Multitech MTD-EV3 Скачать руководство пользователя страница 20

BASIC OPERATIONS

Basic Operations

Interacting with Your Device Overview

This section describes how to use AT commands to interact with your device. Using terminal software such as
Kermit, you can issue AT commands to communicate with and configure your modem. The AT commands let you
establish, read and modify device parameters and help you control how the device operates. This section
documents basic interactions with your device, such as verifying signal strength and network registrations, sending
and reading SMS text messages, and sending and receiving data.

Generally, USB modems are used as unintelligent bit pipes. In Windows, this means you create a dial-up network
connection that uses the Windows IP stack to use the modem to create a PPP connection to the cellular network.
The modem is assigned an IP address from the cellular carrier. This connection provides Internet access and is the
basis for TCP/IP communication for sending and receiving email, creating TCP/UDP Sockets, or putting and getting
files from an FTP server.

In Linux, PPPD is used to dial the modem and create the connection to the cellular TCP/IP network. This provides
Internet access for sending and receiving email, creating TCP/UDP Sockets, or putting and getting files from an FTP
server.

Related Documentation

Related documentation for using EV-DO EV3 devices:

EV-DO EV3 AT Commands Reference Guide (S000546) provides for additional information on AT commands
available for your device. The Introduction chapter describes command formatting, syntax, and other basic
information.

Before You Begin

Before you begin:

If you have not done so, install any drivers. Refer to the separate driver installation guide for your device.

Power up your device and ensure it is connected to the computer that you use to issue AT commands.

Install terminal software that can communicate with the device, such as HyperTerminal, TerraTerm, Kermit,
or Putty.

Preparing the Modem for a Data Connection

Set the APN by issuing the following command where <APN Name> is the APN assigned by the carrier.

AT+CGDCONT=1,"IP","<APN Name>

Check for registration by issuing

AT+CREG?<cr>

and wait for the response. If the second value of the response (for

example, +CREG:x,y) is 1, then the modem is registered on the home network. If y=5, then the modem is registered
but roaming. See the AT Command reference guide for other possible responses. If the second value is not 1 or 5,
then do not attempt to dial. Wait ~5 seconds for the modem to finish registration and check +CREG again.

Using the Radio IP Stack to Make a Data Connection

Connect by issuing the command:

AT#SGACT=1,1

(using PDP context #1).

20

QuickCarrier

TM

USB-D EV-DO MTD-EV3 User Guide

Содержание MTD-EV3

Страница 1: ...QuickCarrierTM USB D EV DO MTD EV3 User Guide...

Страница 2: ...port machines or other life preserving medical devices or systems air traffic control or aircraft navigation or communications systems control equipment for nuclear facilities or missile nuclear biolo...

Страница 3: ...1 Powering Off or Rebooting a Device 11 Device Phone Number 11 Using Connection Manager to Install Drivers Activate a Device and Connect to the Carrier Network 11 Troubleshooting 12 Account Activation...

Страница 4: ...g Text Messages 23 Deleting Messages 24 Carrier Information 24 Regulatory Statements 26 47 CFR Part 15 Regulation Class B Devices 26 Industry Canada Class B Notice 26 EMC Safety and R TTE Directive Co...

Страница 5: ...g USB drivers on Linux and Windows Devices Systems Part number S000569 EV DO and CDMA AT Commands Reference Configure your device with the EV DO and CDMA AT Commands Guide Reference Guide Part number...

Страница 6: ...005 set for SMS Mobile Terminated SMS Mobile Originated SMS Certifications and Compliance EMC Compliance FCC Part 15 Class B Radio Compliance FCC Part 22 FCC Part 24 RSS 132 RSS 133 Safety Compliance...

Страница 7: ...ulombs cha without Data with Data rge time max max CDMA 800 5 45ma 576ma 1160mC 19use c CDMA 1900 5 133ma 592ma 1160mC 19use c Note Steady State Maximums Radio is registered and is transmitting at the...

Страница 8: ...te the device Do not place the antenna outdoors Switch OFF your wireless device when in an aircraft Using portable electronic devices in an aircraft may endanger aircraft operation disrupt the cellula...

Страница 9: ...Stop the pacemaker from delivering the stimulating pulses that regulate the heart s rhythm Cause the pacemaker to deliver the pulses irregularly Cause the pacemaker to ignore the heart s own rhythm an...

Страница 10: ...ES AND WARNINGS User Responsibility Respect all local regulations for operating your wireless device Use the security features to block unauthorized use and theft 10 QuickCarrierTM USB D EV DO MTD EV3...

Страница 11: ...ering Off or Rebooting a Device Note When reconnecting the device use the same USB port that you used when installing drivers Otherwise you may need to re install the driver Powering Off or Rebooting...

