PN 88300150
4/3/01
37
&I1
Resets the Inactivity Timer when data is received from the other modem.
&I2
Resets the Inactivity Timer when the modem transmits.
&I3
Resets the Inactivity Timer when data is either transmitted or received.
The factory default setting is &I0.
*C
Caller ID Detection
Note:
The Caller ID detection feature is optional.
The Call Traffic window will display the phone number and the name of an individual that
dials in on a phone line that supports Caller ID. The call must not be answered before the
second ring to receive this information. This feature requires Caller ID phone lines, and a
firmware level of 1.10a or greater. The Caller ID firmware is inactive by default, but can be
activated via the modem AT command, *C1.
*C0
Turns off Caller ID detection.
*C1
Turns on Caller ID detection for the MultiCommManager.
*C2
Is storable in MT2834MR memory and turns on Caller ID reporting on the serial port
by the MultiCommManager.
*C3
Lets you see the last Caller ID’s number.
The factory default setting is *C0.
Note:
The *C command is not used in the MT2834MRI or the MT2834MRK.
&CD
Cleardown at Disconnect
The &CD command is used for control of cleardown at disconnect in V.32, V.32bis and V.34
modes.
The &CD command enables or disables execution of a cleardown (a “Cleardown” is an ITU
standard signal recognized by ITU-compatible modems). A cleardown should make a
disconnect by the remote modem easier to detect and a successful subsequent reconnect
more likely.
A cleardown usually adds 1-2 seconds to the time it takes for the modem to go on-hook after
the disconnect; if this causes a problem, use the &CD1 command to disable the cleardown
function.
&CD0
Enable cleardown on disconnect.
&CD1
Disable cleardown on disconnect.
The factory default setting is &CD0.
*H
Busy Out After Disconnect
With the *H1 command, the MT2834MR will stay busy until configuration from the
MultiCommManager dedicated management console has finished. If no configuration option
is set on the dedicated management console, the MT2834MR will stay busy for ten seconds
after disconnect.
*H0
Busy out after disconnect disabled.
*H1
Busy out after disconnect enabled.
The factory default setting is *H0.
*R
Callback Ring
Содержание MT2834MR