15
Figure 12 and Table 3 detail the FSLC-04 Load Cell dimensions.
Figure 12: FSLC-04 Load Cell Dimensions
Table 3: FSLC-04 Load Cell Dimensions Details
Letter
A
B
C
D
E
ØF
ØG
H
I
X
Y
Dimension (mm)
30.5 130 76.2 25.4
16
Ø13.5 Ø13.5 34.0 30.5
57
4
3.2
FSLC-10 Specifications
Table 4: FSLC-10 Specifications
Parameter
Value
Unit
Rated capacity-R.C. (E
max
)
10,000 /4535
lbs. / Kg.
Rated output-R.O.
3.0 ± 0.10%
mV/V
Zero balance
3.0
±% of rated output
Zero return, 30 min.
0.050
±% of applied load
Total error (per OIML R60)
0.0500
±% of rated output
Temperature effect on zero
0.0070
±% of rated output/°C
Temperature effect on output
0.0040
±% of applied load/°C
Temperature range
–30 to +80
°C
Temperature range, safe
–10 to +40
°C
Maximum safe central
overload
150
% of R.C.
Ultimate central overload
300
% of R.C.
Excitation, recommended
10
VDC or VAC RMS
Excitation, maximum
15
VDC or VAC RMS
Input impedance
380 ± 10
Ω