Страница 12: ...rtup and automatically connect to the internet a Click Settings and check the boxes for Run application at Windows startup and Connect to the Internet Automatically b Click Apply 8 To allow Connection...

Страница 13: ...vices to their network To find activation steps for your device 1 Go to http www multitech com support 2 Select your device 3 Scroll to Activation and click Download Creating a Windows Dial Up Connect...

Страница 14: ...pplications interacting with Sprint approved Multi Tech devices must be written in a manner where they do not interfere interrupt the Sprint HFA process or OMA DM processes outlined in section labeled...

Страница 15: ...nreachable server 913 HFA Error network error 914 HFA Done HFA success 922 HFA Done No profile received 923 HFA Error ETC 924 HFA Cancelled DREL Data session release Network Initiated Device Configura...

Страница 16: ...ware Update Success 929 402 FUMO Firmware corrupted CRC error 929 403 FUMO Firmware package mismatch 929 404 FUMO Firmware signature failed 929 406 FUMO Firmware update authentication failed 929 410 F...

Страница 17: ...OMA DM Client Initiated Device setting AT PRL onoff Set OMA DM CIPRL Session Disable 0 Enable 1 Initiate 2 AT PRL Query OMA DM CIPRL Session setting AT FUMO Set OMA DM FUMO enable parameter Disable 0...

Страница 18: ...s the environment setting and calls the second script which is used by the chat program For creating a PPP connection type pppd file etc pppd_script Example Debug info from pppd debug kdebug 4 Most ph...

Страница 19: ...es usepeerdns No ppp compression novj nobsdcomp novjccomp nopcomp noaccomp For sanity keep a lock on the serial line lock Show password in debug messages show password This script calls the option con...

Страница 20: ...getting files from an FTP server Related Documentation Related documentation for using EV DO EV3 devices EV DO EV3 AT Commands Reference Guide S000546 provides for additional information on AT comman...

Страница 21: ...de and ready to accept AT commands Use AT commands to communicate with and configure your modem They allow you to establish read and modify device parameters and control how the modem works The device...

Страница 22: ...known or not detectable Note Signal strength of 10 or higher is needed for successful packet data sessions Example A example response to AT CSQ CSQ 15 1 Checking Network Registration Before establishi...

Страница 23: ...ed call drops for any reason Wait 30 seconds and restart the sequence again Reading Writing and Deleting Messages Reading Text Messages To read a text message in text mode 1 Put the device in text mod...

Страница 24: ...read messages Leaves unread messages and stored device originated messages 2 Deletes all read and sent device originated messages Leaves unread messages and unsent device originated messages 3 Deletes...

Страница 25: ...it for response OTASP 2 6 Modem will reset when done with the activation 7 Close terminal program 8 Unplug and replug the USB cable 9 Check registry with AT_REG Check the Multi Tech website for the la...

Страница 26: ...elp Warning Changes or modifications to this unit not expressly approved by the party responsible for compliance could void the user s authority to operate the equipment Industry Canada Class B Notice...

Страница 27: ...terminal equipment and the mutual recognition of their conformity International Modem Restrictions Some dialing and answering defaults and restrictions may vary for international modems Changing sett...

Страница 28: ...of specified percentages per the WEEE requirements Instructions for Disposal of WEEE by Users in the European Union The symbol shown below is on the product or on its packaging which indicates that th...

Страница 29: ...MultiTech products do not contain the following banned chemicals1 Lead Pb 1000 PPM Mercury Hg 1000 PPM Hexavalent Chromium Cr 6 1000 PPM Cadmium Cd 100 PPM Polybrominated Biphenyl PBB 1000 PPM Polybro...

Страница 30: ...SVHC Per the candidate list of Substances of Very High Concern SVHC published October 28 2008 we have reviewed these substances and certify the Multi Tech Systems Inc products are compliant per the EU...

Страница 31: ...PBB Printed Circuit Boards O O O O O O Resistors X O O O O O Capacitors X O O O O O Ferrite Beads O O O O O O Relays Opticals O O O O O O ICs O O O O O O Diodes Transistors O O O O O O Oscillators an...

Страница 32: ...TS HS PB Hg CD CR6 PBB PBDE O O O O O O X O O O O O X O O O O O O O O O O O O O O O O O ICs O O O O O O O O O O O O X O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O LEDs O O O...

Страница 33: ...ager 11 12 shell commands 18 D M data bits 21 maintenance 9 data connection 20 modem delete text messages 24 safety 8 device maintenance 9 N dialing restrictions 27 dial up connection 13 network regis...

Страница 34: ...interference 8 signal strength verify 21 U specifications 5 user responsibility 10 speed 21 Sprint 14 15 16 stop bits 21 V s curit verify communication 21 interf rences RF 8 W T Windows temperatures...

Отзывы: