When I try to make a data call using ‘ATD<number>’, I get a NO CARRIER response.
•
Check ‘AT+CEER’ for NO CARRIER reason and look it up in Reference Guide.
•
Check the number that you are dialing.
•
Make sure you have CSD service.
•
Check registration and signal to make sure modem is registered and getting good signal: +CREG, +CSQ.
•
Make sure you went through the activation procedures correctly.
How do I make a CSD dial-up connection in Windows to my ISP?
•
Create a dial-up connection to the ISP’s access # and use the correct password and username.
•
You must have CSD service.
Does this modem support High-Speed Circuit-Switched Data (HSCSD)?
•
No, our CDMA modems do not support HSCSD.
The modem will not answer.
•
Set the modem to autoanswer with ‘ATS0=1’ and ‘AT&W’ to store the setting.
•
Send ‘ATA’ to the modem once the RING is indicated on the terminal screen.
•
You may need to set the modem to ignore DTR, ‘AT&D0’, if your system doesn’t provide DTR.
The modem answers, but does nothing.
•
Modem is answering in voice mode.
•
Voice: Need a voice cable; such as our “Y” cable.
•
Data: Make sure you set ‘AT+CICB=0’ to make the modem answer in data mode.
How does faxing work?
•
The CDMA modems only support Class 2.0 Group 3 faxing.
•
Need fax services setup on the account.
•
Need fax software that supports the modem; e.g., WinFax Pro v10.0.
•
Need to set ‘AT+CICB=1’ for modem to answer in fax mode.
When I set the S0 command, store it with &W; then send “ATZ” to the modem, the command goes back to
the default of 0?
•
This is a bug in the modem. S0 will store just fine, as long as “ATZ” doesn’t get sent to the modem.
After I set the E and &D commands followed by &W, it looks to be stored okay, but as soon as I recycle
power on the unit the E and &D commands get set back to default of E1 and &D2.
•
This is a bug in the modem. These commands will not store correctly. If modems are powered back up and
an “ATZ” is sent to the modem, then &D and E will load to your stored settings correctly.
•
Firmware versions 210 and above fixes the storage or the E command.
After I set the Q, V, and &S commands followed by &W, if I recycle power or send ATZ to the modem the
settings will get set back to default.
•
Bug in the modem. These commands will not store.
What is the max supported serial baud rate?
•
230,400 bps is the max.