Chapter 4 - AT Commands, S-Registers, Result Codes
27
MultiModemDID User Guide
automode An optional numeric value that enables or disables automatic
modulation negotiation using V.8 bis/V.8 or V.32 bis Annex A.
Automode is disabled if values are specified for the
max_rate
and
max_rx_rate parameters. The options are:
0 Disable automode
1 Enable automode (default)
max_rate An optional number that specifies the highest rate at which the
modem may establish an upstream (transmit) connection. The
value is decimal coded in units of bps, for example, 33600
specifies the highest rate to be 33600 bps.
0 Maximum rate determined by the modulation selected in
mod
(default).
300–33600 Maximum rate value limited by the modulation selected in
mod.
For valid
max_rate values for each mod value, see the
following table.
mod
value
Valid max-rate values (bps)
V92, V90, V34
31200, 28800, 26400, 24000, 21600,19200,
16800, 14400, 12000, 9600, 7200, 4800, 2400
V32B
19200, 16800, 14400, 12000, 9600, 7200, 4800
V32
14400, 12000, 9600, 7200, 4800
V22B
2400
V22, V23C, Bell212A
1200
V21, Bell103
300
max_rx_rate An optional number that specifies the highest rate at which the
modem may establish a downstream (receive) connection. The
value is decimal coded in units of bps, e.g., 28800 specifies the
highest rate to be 28800 bps.
0 Maximum rate determined by the modulation selected in
mod
(default).
300–56000 Maximum rate value limited by the modulation selected in
mod.
See “Possible rates” in the
mod table.