

 

the

 

rooM

 

when

 

installed

 

and

 

used

 

correctly

.

t

he

 u

nit

 

Must

 

not

 

be

 

activated

 

when

 

the

 

Metal

 

protective

 

cover

 

is

 

not

 

fastened

 

correctly

 

in

 

place

i

nstall

 

or

 

locate

 

this

 

appliance

 

only

 

in

 

coMpliance

 

with

 

the

 

provided

 

installation

 

instructions

.

p

lease

 

read

 

the

 

warning

 

and

 

Mounting

 

instructions

 

carefully

 

before

 

installing

 

and

 

Mounting

 

the

 u

nit

i

f

 

the

 

Mounting

 

and

 

installation

 

work

 

is

 

incorrect

there

 

is

 

a

 

high

 

risk

 

of

 

injury

 

and

 

daMage

 

to

 

the

 u

nit

 

or

 

other

 

objects

i

f

 

the

 

equipMent

s

 

protection

 

is

 

iMpaired

no

 

rights

 

can

 

derive

 

froM

 

the

 

installation

 

and

 

procedures

 

if

 

the

 

p

roduct

 

is

 

not

 

installed

 

or

 

used

 

in

 

coMpliance

 

with

 

the

 

Manufacturer

s

 

instructions

M

uonio

 

recoMMends

 

that

 

the

 

product

 

installation

 

is

 

by

 

a

 

professional

 

installer

and

 

the

 c

oMpany

 

cannot

 

be

 

held

 

liable

 

for

 

any

 

injury

 

or

 

daMage

 

caused

 

by

 

incorrect

 

installation

 

or

 

asseMbly

d

o

 

not

 

use

 

the

 p

roduct

 

before

 

carefully

 

reading

 

this

 

Manual

a

lways

 

keep

 

this

 

Manual

 

with

 

the

 p

roduct

 

and

 

consult

 

it

 

regularly

MUONIO UV-L 110

 

product

 

contains

 

coMponents

 

that

 

eMit

 uv-c 

light

 

sealed

 

safely

 

inside

 

the

 

Metal

 

enclosure

 

and

 

poses

 

no

 

danger

 

to

 

health

 

in

 

its

 

enclosed

 

state

 

when

 

installed

 

correctly

 

according

 

to

 

these

 

installa

-

tion

 

instructions

f

ailure

 

to

 

follow

 

the

 

warnings

 

in

 

this

 

publication

 

and

 

any

 

other

 

safety

 

guideline

 

regarding

 

the

 

installation

 

or

 

uses

 

of

 uv-c 

products

 

could

 

result

 

in

 

personal

 

injury

t

his

  u

nit

 

contains

 

high

 

energy

 

ultraviolet

  c-

band

 

(uv-c) 

gerMicidal

 

laMps

which

 

can

 

cause

 

teMporary

 

severe

 

eye

 

and

 

skin

 

irritation

. n

ever

 

expose

 

unprotected

 

eyes

 

or

 

skin

 

to

 

the

 uvc 

light

i

MMediate

 

or

 

prolonged

 

exposure

 

to

 uv-c 

light

 

can

 

result

 

in

 

painful

 

injuries

such

 

as

 

eye

 

injury

skin

 

burns

preMature

 

skin

 

ageing

 

or

 

skin

 

cancer

i

t

 

is

 

critical

 

to

 

void

 

exposure

 

to

 

direct

 

or

 

strongly

 

reflected

 uv-c 

light

 

as

 

it

 

can

 

result

 

in

 

harMful

 uv-c 

radiation

 

exposure

d

o

 not 

look

 

directly

 

or

 

indirectly

 

at

 

the

 uv-c 

light

 

when

 

the

 

power

 

is

 

on

for

 

exaMple

during

 

the

 

installa

-

tion

 

or

 

Maintenance

 

activity

.

d

o

 not 

activate

 

the

 u

nit

 

if

 

the

 

Metal

 

cover

 

or

 

any

 

other

 

protective

 

part

 

is

 

daMaged

allowing

 uv-c 

light

 

to

 

be

 

visible

t

he

 u

nit

 

should

 

not

 

be

 

adjusted

 

or

 

repaired

 

by

 

anyone

 

except

 

suitably

 

qualified

 

service

 

personnel

.

i

t

 

is

 

essential

 

not

 

to

 

bypass

 

or

 

taMper

 

with

 

the

 

safety

 

interlocks

.

d

o

 

not

 

operate

 

the

 u

nit

 

if

 

it

 

is

 

daMaged

i

t

 

is

 

crucial

 

that

 

the

 

Maintenance

 

cover

 

is

 

closed

 

correctly

 

and

 

that

 

there

 

is

 

no

 

daMage

 

to

 

the

 

screws

 

or

 

fixings

.

Mounting the Unit on Hollow Walls: 

i

f

 

the

 u

nit

 

is

 

to

 

be

 

installed

 

on

 

a

 

hollow

 

wall

such

 

as

 

hollow

 

bricks

wooden

 

panels

 

or

 

plasterboard

we

 

recoMMend

 

contacting

 

a

 

suitably

 

qualified

 

installer

 

or

 

consult

 

the

 

wall

 

type

 

Manufacturer

 

for

 

a

 

specific

 

recoMMendation

 

for

 

the

 

safest

 

results

.

p

lace

 uv-c 

warning

 

signs

 

near

 

all

 

access

 

panels

 

or

 

doors

 

to

 

a

 

space

 

containing

 

the

 p

roduct

.

Pre- Installation Information

Eye & Skin Burn Hazard

Always isolate the AC mains supply before installing or working 

on any components that require 230 V~, 50 Hz supply. 

