© Munters AB, 2015
27
3.5
Min/Max Level
IMPORTANT: Before setting Min/Max level, go through and set up the Device Settings,
especially the
Once you have entered the ventilation levels, use the Min/Max to select the range of levels to apply to
your situation. Typically, Farm Premium increases the minimum ventilation level as litter conditions
deteriorate and the birds require greater amounts of fresh air. You can also restrict the maximum level to
prevent excess airflow on young birds.
Go to
Control > Control Mode to select the minimum ventilation method:
o
o
o
o
3.5.1
B
Y
D
AY AND
B
Y
S
OFT
D
AYS
C
URVE
•
Day: Set growth day
•
Min: Set minimum ventilation level for controller
•
Max: Set maximum ventilation level for controller
NOTE:
BY DAYS CURVE generates an incremental increase/decrease between the defined days. BY
DAYS operates according to the min/max values of the day's min/max values until the
following day defined is reached.
3.5.2
B
Y
T
IME
•
From: Set time of day (hh:mm) in 24 hour format
•
Min: Set minimum ventilation level for controller
•
Max: Set maximum ventilation level for controller
MIN/MAX LEVEL
Day
Min
Max
1
3
6
10
14
21
35
0
0
0
1
2
3
4
5
6
7
0
0
0
16
16
16
16
21
21
21
0
0
0
MIN/MAX LEVEL
From
Min
Max
06:00
10:00
13:00
18:00
21:00
00:00
00:00
00:00
00:00
00:00
1
4
6
8
1
0
0
0
0
0
6
8
12
15
3
0
0
0
0
0