Munchkin OFB Скачать руководство пользователя страница 3

CONTENTS / USING THIS MANUAL

1

TABLE OF CONTENTS

PART I. COMBUSTION AIR AND VENTILATION

2

A. Fresh Air Intake . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2
B. Air for Combustion  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2
C. Combustion Air Supply with No Barometric Damper  . . . . . . . . . . . . . . . . . . . . . . . . .3

PART II. VENTING REQUIREMENTS

3

A. Neutral Point Pressure Adjuster  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3
B. Roof Clearances  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4
C. Heat Extractors  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4

PART III. NATURAL DRAFT APPLICATIONS

4

PART IV. MECHANICAL DRAFT APPLICATIONS

5

PART V. POWER VENTER APPLICATIONS

6

PART VI. DIRECT VENT APPLICATIONS

7

A. Installing The Joint Assembly . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .7
B. Installing The Outside Terminal . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .8
C. Connections To Outside Terminal  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .9
D. Connections To Appliance  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .9

PART VII. MAINTENANCE

10

PART VIII. CERAFLEX “FLEX L” COMPONENTS LIST

11

DANGER  

Indicates a condition or hazard which
will cause severe personal injury, death
or major property damage.

SPECIAL ATTENTION BOXES  

Throughout this manual you will see these
special attention boxes similar to this one,
which are intended to supplement the
instructions and make special notice of
potential hazards. These categories mean, in
the judgement of Heat Transfer Products, Inc.:

WARNING  

Indicates a condition or hazard which
may cause severe personal injury,
death or major property damage.

CAUTION  

Indicates a condition or hazard which
will or can cause minor personal injury
or property damage.

USING THIS MANUAL

Содержание OFB

Страница 1: ...Venting Manual for Munchkin Oil Fired Boilers Designed and Tested to the A S M E Boiler and Pressure Vessel Code LP 115 REV 6 1 03...

Страница 2: ......

Страница 3: ...ide Terminal 9 D Connections To Appliance 9 PART VII MAINTENANCE 10 PART VIII CERAFLEX FLEX L COMPONENTS LIST 11 DANGER Indicates a condition or hazard which will cause severe personal injury death or...

Страница 4: ...is not operating but the operating automatic damper must fail in the open position The com bustion air duct must have direct access to the outdoors and have a rain hood and insect screen installed at...

Страница 5: ...imneys power venting systems and direct vent systems should also conform to local and State codes and good industry practice In lieu of local codes NFPA 211 should be used as a reference BAROMETRIC DA...

Страница 6: ...nd then slit the stock between the lines ver tically Bend the segments in alternate directions Replace the adjuster start the burner and verify settings taken earlier If unchanged bend tabs against fl...

Страница 7: ...system in use In addition it is strongly recommended that the applicable precautions for Natural Draft Applications be used In addition to all of the pertinent information regarding Natural Draft Appl...

Страница 8: ...sagging Follow the national codes for the installation of oil burning equipment in USA NFPA 31 in Canada CAN CSA B139 and local regulations Figure 2 PART V POWER VENTER APPLICATIONS When using a power...

Страница 9: ...a thicker wall That the Heat Transfer Products Inc Flex L System is not designed for common venting Use this for a single appliance only unless otherwise approved Utilize an appliance adapter test po...

Страница 10: ...UTSIDE TERMINAL Using Figure 6 and Figure 7 page 9 com plete the following steps 1 Determine the terminal location 2 Cut 8 1 4 diameter hole through the wall slightly larger than the O D of the termin...

Страница 11: ...luminum tape and secure using air intake clamp Beaded end of the air intake clamp should go first over the air intake collar 9 Seal the gap between the vent pipe and the inner section with silicone se...

Страница 12: ...PRODUCTS INC and Flex L International Inc recommends the entire heat ing system including the appliance and vent to be checked annually by a qualified heating professional THE CERAFLEX VENT TERMINAL...

Страница 13: ...MAINTENANCE 11 THE CERAFLEX INSULATED VENT PIPE IS 1 CLEARANCE TO COMBUSTIBLES Figure 10 Figure 11 Figure 12 Figure 13...

Страница 14: ...Pipe 20 Length CFV204 CeraFlex Appliance Adapter w Pt 6 4 CFAA64P CeraFlex Terminal Adapter 4 4 CFAT44 CeraFlex Vent Terminal 4 CFT4 CeraFlex Air Intake Flex 10 x4 L10 04 CeraFlex Air Intake Flex 15 x...

Страница 15: ...FOR FURTHER TECHNICAL INFORMATION CONTACT HEAT TRANSFER PRODUCTS Inc 120 Braley Road PO Box 429 East Freetown MA 02717 0429 508 763 8071...

Страница 16: ......

Отзывы: