PRODUCT OVERVIEW
MultiConnect
®
rCell 100 Cat M1/NB-IoT MTR-MNG2 Hardware Guide
13
Power Draw
MTR-MNG2-B10 Power Draw
Radio Protocol
Cellular Call Box
Connection No
Data (mA)
Average Measured
Current (mA) at
Maximum Power
1
TX Pulse (Avg)
Amplitude Current
(mA) for GSM850 or
Peak Current for
HSDPA/LTE
2
Total Inrush Charge
Measured in
Millicoulombs (mC)
3
9.0 Volts
GSM 850 Mhz
282
415
1030
.832
LTE
305
370
432
.832
12.0 Volts
GSM 850 Mhz
211
300
725
.737
LTE
227
272
352
.737
24.0 Volts
GSM 850Mhz
115
158
355
.812
LTE
123
145
220
.812
1
Max Power:
The continuous current during maximum data rate with the radio transmitter at maximum power.
2
Tx Pulse
: The average peak current during a GSM850 or LTE transmission burst period. The transmission burst
duration for GSM850 can vary, depending on what transmission scheme is being deployed (GPRS Class 8, Class 10,
GSM, etc.).
3
Total Inrush Charge
: The total inrush charge at power on expressed in Millicoulombs (mC).
Note:
Multi-Tech Systems, Inc. recommends that you incorporate a 10% buffer into the power source when
determining product load.