8
Installation
•
•
•
RFS-6 Broiler Container Dimensions
•
RFS-6 Broiler Container Components and Assembly
•
•
8.1
RFS-6 Broiler Installation
The RFS-6 Broiler must be installed by an authorized electrician.
CAUTION
To avoid exposing the RFS-6 Broiler to harmful gases or high humidity, it is recommended to
install the device in the service room.
CAUTION
Installation Category (Overvoltage Category) III.
CAUTION
The power supply to the controller should be protected by a 5 Amps circuit breaker.
WARNING!
Disconnect the power to avoid electrical shock and damage.
To install the RFS-6 Broiler:
1. Open the RFS-6 Broiler controller enclosure lid by unfastening the two screws on the left-hand
side in the front cover. The front cover swings open.
2. Position the required cables through the cable holders at the bottom of the RFS-6 Broiler
controller enclosure. Connect the wires according to the wiring diagrams. Refer to Figure 5.
NOTE:
The
RFS-6 Broiler
must be installed with a
Line Protector (P/N: RPLP-1)
to provide EMI and
lightning protection for the unit’s power input. In limited cases of very noisy power lines an
isolated transformer may also be required.
The
RFS-6 Broiler
controller should be installed a proper distance from high power lines and
other electrical/mechanical equipment (i.e. Augers power, variable speed, dimmers, etc.) or
another noisy units. A distance of at least 0.5 meter distance should be maintained between
the
RFS-6 Broiler
controller and the noise source.
As the load cell cable carries mV it must be a shielded cable grounded on the
RFS-6 Broiler
side. This cable must also not be close to source of noise such as high power cables, and a
distance of at least 0.5 meter distance should be maintained.
The water pulse should also be a shielded cable grounded on one side, and kept a safe
distance from high power cables.