Chapter 1 – AT Commands, S-Registers and Result Codes
Multi-Tech Systems, Inc. SocketModem MT5600SMI/MT5656SMI Reference Guide (S000306C)
58
Register Unit Range Default Description
S210
0–255 13
(0Dh)
V.34 Symbol Rate.
The bits in this parameter control V.34 symbols rates
and enable/disable V.34 asymmetric rates. This parameter is used for
diagnostic purposes only.
Default: 13 (0Dh) (00001101b)
Bits 0 -2 Selects the range of allowed V.34 symbol rates.
2
1
0
Symbol Rates (baud)
0 0 0 2400
only
0 0 1 2400
only
(no
2734)
0 1 0 2400,
2800
0 1 1 2400,
2800,
3000
1 0 0 2400,
2800,
3000,
3200
1
0
1
2400, 2800, 3000, 3200, 3429 (Default.)
Bit 3 Enable/disable V.34 asymmetric rates.
0 =
Disable asymmetric rates
1 =
Enable asymmetric rates (Default.)
Bits
4-7
Reserved.
Examples
S210=13
Enable asymmetric rates with all symbol rates available
(Default.).
S210=5
Disable asymmetric rates with all symbol rates
available.
S210=8
Enable asymmetric rates with only 2400 baud available.
S210=11
Enable asymmetric rates with 2400 to 3000 baud
available.
*
Register value may be stored on one of two user profiles with the
&W
command.