10.6 Combination button function
With this function, outdoor condenser fan could only work with low speed for noise purpose.
1.
Unit should be with standby condition.
2.
Click “FAN” and “MODE” buttons on the command on board same time, and listen “beep” times from
main PCB
main PCB.
3.
3 times “beep”, means the unit is working with low condenser fan mode all the time, even the indoor
fan is working with high speed.
4.
1 time “beep”, means the unit is working with normal condenser fan mode. When indoor fan is
working with high speed, outdoor condenser fan would work with high speed same time.
10.7 Speed
WZ-32: Cooling: 1250rpm/1000rpm/900rpm Heating:1130rpm/1000rpm/900rpm