Turn power off and pull out the power plug before cleaning air conditioner.

Don’t sprinkle water on the indoor unit and the outdoor unit for cleaning.

Wipe the units with a dry soft cloth, or a cloth slightly moistened with water or cleanser.

Cleaning the Air Filters (Recommended once every three weeks)

1. Open the surface panel,hold the tab of Air Filter and

raise it slightly, and then take it out.

2. Cleaning

    To clear the dust adhering to the filters, you can either

use a vacuum cleaner, or wash them with water and dry

it in the shade.

NOTE:

 

Never use water above 45

 to wash the filters, or

it could cause deformation or discoloration.

Cleaning surface panel

1. Pull along the direction of arrows to take down surface

panel.

2. Washing

    Wipe with a cloth slightly moistened with water or

cleanser, and then dry it in the shade.

NOTE: Never use water above 45

 to wash the panel,

or it could cause deformation or discoloration.

3. Install surface panel

    Cover the surface panel and clasp it.

CAUTION

Care and Maintenance

Air Filter

Slot

Содержание MUP-062X4C

Страница 1: ...MUND CLIMA Series 2000 Multisplit 4x1 User s manual COOL ONLY MUP 062X4C...

Страница 2: ...ed tightly Otherwise it can cause an electric shock overheating or fire WARNING Don t apply the cold wind to the body for a longtime It cause the physical condition deferioration and health problems W...

Страница 3: ...stop driving and turn off the power suply It occasionally cause the electric shock Don t block the air intake or outlet vents of both the outdoor and indoor units It can decrease the air cond itioning...

Страница 4: ...d function of each part Operation indicator GREEN light up when the unit is on and flashing when the unit is defrosting Air in SET TEMP RUN SIGNAL RECEPTOP Air out Air out STOP 2 3 Air in 1 4 6 7 8 5...

Страница 5: ...omatically and stop when repressed TEMP button SETTEMP increases 1 by pressing button once and decreases 1 by pressing button once At COOL mode operation SET TEMP can be selected from 16 to 30 At DRYm...

Страница 6: ...stopping press TIMER ON button set ON TIME in range of 0 to 24 hour to start the unit automatically SWING FAN SLEEP MODE 1 0 AIR HUMID LIGHT TIMER ON TIMER OFF ANION SAVE SWING HUMID LIGHT SAVE AUTO A...

Страница 7: ...ress SWING button the louvers start to ro tate automatically and stop when repress 1 Plug in press 1 0 button then air conditioner is turned on According to difference between room temp and set temp m...

Страница 8: ...han set temp it s at COOL mode SET TEMP should be in range of 16 to 30 K K K K K 3 Press SWING button the louvers start to ro tate automatically and stop when repress it 4 Press TEMP button set suitab...

Страница 9: ...Remote control operation procedure 11 2 According to room temp micro computer can automatically set operation mode so as for best effect 1 Plug in Press 1 0 button then air conditioner is turned on SW...

Страница 10: ...ON TIME in range of 0 to 24 hour to start the unit automatically At operating press TIMER OFF button set OFF TIME in range of 0 to 24 hour to stop the unit automatically SWING FAN SLEEP MODE 1 0 AIR H...

Страница 11: ...utomatically and stop when repress 6 SLEEP button Press it to set SLEEP operation SWING FAN SLEEP MODE 1 0 AIR HUMID LIGHT TIMER ON TIMER OFF ANION SAVE SWING AUTO FAN OPER When the unit is cooling or...

Страница 12: ...emote control 2 Insert the two batteries Two AAA dry cell batteries and press button ACL 3 Re attach the cover NOTE Don t confuse the new and worn or different batteries Remove batteries when not in u...

Страница 13: ...se compressor would vibrate terribly to damage refrigeration system Don t blow the wind to animals and plants directly It can cause a bad influence to them The ground must be connected Don t connect t...

Страница 14: ...To clear the dust adhering to the filters you can either use a vacuum cleaner or wash them with water and dry it in the shade NOTE Never use water above 45 to wash the filters or it could cause deform...

Страница 15: ...ters and other parts 2 Turn main power off 3 Clean dust from the outdoor unit 4 Repaint the rubiginous place on the outdoor unit to prevent it from spreading Replacement of Air cleaner Recommended onc...

Страница 16: ...n start or stop the unit Air conditioner does not operate at all Cooling Heating effi ciency is not good Once the air conditioner is stopped it will not operate in approximately 3 minutes to protect i...

Страница 17: ...MUNDOCLIMA in following situations Unusual noise can be heard during operation Power fuse or switch often breaks Carelessly splash water or something into air conditioner Electrical lines and power p...

Страница 18: ...17 Circuit Diagram circuit diagram of MUP 062X4C...

Страница 19: ...apping tape Connection piping Thermal insulation hose Air cleaner Plastic square ring Diagram specification 7 1 5V 4G 1 0 ST4 2 25 L 2m 120 65 25 30 10 6 9 5 35 500 Memo Fix the rear panel Qty N N O N...

Страница 20: ...nstallation When picking up and moving the units you must be guided by trained and qualified personnel Installation dimension diagram 3 0 c m o r m o r e Space to the wall Air outlet side 15cm or more...

Страница 21: ...at the distance from the location to the ground is more than 2 3m Outdoor unit 1 Select location from which noise and outflow air emitted by unit will not inconvenience neighbors 2 Select location whe...

Страница 22: ...ing from being damaged when passing through the hole Electrical wiring 1 Open the surface panel 2 Remove the wiring cover 3 Route the power connection cord from the back of the indoor unit and pull it...

Страница 23: ...installed location should be 2 3m or more from the floor NOTE All the electrical work must be done by qualified personnel according to the local rules and this manual The rated voltage and the exclusi...

Страница 24: ...nchor bolts should be within 25mm from each anchor leg CAUTION Be sure to carry out drain piping work following the installation manual If there is some deficiency in draining and pinping work it may...

Страница 25: ...4G1 0 Outdoor unit 220 230V 25A 3 2 5 CAUTION Be careful not to make mis wiring Firmly tighten the terminal screws to prevent them from loosening After tightening pull the wires lightly to confirm th...

Страница 26: ...nit B unit Indoor unit A and B or C and D are in the same refrigerant cycle system so please add enough refrigerant to run both units A and B or C and D Piping preparation Table below shows the specif...

Страница 27: ...Flaring work Perform flaring work using flaring tool as shown in the right Firmly hold copper pipe in a die in the dimension shown in the table above 5 Check Compare the flared work with figure in th...

Страница 28: ...unit For tightening use the same tightening torque applied for indoor unit and tig then the flare nut with torque wrench or spanner Insulation and taping Cover piping joints with pipe cover For outdo...

Страница 29: ...caps for the stop valves 2 way and 3 way valves Leak test Using soapy water perform the leak test for both the indoor and outdoor sides Make sure no bubbles appear on the connections If bubbles appear...

Страница 30: ...stallstion plate When releasing the corner part Release both left and right bottom corner part of indoor unit and pull it downward and forward as shown toto release the hooks If the above method canno...

Страница 31: ...iquid refrigerant such as by inverting the gas cylinder while charging otherwise troubles may be generated To maintain the high pressure of the gas cylinder warm the gas cylinder with warm water under...

Страница 32: ...rocedure AUTO mode operation procedure TIMER mode operation procedure SLEEP mode operation procedure HOW to insert batteries User notices Care and Maintenance Troubleshooting Circuit diagram Accessori...