OEM INTEGRATION
QuickCarrier™ USB-E MT100UCC-EV3 Developer Guide
13
#907
FUMO -Session started
If application sees one of these indications it should not attempt to issue commands, attempt data connection, or
reset device until the OMA process is complete as indicated by additional #9XX OMA success or failure indications
below.
If the device is in a data connection at the time a Network Initiated PRL, DC, or FUMO update alert message is
received from Sprint, the radio may close the data connection and start OMA-DM process with a #9xx indication.
When this occurs the application should not attempt to issue AT commands, attempt to start data connection
again, or reset device in an attempt to regain control. Application should wait for a #9xx indication the process has
completed before proceeding.
Be aware after the HFA process is successfully completed the radio will be reset. The radio may also reset after
other OMA functions.
Sprint #9XX OMA Unsolicited Indications
#900
DM Client Ready
Sprint Hands Free Activation HFA Notifications
#901
HFA Attempt #
#902
HFA Countdown Timer (seconds)
#904
HFA Started
#911
HFA Error - credential error
#912
HFA Error - unreachable server
#913
HFA Error - network error
#914
HFA Done - HFA success
#922
HFA Done - No profile received
#923
HFA Error – ETC
#924
HFA Cancelled
#DREL
Data session release
Sprint Network Initiated Device Configuration (NIDC) or Client Initiated Device Configuration (CIDC)
#906
DC - Session started
#911
DC - Error - credential error
#912
DC - Error - unreachable server
#913
DC - Error - network error
#915
DC - Error - update fails for other reasons
#918
DC - Done - success
#924
DC - Cancelled - no profile received
#DREL