Chapter 2 - Front & Back Panel Descriptions

2.3

Back Panel

All the cable connections, including one power connection and two signal connections,  are made at the back
panel of the DSU.  The RS232 connector is used to connect the DSU to an RS232 or V.35 device, and the
LINE connector connects to a DDS or LADS (Local Area Data Set) circuit.  The cable connections are shown
in Figure 2-2 and defined in the following sections.

POWER

LINE

RS232

Figure 2-2.  Back Panel

2.3.1 POWER Connector

The POWER connector is used to connect the external wall type transformer power supply to the DSU.  The
wall transformer plugs directly into an AC outlet.

2.3.2 RS232 Connector

The RS232 (Data) connector is used to connect the DSU to a sync device, such as, multiplexers, routers, or
legacy equipment such as cluster controllers.  The RS232 connector is a DB-25 female connector located on
the back panel of the DSU.

The RS232 data connector interface can be switched to a V.35 interface.  For the V.35 interface, an internal
data shunt has to be moved from the default RS232 position to the V.35 position.  To change the shunt, refer
to the "Shunt" paragraph in this chapter.  Also refer to Appendix A for special cabling requirements for the
V.35 mode.

2.3.3 LINE Connector

The LINE connector is used to connect the DSU to a 56K DDS circuit or LADS.  This connector is an RJ-48
(keyed) jack on the back panel of the unit.

Содержание MT56DSU-S

Страница 1: ...MT56DSU S Syncronous 56K bps Data Service Unit User Guide...

Страница 2: ...n of Multi Tech Systems Inc to notify any person or organization of such revisions or changes Revision Date Description A 12 30 2003 Initial release of MT56DSU S User Manual on CD Trademarks MultiTech...

Страница 3: ...Introduction 11 2 2 Front Panel 11 2 3 Back Panel 12 2 3 1 POWERConnector 12 2 3 2 RS232Connector 12 2 3 3 LINEConnector 12 2 4 Switch Settings 13 2 5 Shunts 14 Chapter 3 Unpacking Setup 15 3 1 Introd...

Страница 4: ...ernationalDistributors 27 5 2 4 ReplacementParts 27 5 3 Technical Support 27 5 4 Internet Site 27 Appendix 28 Appendix A Application Examples 29 Introduction 29 Local Area Data Set Application 29 DDSP...

Страница 5: ...Chapter 1 Introduction...

Страница 6: ...ption Chapter 3 Unpacking and Setup provides unpacking safety warnings setup procedures and how to change the shunt from the default RS232 position to the V 35 position Chapter 4 Diagnostic Testing ex...

Страница 7: ...d a CSU Channel Service Unit are typically connected to provide the interface between DTE data terminal equipment and a DDS or other four wire network The DSU processes serial synchronous digital data...

Страница 8: ...Multi Tech DSU CSU provides the following features Supports direct connection to the DATAPHONE Digital Data Service DDS or compatible network Standard EIA 232 D and V 35 interfaces on the data port D...

Страница 9: ...Hz 2 Watts Temperature 32 to 120 F 0 to 50 C Humidity 20 to 90 non condensing Dimensions 1 H x 4 125 W x 5 5 D 2 5 cm H x 10 8 cm W x 14 2 cm D Weight 8 oz 224 g Certification FCC Part 15 Class B FCC...

Страница 10: ...Chapter 2 Front Back Panel Descriptions...

Страница 11: ...ing frames and line status Figure 2 1 Front Panel TD Transmit Data TD LED blinks when data is being transmitted on for a space and off for a mark RD Receive Data RD LED blinks when data is being recei...

Страница 12: ...nsformer plugs directly into an AC outlet 2 3 2 RS232 Connector The RS232 Data connector is used to connect the DSU to a sync device such as multiplexers routers or legacy equipment such as cluster co...

Страница 13: ...d when viewed from the front as in Figure 2 3 The DIP switch functions are described in the following table 1 2 3 4 5 6 7 8 DIP Switch Figure 2 3 Switch Settings Table 2 1 Switch Settings Switch Mode...

Страница 14: ...ess There are two shunt positions in the middle left side of the printed circuit board that configure the data port for either RS232 or V 35 operation The shunt positions are shown in Figure 2 3 V 35...

Страница 15: ...Chapter 3 Unpacking Setup...

