INSTALLING AND USING THE DEVICE

Installing and Using the Device

Installing the Device

1.

Connect a suitable antenna to the antenna connector.

2.

If you are using the serial version of this device:
Connect the DB9 male connector (9-pin) of the RS-232 cable to the RS-232 connector on the device, then
connect the other end to the serial port on the other desired device.
Screw-on the power lead from the power supply module into the power connection on the device.
Plug the power supply into your power source.

3.

If you are using the USB version of this device:
For information about the USB cable that helps power your device, see the section "USB Cable
Recommendations."
The USB cable uses power from the USB power line. Connect one end of the USB cable to your computer
or other USB high power device, such as a hub.
Connect the other end to the device's USB connector.

4.

The POWER LED lights after the device powers up.

Placing Serial Devices in Power Save Mode

You can place devices that have a serial connector in low power mode. When the device is in low power
mode—which is also sometimes called sleep mode or power save mode—the device's radio is operating with little
power. A power save switch on the device determines if the device's radio can operate in normal or low power
mode.

You might want your device to go into low power mode if batteries are used to power the device. For example,
you might want to use your device outdoors, and have it powered by a solar charged battery. By using low power,
you can save time and money by not having to replace batteries on devices operating in the field.

You can use many techniques to place the device into low power (sleep) mode. This example uses data terminal
ready (DTR) and the AT cCFUN=5. For other techniques, review the AT command guide for your device,
as described in the Documentation topic in this guide.

You can make the device "wake up" from sleep mode by using the wake-on-ring feature: In the example that
follows, the ring indicator line wakes the host processor when the radio receives an incoming call or SMS message.
Your application then needs to act on the ring indication and wake up the device by asserting DTR.

Using Low Power Mode

To set up the device so it can be placed into low power mode:

1.

Set the power-save switch to LOW.

2.

On the RS-232 interface, ensure your application controls DTR and makes it active (on). To configure the
device for DTR control, issue either AT&D1 or AT&D2 for DTR control. The &D0 command does not allow
low power to operate.

3.

To configure the device to enter low power (sleep) mode, issue AT+CFUN=5 to the radio.

4.

To configure the device to wake from low power mode by using the wake-on-ring feature, issue
AT#E2SMSRI=1000. This configures the ring indicator to go active for 1000 ms when an SMS message is
received.

16

MultiConnect

®

Cell MTC-H5 User Guide

Содержание MultiConnect Cell MTC-H5

Страница 1: ...MultiConnect Cell MTC H5 User Guide...

Страница 2: ...on or communications systems control equipment for nuclear facilities or missile nuclear biological or chemical weapons or other military applications Restricted Applications Use of the products in su...

Страница 3: ...nada 14 Avertissements relatifs l installation et aux emplacements dangereux 14 ATEX Europe only 14 Hazardous Location Special Considerations 14 Antenna 15 Installing and Using the Device 16 Installin...

Страница 4: ...ver 28 Downloading File from FTP Server 29 Reading Writing and Deleting Messages 30 Reading Text Messages 30 Sending Text Messages 30 Deleting Messages 31 Regulatory Information 32 Industry Canada Cla...

Страница 5: ...open interfaces Documentation The following documentation is available on the Multi Tech Installation Resources website at www multitech com setup product go Document Description MultiConnect Cell Us...

Страница 6: ...lished LS Link Status Not lit There is no power to the cellular radio Continuously Powered and connected but not transmitting or receiving lit Slow blink Powered and searching for a connection Fast bl...

Страница 7: ...formance HSPA GPRS EDGE Cell 850 824 894 MHz Frequency Bands Cell 900 880 960 MHz Cell 1800 1710 1880 MHz Cell 1900 1850 1990 MHz Radio Cellular Telit HE910 D Speed Packet Data Up to 7 2 Mbps downlink...

Страница 8: ...A C22 2 No 213 EN 60079 0 2012 A11 2013 EN 60079 15 2010 Network Compliance GCF PTCRB Warranty Two years 1 Device has been tested up to 85 C UL Recognized 40 C limited by AC power supply UL Recognized...

Страница 9: ...n Abbreviation Description In Out 3 TX Transmit I 4 DTR Data Terminal Ready I 5 GND Ground 6 DSR Data Set Ready O 7 RTS Request to Send I 8 CTS Clear to Send O 9 RI Ring Indicator O MultiConnect Cell...

Страница 10: ...p Mode Cellular call box Average TX Pulse AVG Total inrush Current amps connection no measured current Amplitude charge measured data amps amps at Current amps in MilliCoulombs maximum power mC 7 volt...

Страница 11: ...PRODUCT OVERVIEW Dimensions Serial MultiConnect Cell MTC H5 User Guide 11...

Страница 12: ...PRODUCT OVERVIEW USB 12 MultiConnect Cell MTC H5 User Guide...

Страница 13: ...cy energy RF from cellular devices can interact with some electronic devices This is electromagnetic interference EMI The FDA helped develop a detailed test method to measure EMI of implanted cardiac...

Страница 14: ...fournira uniquement un acc s au modem gr ce une cl ou un outils sp cifique 2 CET QUIPEMENT EST ADAPT EXCLUSIVEMENT POUR UNE UTILISATION EN ZONE DE CLASSE I DIVISION 2 GROUPES A B C ET D OU EN ZONE NON...

Страница 15: ...for use with this unit meets the requirements for mobile operating configurations and for fixed mounted operations as defined in 2 1091 and 1 1307 of the FCC rules for satisfying RF exposure complianc...

Страница 16: ...power mode if batteries are used to power the device For example you might want to use your device outdoors and have it powered by a solar charged battery By using low power you can save time and mon...

Страница 17: ...mputer chassis Use USB 3 0 ports if available These ports are typically rated for more current You can re order the USB cable through Multi Tech The part number is CA USB A MINI B 3 Installing a SIM C...

Страница 18: ...he downlink connection cell tower to mobile It has no effect on the uplink mobile to cell tower Antenna diversity is useful in environments where the signal arrives at the device after bouncing off or...

Страница 19: ...ds of operation Maximum Radiated Gain 3 dBi Radiation Omni directional Polarization Linear Vertical Antenna The antenna intended for use with this unit meets the requirements for mobile operating conf...

Страница 20: ...network To find activation steps for your device 1 Go to http www multitech com support 2 Select your device 3 Scroll to Activation and click Download Device Phone Number Every device has a unique ph...

Страница 21: ...pppd and chat programs are also required pppd needs two scripts the first script performs the environment setting and calls the second script which is used by the chat program For creating a PPP conne...

Страница 22: ...omp nopcomp noaccomp For sanity keep a lock on the serial line lock Show password in debug messages show password This script calls the option connect using the script hsdpa_connect for example bin sh...

Страница 23: ...ate the connection to the cellular TCP IP network This provides Internet access for sending and receiving email creating TCP UDP Sockets or putting and getting files from an FTP server Before You Begi...

Страница 24: ...eceived signal strength indication 0 113 dBm or less 1 111 dBm 2 30 109 dBm 53 dBm 2 dBm per step 31 51 dBm or greater 99 Not known or not detectable ber Bit error rate in percent 0 Less than 0 2 1 0...

Страница 25: ...evice responds with the IP Address the cellular provider assigned to the device on connection followed by OK For example SGACT 25 194 185 116 OK 2 Create Client Connection to TCP Server on Port 500 En...

Страница 26: ...h and unsolicited indication that a host is trying to connect to connection ID 1 on port 7000 SRING 1 7 Accept incoming connection ID 1 Enter AT SA 1 The device indicates a client successfully establi...

Страница 27: ...t connection Exit Data Mode and Close Connection To exit data mode and close the socket Enter the escape sequence To close Socket 1 enter AT SH 1 The device responds with OK To close the data connecti...

Страница 28: ...a Exit Data Mode and Close Connection To exit data mode and close the socket Enter the escape sequence To close Socket 1 enter AT SH 1 The device responds with OK To close the data connection enter AT...

Страница 29: ...ction Enter AT FTPCLOSE 3 Close the PPP data connection Enter AT SGACT 1 0 The device responds with OK Downloading File from FTP Server To connect to an FTP server and download files 1 Check signal st...

Страница 30: ...osing the FTP Data Connection When you finish sending the file 1 Close the FTP connection Enter AT FTPCLOSE 2 Close the PPP data connection Enter AT SGACT 1 0 The device responds with OK Reading Writi...

Страница 31: ...select storage and is the delflag option Enter 0 Deletes message in the specified index 1 Deletes all read messages Leaves unread messages and stored device originated messages 2 Deletes all read and...

Страница 32: ...ust accept any interference including interference that may cause undesired operation of the device Cet appareil est conforme avec Industrie Canada RSS exemptes de licence standard s et la partie 15 d...

Страница 33: ...ction retry algorithm If you fail to do so Aeris might block network access for your devices After your devices reach the end of their commercial lifespan you must remove them from the Aeris network T...

Страница 34: ...These MultiTech products do not contain the following banned chemicals1 Lead Pb 1000 PPM Mercury Hg 1000 PPM Hexavalent Chromium Cr 6 1000 PPM Cadmium Cd 100 PPM Polybrominated Biphenyl PBB 1000 PPM P...

Страница 35: ...rt of a formal quality system and will be made available upon request Waste Electrical and Electronic Equipment Statement WEEE Directive The WEEE Directive places an obligation on EU based manufacture...

Страница 36: ...r PBDE PBB Printed Circuit Boards O O O O O O Resistors X O O O O O Capacitors X O O O O O Ferrite Beads O O O O O O Relays Opticals O O O O O O ICs O O O O O O Diodes Transistors O O O O O O Oscillat...

Страница 37: ...s Inc TS HS PB Hg CD CR6 PBB PBDE O O O O O O X O O O O O X O O O O O O O O O O O O O O O O O ICs O O O O O O O O O O O O X O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O LEDs O...

Отзывы: