© Munters Corporation, August 2021
16
QM1231r10
Installation Instructions
Chapter 2
Motor Key
Motor
Motor Sheave
Step 15
Find the Key provided with the Motor and place it in the Keyway on the motor shaft. Place the Motor
Sheave on the Motor shaft with the hub facing towards the motor.
See Figure 15.
ONLY tighten the set
screw enough to hold the Sheave in place at this time.
See Figure 15.
Figure 15
2.4 Motor Mounting
Note:
When wiring motor, check rotation of propeller.
Internal wiring of motor may need to be changed
to assure proper rotation of propeller.
Step 14
If Fans are to be installed 60” O.C., cut the 3 o’clock and 9 o’clock guard wire in the position shown. Push
the side of the cone in as far as possible and fasten the cut guard wire to the attached guard wire using
Clamp [M].
See Figure 14.
Cut Guard Wire Here
Clamp [M]
Figure 14