Страница 16: ...ts final location and verify the signal levels EIA 232 D or ITU T V 35 for the data port and connect your cables phone lines and power supply 3 3 Telecom Safety Warnings 1 Never install telephone wiri...

Страница 17: ...e details If the DTE device has an EIA 232 D interface a standard RS232 straight thru cable can be used POWER LINE RS232 To Power Outlet To DTE Device To Line Jack Figure 3 1 Back Panel Connections 2...

Страница 18: ...oid any chance of electric shock 1 Unplug the power cord 2 The enclosure consists of two halves Using a Phillips screwdriver remove the two screws from the bottom of the unit Remove the top half 3 Car...

Страница 19: ...Chapter 4 Diagnostics...

Страница 20: ...eck the remote far end transmitting equipment If the remote equipment is transmitting properly contact your telephone company If the Telco is required to perform remote tests the channel will be tempo...

Страница 21: ...ester Remote DSU In Line Loopback Test Mode Figure 4 2 Line Loopback Test Diagram 4 1 3 DSU Loopback Test This test lets you verify proper DSU operation by matching a transmitted signal to the looped...

Страница 22: ...emble one Refer to Appendix B for instructions on building the Back to Back cable 2 Plug the cable into each DSU s Line jack 3 On the good DSU set DIP switch 3 to the down position 4 Set one DSU to in...

Страница 23: ...Chapter 5 Service Warranty...

Страница 24: ...IRCUMSTANCES WILL ITS LIABILITY EXCEED THE PRICE FOR DEFECTIVE PRODUCTS 5 1 2 U S and Canadian Customers In the event that service is required products may be shipped freight prepaid to our Mounds Vie...

Страница 25: ...description of the problem a return shipping address must have street address not P O Box your telephone number and if the product is out of warranty a check drawn on a U S bank or your company s purc...

Страница 26: ...plus materials basis 5 2 2 Repair Procedures for International Customers Your original point of purchase Reseller may offer the quickest and most economical repair option for your Multi Tech product Y...

Страница 27: ...t Multi Tech Systems has an excellent staff of technical support personnel available to help you get the most out of your Multi Tech product If you have any questions about the operation of this unit...

Страница 28: ...Appendix...

Страница 29: ...s of AWG 26 wire at 56 Kbps or longer for subrate applications The figure below depicts a typical Local Area Data Set application DTE Up to 3 miles of AWG 26 wire 56 Kbps DTE DSU DSU Requires two pair...

Страница 30: ...ntrolled by the DTE Multipoint DDS provides communication between a control station and two or more remote stations All data transmitted by the control station is sent to each remote station For data...

Страница 31: ...re B 1 Connector DESCRIPTION This connector ties the MT56DSU S to the DDS Network The RJ 48 connector is keyed for proper insertion of a keyed RJ 48 plug PIN IDENTIFICATION Pin Description Destination...

Страница 32: ...e MT56DSU S to the DTE The DB25S connector has the following pinout configuration PIN IDENTIFICATION Pin Description Signal 1 Chassis Ground 2 Transmit Data SD 3 Received Data RD 4 Request To Send RTS...

Страница 33: ...to a MT56DSU S the internal shunt has to be moved to the V 35 position The V 35 interface for the DB25 connector has the following pinout configuration PIN IDENTIFICATION Pin Description 1 Chassis Gr...

Страница 34: ...rison to the original signal sent You can order this cable 45640100 from Multi Tech or build one using the instructions below Refer to Chapter 4 for test procedures SCHEMATIC RJ48S 1 2 3 4 5 6 7 8 6 R...

Страница 35: ...sing the instructions below Refer to Chapter 4 for test procedures SCHEMATIC RJ48S 1 2 3 4 5 6 7 8 7 RJ48S 8 7 6 5 4 3 2 1 Figure B 8 BUILD INSTRUCTIONS 1 Strip cable installation 3 4 2 Strip wires 1...

Страница 36: ...he customer as soon as possible Also you will be advised of your right to file a complaint with the FCC if you believe it is necessary 5 The telephone company may make changes in its facilities equipm...

Страница 37: ...ted to the facilities of the local telecommunications company The equipment must also be installed using an acceptable method of connection The customer should be aware that compliance with the above...

Страница 38: ...S000327A...

Отзывы: