6.1 Operation Mode

6.2 Preset Temperature

See  "5.4 OPERARATION MODE" . 

6.2.1 PRESET TEMP. 

PRESET TEMP. function is used to set different temperature on 
different time when the heat mode or cool mode is on. 
 PRESET TEMP.=PRESET TEMPERATURE
  The PRESET TEMP. function will be off in these conditions. 
1

AUTO mode is running. 

2) TIMER or WEEKLY SCHEDULE is running. 
   Go to ''MENU'' > ''PRESET TEMPERATURE'' > 
    ''PRESET TEMP''. Press ''OK''.  
    The following page will appear: 
 

PRESET TEMPERATUER has PRESET TEMP\WEATHER 
TEMP.SET\ECO MODE\COMFORT MODE 4 items. 

use ''''

ǃ

''''

ǃ

''''

ǃ

'''' to scroll and use ''''

ǃ

'''' to adjust the 

time and the temperature. 
When the cursor is on '''', as the following page: 

You press ''OK'', and the '''' becomes ''  ''. The timer 1 is selected.
You press ''OK'' again, and the ''  '' becomes ''''. The timer 1 is 
unselected.

use ''''

ǃ

''''

ǃ

''''

ǃ

'''' to scroll and use ''''

ǃ

'''' to adjust the 

time and the temperature. 
Set six periods and six temperatures can be set. 

 When the space operation mode is changed the PRESET TEMP.  
is off automatically.
 The PRESET TEMP.  function can be used in the heat mode or 
cool mode. But if the operation mode is changed, the PRESET 
TEMP. function need reset again.
 The running preset temperature is invalid when the unit is OFF. It 
will run according to the next preset temperature when the unit turn 
on again.

6.2.2 WEATHER TEMP

SET

 WEATHER TEMP.SET=WEATHER TEMPERATURE SET
 Weather temp.set function is used to preset the desired the water 
flow temperature auto maticly depending on the outside air 
temperature.During the warmer weather the demand for space 
heating is reduced.To prevent the heat pump from producing 
excessing water flow temperature for the  primary circuit, the 
weather temp.set can be used to maximise efficiency and reduce 
running costs.

Go to ''MENU'' > ''PRESET TEMPERATURE''>''WEATHER TEMP. 
SET''. Press''OK''.  
The following page will appear: 

INFORMATION

For example: Now time is 8:00 and temperature is 30

°C. We set the 

PRESET TEMP as follows table.  
The following page will appear: 

TANK 

55 

27 

08:30 

SET 

ON 

ON 

DHW 

MAIN 

8: 00  08 - 08 - 2015 SAT.

NO.   

TIME   

TEMPER   

1   

8:30   

35 

ć

  

2   

9:00   

25 

ć

  

3   

10:00   

35 

ć

  

4   

11:00   

25 

ć

  

5   

12:00   

35 

ć

  

6   

13:00   

25 

ć

  

TEMPER 

35 

ć

  

2 5 

ć

  

8 :30  9 :00   10 :00  11 :00  12 :00  13 :00   

 

 

Controller

9

Owner's & Installation manual

PRESET TEMPERATURE

SCROLL 

1/2 

WEATHER
TEMP.SET

ECO

MODE

PRESET
TEMP.

NO. TIME 

TEMPER 

00:00 25

°

00:00 25

°

00:00 25

°

PRESET TEMPERATURE

SCROLL 

2/2 

WEATHER
TEMP.SET

ECO

MODE

PRESET
TEMP.

NO. TIME 

TEMPER 

00:00 25

°

00:00 25

°

00:00 25

°

PRESET TEMPERATURE

SELECT 

SCROLL 

1/2 

WEATHER
TEMP.SET

ECO

MODE

PRESET
TEMP.

NO. TIME 

TEMPER 

00:00 25

°

00:00 25

°

00:00 25

°

OK 

PRESET TEMPERATURE

SCROLL 

ADJUST 

1/2 

WEATHER
TEMP.SET

ECO

MODE

PRESET
TEMP.

NO. TIME 

TEMPER 

08:30 35

°

00:00 25

°

00:00 25

°

PRESET TEMPERATURE

SCROLL 

ON/OFF 

ECO

MODE

PRESET
TEMP.

COOL  MODE  LOW   TEMP

HEAT  MODE  LOW   TEMP. 

OFF 
OFF 

WEATHER
TEMP.SET

ON/OFF 

PRESET TEMPERATURE

SCROLL 

ON/OFF 

ECO

MODE

PRESET
TEMP.

COOL  MODE  LOW   TEMP

HEAT  MODE  LOW   TEMP. 

ON 

OFF 

WEATHER
TEMP.SET

ON/OFF 

Содержание AEROTHERM V17

Страница 1: ...ima com Thank you very much for purchasing our product Before using your unit please read this manual carefully and keep it for future reference Controller owner s and installation manual SO30170 to S...

Страница 2: ...in electrocution CAUTION Indicates a situation that could result in minor or moderate injury WARNING Indicates a situation that could result in death or serious injury INFORMATION Indicates useful tip...

Страница 3: ...cured Silent mode is activated The disinfect function is activated Holiday away home is activated Backup heater is activated The compressor is activated Desired temp DHW mode the desired temp will not...

Страница 4: ...FHLn SV2 UI SV1 TANK 55 C 27 SET C ON ON DHW ROOM 21 55 08 08 2015 SAT Home page 1 If the WATER FLOW TEMP is set YES and ROOM TEMP is set NON See FOR SERVICEMAN TEMPERATURE TYPE SETTING on installatio...

Страница 5: ...ION PAGE 21 55 08 08 2015 SAT ON ROOM 21 55 08 08 2015 SAT ON MAIN MAIN PAGE ADDITION PAGE TANK C 12 SET C ON ON DHW MAIN 21 55 08 08 2015 SAT 55 SET C 24 21 55 08 08 2015 SAT ON ROOM SV1 FHL1 FHL2 FH...

Страница 6: ...controls The ON OFF of the unit can be controlled by the interface if the ROOM THERMOSTAT is NON see ROOM THERMOSTAT SETTING on INSTALLATION OWNER S MANUAL ON TANK 55 C SET C OFF DHW MAIN 21 55 08 08...

Страница 7: ...tat CONFIRM OK 2 When the cursor is on DHW operation mode Press ON OFF key to turn on off the DHW mode TANK C 12 SET C ON ON DHW MAIN 21 55 08 08 2015 SAT A 55 TANK C 12 SET C OFF ON DHW MAIN 21 55 08...

Страница 8: ...ration mode is Always heat mode heat Always cool mode cool auto A Automatically changed by the software based on the outdoor temperature and depending on installer settings also the indoor temperature...

Страница 9: ...red the water flow temperature auto maticly depending on the outside air temperature During the warmer weather the demand for space heating is reduced To prevent the heat pump from producing excessing...

Страница 10: ...2 3 5 6 7 8 4 6 2 3 ECO MODE Use ECO MODE is used to save energy during the night If ECO mode is activated is displayed on the home page Go to MENU PRESET TEMPERATURE ECO MODE Press OK The following p...

Страница 11: ...ration in DHW mode 6 3 2 Fast DHW 6 3 3 TANK HEATER Go to MENU DOMESTIC HOT WATER TANK HEATER Press OK The tank heater function is used to force the tank heater to heat the water in tank In the same s...

Страница 12: ...STIC HOT WATER DHW SCROLL 1 2 NO START 06 00 00 00 00 00 2 3 00 00 4 1 NO START 00 00 00 00 00 00 6 7 00 00 8 5 DIS INFECT FAST DHW TANK HEATER DHW PUMP DOMESTIC HOT WATER DHW SCROLL 2 2 NO START 06 0...

Страница 13: ...ys at least when we want to enable WEEKLY SCHEDULE function INFORMATION If the weekly schedule function is on the timer is off the later setting is effective If the Timer is activated is displayed on...

Страница 14: ...M page to the MAIN page The TIMER or WEEKLY SCHEDULE is invalid if ROOM THERMOSTAT is effect INFORMATION The ECO or COMFORT MODE has the highest priority the TIMER or WEEKLY SCHEDULE has the second pr...

Страница 15: ...o MENU OPTIONS SILENT MODE Press OK The following page will appear Use ON OFF to select ON or OFF Description If CURRENT STATE is OFF SILENT MODE is invalid When you select SILENT LEVEL and press OK o...

Страница 16: ...15 08 2015 17 08 2015 ENTER SILENT MODE SCROLL ENTER OK CURRENT STATE FROM UNTIL TIMER HOLIDAY AWAY HOLIDAY HOME BACKUP HEATER OPTIONS SILENT MODE SCROLL HOLIDAY AWAY HOLIDAY HOME BACKUP HEATER OPTION...

Страница 17: ...0 ERROR CODE SCROLL PARAMETER SERVICE CALL SERVICE INFORMATION DISPLAY SERVICE CALL E2 E2 E2 E2 14 10 01 08 2015 14 00 01 08 2015 13 50 01 08 2015 13 20 01 08 2015 SCROLL ENTER OK PARAMETER ERROR CODE...

Страница 18: ...will be turned off 6 9 3 How To Exit FOR SERVICEMAN OPERATION PARAMETER P2 COMP PRESSURE2 kPa POWER CONSUMPTION OKWH SCROLL 5 5 OPERATION PARAMETER T1 WATER FLOW TEMP 25 C 30 C T2 PLATE F OUT TEMP 45...

Страница 19: ...TE FROM UNTIL SCHEDULE DISPLAY LANGUAGE BACKLIGHT BUZZER SCREEN LOCK TIME TIME CURRENT TIME CURRENT DAY DOMESTIC HOT WATER DHW DISINFECT FAST DHW TANK HEATER DHW PUMP OPTIONS SILENT MODE HOLIDAY AWAY...

Страница 20: ...1_AHS_OFF t_AHS_DELAY 12 2 PREHEATING FOR FLOOR FLOW SET TEMPERATURE RETURN TEMPERATURE PREHEATING TIME OPERATE PREHEATING FOR FLOOR 12 3 FLOOR DRYING UP DRYING UP TIME HIGE TEMP TIME DRYING DOWN TIME...

Страница 21: ...S 39 38 38 37 37 37 36 36 35 35 34 34 33 33 32 32 31 31 30 30 30 7 T1S 40 40 39 39 38 37 37 36 36 35 35 34 34 33 33 32 32 31 31 30 30 8 T1S 41 41 40 40 39 38 38 37 37 36 35 35 34 34 33 32 32 31 31 30...

Страница 22: ...cooling Table 4 The environment temperature curve of the high temperature setting for cooling 7 7 7 7 7 7 6 7 7 7 7 7 7 6 7 7 7 7 7 7 6 7 7 7 7 7 7 6 7 7 7 7 7 7 6 7 7 7 7 7 7 6 7 7 7 7 7 7 6 7 7 7 7...

Страница 23: ...5 34 34 33 33 32 32 31 31 30 30 30 30 30 30 30 30 30 30 30 8 37 36 35 35 34 34 33 33 32 31 31 31 30 30 30 30 30 30 30 30 Table6 The environment temperature curve of the high temperature setting for EC...

Страница 24: ...he remote signal of the controller to be disturbed refer to the right figure 8 2 1 Installation location 2 2 Preparation before installation 1 2 3 4 5 1 3 2 1 2 GB950 86 M4X20 M4X25 GB823 88 6 3 No Na...

Страница 25: ...el after installation and then install the controller back to the bottom cover 6 Over fasten the lead to deforma tion of back cover outlet P P PP B C Wiring hole x o b n a i c i r t c e l Diameter W P...

Страница 26: ...ASK FOR MORE INFORMATION Phone 34 93 446 27 81 eMail info mundoclima com TECHNICAL ASSISTANCE Phone 34 93 652 53 57 www mundoclima com...