Содержание UV-L 110

Страница 1: ...blic places or other spaces at a very eco nomical cost The unit uses well established UV C radiation which was utilised extensively in medical food preparation and other professions for more than 40 years to disinfect the air the cleanliness of the surfaces and to help mitigate the risk of contracting and spreading an infec tion All bacteria and viruses tested to date including various coronavirus...

Страница 2: ...nd Line of Sight 8 Installing the Unit Mounting The Unit on Walls or Ceilings 9 Bracket Dimensions 9 General layout Installation Procedure 10 Terminal Identification Description INSTALLATION WIRING 11 Earth Connection 11 Double Pole Isolation 11 Control Module Connections 11 Power Supply 11 Volt free SWITCHING CONTROL 11 OPTIONAL SWITCH LIVE CONTROL 11 Service Commissioning SERVICE MAINTENANCE 12 ...

Страница 3: ... and microbial compounds including the multi drug resistant strains confirmed a highly effi cient reduction in the number of microorganisms in the testing area The MUONIO UV L 110 UVC radiation unit conformed to the standard showing a significant decrease in the total number of Mesophilic bacteria and the total number of Moulds with a minimum of 2 logarithms to the air s total number of microorgan...

Страница 4: ...ated via app remote control or directly on the device 2 variants Technical Information MUONIO UV L 110 Terminals 0 5 Mm2 To 1 5 Mm2 Dimensions Cca 169 X 171 X 1158Mm Mountable Bracket Horizontal Or Vertical Weight Cca 12 5 Kg Fused Power Supply 230 Vac 50 Hz Single Phase Power Supply 0 41 A Fuse 5 Amp Medium Bur Wireless Frequency 2 4 Ghz With External Antenna only for App controlled device Enclos...

Страница 5: ...ow this symbol to avoid possible injury or death CAUTION indicates a hazardous situation which if not avoided could result in minor or moderate injury DANGER indicates a hazardous situation which if not avoided will result in death or serious injury IMPORTANT Disregard will lead to permanent equipment damage When in operation the product will emit internal UV C radiation UV C radiation is invisibl...

Страница 6: ... the unit periodically check the security of mounting Disconnect the unit from power supply prior to investigating any technical maintenance issue Remove the UV C bulbs if the power supply is required when fault finding the fan or any other component This Manual covers the installation of the UV C fan operated MUONIO UV C Disinfectant Unit Type One UV L 110 MAN The Unit requires a 230 Vac power su...

Страница 7: ... with the Product and consult it regularly MUONIO UV L 110 product contains components that emit UV C light sealed safely inside the metal enclosure and poses no danger to health in its enclosed state when installed correctly according to these installa tion instructions Failure to follow the warnings in this publication and any other safety guideline regarding the installation or uses of UV C pro...

Страница 8: ...s effectiveness depends on the airflow efficiency rate over time This positioning location creates an area that disinfects any air containing droplets or viruses or bacteria passing through the region or deactivates anything circulating into that upper portion of the room with UV C light The Unit protects the occupants by combining upward facing louvres at both ends combined with secondary inward ...

Страница 9: ...safely to solid wall or ceiling surfaces only Warning do not mount the unit vertically Solid brick or concrete block walls must be drilled using a spirit level as a guide to ensure bracket is level and plugs with rawlplugs not supplied The plug and screw fastenings must be located in the solid part of the wall not just in the plaster layer For panelled internal walls or ceilings it is best to loca...

Страница 10: ...illing the wire entry hole 7 Ensure that the unit is secured to the mounting bracket using both locking screws provided on each side to fix it at the final selected angle position 8 Use the mounting bracket to mark the mounting hole centres on the selected wall or ceiling allowing if necessary for the electric cables to pass through the cable entry hole in the centre of the bracket 9 We would reco...

Страница 11: ...cable entry point at the top of the unit The power supply should be connected to N_in Neutral Blue and L_in Live Brown The E Earth Green Yellow must be connected to ground Volt free SWITCHING CONTROL If UV C ventilator is to be operated manually then an external switch must be installed across the Volt Free terminal connections The unit will operate if the volt free terminals make contact through ...

Страница 12: ...actice to replace the lamps once every year In normal circumstances UV C lamp service life is around 9000 hours or running permanently for 1 Year but other factors such as re starts and elements erosion of fillers in the UVC lamp can also affect the quality of output over time Dust can also decrease the lamp s disinfectant efficiency Exercise extreme caution when cleaning the Unit or disposing of ...

Страница 13: ...TINGS BY THE USER OR ANY DAMAGE RESULTED AS FROM SUCH CHANGES THIS WARRANTY SHALL BE VOID IF UV LAMPS FROM MANUFACTURER S OTHER THAN MOUNIO ARE USED WITH THIS EQUIPMENT DAMAGE TO NEW ALL MOUNIO PRODUCTS MUST BE EXAMINED ON RECEIPT PLEASE EXAMINE ALL UNITS AND PACKAGING ANY CLAIMS IN RESPECT TO THE DELIVERED PRODUCTS INCLUDING VISIBLE DEFECTS QUANTITY SHORTAGES OR INCORRECT PRODUCT SHIPMENTS MUST B...

Страница 14: ...centres Avoid hazards to the environ mentanddangerstoyourpersonalhealthbydisposingofthedeviceproperly Forfurtherinformationaboutproper disposal contactyourlocalcouncil wastedisposalofficeortheshopwhereyouboughtthedevice WWW MUONIO ME info nrgawareness com Local Agent AWARENESS CONTACT DETAILS CUSTOMER SIGNATURE_____________________________ DATE________________SERIALNUMBER _________________ WARRANT...

Отзывы: