Munro Sonic EGG100 Скачать руководство пользователя страница 7

7

EGG100 MONITORING SYSTEM

 

Operation Manual

Equalisation

The EGG100 is naturally neutral in its frequency response. This is mainly a result of the acoustically optimal enclosure 

and the choice of small drivers with almost perfectly controlled directivity. However, not all rooms are neutral and 

also the positioning of the speakers will affect the response. Placing a speaker very near a wall will increase bass and a 

corner will have even more effect. This is because energy is reflected from any surface and that energy will be in phase 

with the direct sound at low frequencies. This might sound like a good thing but without some degree of acoustic 

treatment the results can be unpredictable as at some frequencies the reverse will occur and the reflections will 

tend to cancel the direct energy. The EGG has precision trim potentiometers to equalise the bass and high frequency 

response for a given location. The HF trim can be used to compensate for acoustic imbalances or (more likely) personal 

preference. We all hear high frequencies in slightly different ways and also some allowance may be required for the 

intended reproduction of the recording although almost all media have a ‘flat’ response these days. As a general guide 

a quarter turn (90

o

) will give 2dB of attenuation of the highest octave and that is the preferred setting for most studio 

monitoring applications. 

Control Unit

The EGG is unique in that all the electronics are housed in a separate unit that can be placed within reach of the 

operator and within the listening area. This has several important advantages.

 

All balancing and adjustment can be done without having to move back and forth behind the speakers.

 

The power amplifiers do not compromise the acoustic integrity of the EGG ‘shell’.

 

The unit acts as a volume controller in its own right.

 

The 2m speaker cables allow the unit to be placed in a rack or free standing.

 

Power can be switched without having to clamber behind the speakers.

Protection

The EGG100 is well protected against electronic malfunction. An LED indicates when the system is approaching audio  

clip and this (when illuminated continuously or for more than a few seconds) should be regarded as a warning to 

reduce monitoring level. The high currents used in professional loudspeakers are capable of generating very high 

voice coil temperatures and prolonged loud listening can cause driver failure. Loud transients will pass through the 

system unhindered and the intermittent triggering of the overload LED is quite acceptable. Some manufacturers 

prevent this by limiting and signal processing but this can give a false impression of true dynamic range and can also 

impair sound quality.

The HF driver is fitted with a self resetting thermal fuse, therefore if the HF driver stops working, reduce the level and 

allow a few minutes for the fuse to reset. Then resume working but at a lower level to avoid a repeat.

Setting up your System

Содержание EGG100

Страница 1: ...Operation Manual...

Страница 2: ......

Страница 3: ...ORING SYSTEM Input Amplifier Front Panel Pg 4 Input Amplifier Rear Panel Pg 5 Input Amplifier Side Panel Pg 5 SETTING UP YOUR SYSTEM Setup and Operation Pg 6 Positioning Pg 6 Equalisation Pg 7 Control...

Страница 4: ...lity components and extensively tested to ensure years of trouble free operation If something goes wrong you won t get left without your speaker system If you register your product at www MunroSonic c...

Страница 5: ...one of the correct value 1 2 3 EGG100 Monitoring System INPUT AMPLIFIER SIDE PANEL HF TRIM The HF trim pots are designed to give absolute precision alignment of each channel and adjustment for persona...

Страница 6: ...f a computer monitor or TV screen The EGG100 system includes custom moulded vibration damping nests for the EGGs to sit in These serve several functions and are intended to facilitate the exact alignm...

Страница 7: ...applications Control Unit The EGG is unique in that all the electronics are housed in a separate unit that can be placed within reach of the operator and within the listening area This has several im...

Страница 8: ...s mixing is carried out Frequency Response Reference Data Frequency Response 60Hz to 20KHz 3dB points Low Frequency Room Calibration 0 10dB at 63 Hz continuously variable High Frequency Calibration 1...

Страница 9: ...rnal volume 14 Litres Two way passive crossover 25mm HF unit sensitivity 95dB SPL for 1 W at 1m 100mm LF unit sensitivity 86dB SPL for 1 W at 1m Thermal tweeter protection with automatic cut out and r...

Страница 10: ...iately disconnect the mains plug from the wall and have your system inspected by a qualified technician Only use the voltage as specified as correct for the system supply Always attach the three pin a...

Страница 11: ......

Страница 12: ...3 Hunting Gate Hitchin Hertfordshire SG4 0TJ United Kingdom Tel 44 0 845 500 2 500 www MunroSonic com...

Отзывы: