Solution: Check the USB cable between the touch screen card and the Trio display card.
Problem: There is no 3.3V output for to power the potentiometer(s).
Solution: There is a PPTC fuse F1 on the 3.3V line. Disconnect the potentiometers and using a DVM,
check the resistance on the terminal between the 12V output and common ground (COM). The reading
should indicate an open circuit.
o
If not, the line is damaged.
Problem: The end user doesn’t see changes in the data tables.
Solution:
1. Check the Internet cable, going from RJ-45 connector (marked as Ethernet-2). Verify that the
connector’s LEDs are flashing.
2. Check the Internet cable, going from the power card to the Trio display’s card RJ-45 connector
(marked as Ethernet-1). Verify that the connector’s LEDs are flashing.
23.3
Spare Parts
•
•
•
Trio 20 Door Cards Spare Parts
•
Trio 20 Main Container Spare Parts
•
•
23.3.1
P
RELIMINARY
I
NFORMATION
Trio 20
Container
A
Door Cards
B
Main Container Cards
C
Cables and Harnesses
D
MPN
Munters Part Number
DPN
Dealer Part Number
Содержание Rotem Trio 20
Страница 20: ... Munters AB 2020 20 Figure 6 Relay and port numbering ...
Страница 44: ... Munters AB 2020 44 ...
Страница 99: ... Munters AB 2020 99 Refer to Tunnel Ventilation page 123 for more details ...
Страница 110: ... Munters AB 2020 110 4 Click the fan in the upper right Both fans turn blue 5 Define fans as required ...
Страница 141: ... Munters AB 2020 141 If an outside temperature sensor is enabled map timers to it if required ...
Страница 160: ... Munters AB 2020 160 23 3 2TRIO 20 CONTAINER SPARE PARTS ...
Страница 162: ... Munters AB 2020 162 23 3 3TRIO 20 DOOR CARDS SPARE PARTS ...
Страница 164: ... Munters AB 2020 164 23 3 4TRIO 20 MAIN CONTAINER SPARE PARTS ...
Страница 170: ... Munters AB 2020 170 Card Description Munters Ordering Number TUBES AND FILTERS FOR RPS NO RPS CARD 999 99 00503 ...
Страница 186: ... Munters AB 2020 186 Figure 33 Relay and port numbering 26 2 3POWER Figure 34 Power ports ...
Страница 199: ... Munters AB 2020 199 2 Insert and secure the SMA connector ...
Страница 202: ... Munters AB 2020 202 example only ...