![Munster Simms Engineering Ltd. Whale Expanse DW0801U Скачать руководство пользователя страница 19](http://html1.mh-extra.com/html/munster-simms-engineering-ltd/whale-expanse-dw0801u/whale-expanse-dw0801u_installation-and-user-instructions-manual_1856870019.webp)
To the User: Read the following instructions carefully.
Observe All Warnings.
Never operate the Water Heater without water in it. This appliance
must not
be connected directly to the mains
water supply without a pressure regulator fitted, or any water supply greater than 190 kPa (1.9 bar). Ensure that the
caravan water system, including this Water Heater is full of water and that the vehicle is level before operating.
If temperatures are likely to fall below zero degree celsius, you
must ensure
that water is drained from the Water
Heater. (Unless Frost Protection is in operation).
Please note:
The Frost Protection setting is only recommended for a period of 3 days or less. The user
must
ensure
that Frost Protection is turned on, activated and remains in operation for the duration for its period of use.
Frost damage will not be covered by warranty. If the vehicle will not be in use for longer than 3 days, the water
system
must be
fully drained.
The Installer and Vehicle Manufacturer are responsible for providing user instructions and identification of symbols on
the control panel. When using operating switches provided by the Installer or Vehicle Manufacturer, the Installer or
Vehicle Manufacturer are responsible for providing user instructions and identification of symbols on the Control
Panel.
For operation of this Water Heater, a 12V d.c. supply
must be
connected at all times. To operate the Water Heater’s
electric elements, it
must also
be connected to a suitable 230V a.c. supply.
Step One:
Upon initial operation or to refill after the system has been drained, check that the drain valve is
closed, (see Fig. 38A) then fill the system with clean fresh water.
Step Two:
To fill, open one hot tap and switch on the water pump.
Step Three:
Leave the tap open to allow air to escape while the Water Heater is filling. When water flows
smoothly out of the hot tap, the water heater is filled. To allow the remainder of air to escape from the
system, open each hot water tap in turn until water flows smoothly from each tap.
Option 1 Whale® Water Heater Control Panel
Gas Operation.
Operate the left-hand switch to the ‘On’ position. There will be a pre-purge pause of approx. 15
seconds to allow any unburnt gas to leave the flue. A green LED will light upon successful flame ignition. If there is
air in the gas supply line, it may take a few attempts for the gas to ignite. See Section 9 for gas lockout re-setting. If
the ignition is not satisfactory, the red LED will flash - refer to the Trouble Shooting Guide (see section 9).
Electric Operation.
The Water Heater is equipped with twin 750W (230V a.c.) immersion heater elements offering
operation at 750W or 1500W. Operate the right-hand rocker switch to the top position (
~
) to turn on one electric
element. To turn on both electric elements, operate the right-hand rocker switch to the bottom position.
Note:
The electric elements will still operate if the appliance is in gas ignition lock-out.
Gas and Electric Operation.
For faster water heating, the appliance can be operated with both gas and electric
simultaneously. Select ‘Gas On’ (left-hand rocker switch) and one of the electric settings (right-hand rocker switch).
Switching The Appliance Off.
Operate the left-hand gas switch to the centre ‘Off’ position (
O
) and the right-hand
electric rocker switch to the centre ‘Off’ position (
O
).
19
Fig. 35 Whale Water Heater Control Panel
Electric Low Setting
Electric High Setting
Electric Off
Gas Off
Gas On
Gas Lit LED
Diagnostic LED
7. INSTRUCTIONS FOR USE
Frost Protection