98
MultiFRAD User Guide
Appendix D - Disabling the Internal DSU
Perform the following procedure if your WAN network has been upgraded to T1/E1 and you now want
to
disable the MultiFRAD’s internal DSU and use the back panel Trunk connection to obtain data
rates of up to 2.048 Mbps.
1
Turn off the MultiFRAD using the back panel Power switch.
2
Locate the access window (side slot opening) near the left front corner of the MultiFRAD.
3
Using a small flat blade screwdriver or similar tool, press
down on DIP Switch 2
(Figure D-1) until it is even with all the other DIP switches; the internal DSU is now disabled.
OPEN
1 2 3 4 5 6 7 8
DIP switch 2 UP; internal DSU is enabled.
DIP switch 2 DOWN; internal DSU is disabled.
OPEN
1 2 3 4 5 6 7 8
Figure D-1. DIP Switch 2 Location and Functions
4
If your trunk connection is V.35 rather than the default RS232C, refer to V.35 Shunt
Procedure in Chapter 2 - Installation and move the Trunk shunt to the V.35 socket.
5
Disconnect the RJ-45 cable from the DSU jack and connect a trunk cable (Appendix A) to the
DB25 female TRUNK connector on the back panel of the MultiFRAD.
6
Reapply power to the MultiFRAD, then configure the Trunk port as the WAN connection.
Содержание MultiFRAD FR221
Страница 1: ...MultiFRAD 200 Series Models FR221 FR221 V2 User Guide...
Страница 5: ...Chapter 1 Introduction and Description...
Страница 13: ...Chapter 2 Installation...
Страница 21: ...Chapter 3 Software Loading and Configuration...
Страница 38: ...38 MultiFRAD User Guide...
Страница 39: ...Chapter 4 MultiFRAD Software...
Страница 73: ...Chapter 5 Remote Configuration and Management...
Страница 80: ...80 MultiFRAD User Guide...
Страница 81: ...Chapter 6 Warranty Service and Tech Support...
Страница 87: ...Appendixes...
Страница 99: ...Glossary...