background image

ENVIRONMENTAL NOTICES

Dragonfly

TM

MTQ-LEU7 Device Guide

25

Chapter 8 – Environmental Notices

Waste Electrical and Electronic Equipment Statement

Note:

This statement may be used in documentation for your final product applications.

WEEE Directive

The WEEE Directive places an obligation on EU-based manufacturers, distributors, retailers, and importers to take-
back electronics products at the end of their useful life. A sister directive, ROHS (Restriction of Hazardous
Substances) complements the WEEE Directive by banning the presence of specific hazardous substances in the
products at the design phase. The WEEE Directive covers all MultiTech products imported into the EU as of August
13, 2005. EU-based manufacturers, distributors, retailers and importers are obliged to finance the costs of recovery
from municipal collection points, reuse, and recycling of specified percentages per the WEEE requirements.

Instructions for Disposal of WEEE by Users in the European Union

The symbol shown below is on the product or on its packaging, which indicates that this product must not be
disposed of with other waste. Instead, it is the user's responsibility to dispose of their waste equipment by handing
it over to a designated collection point for the recycling of waste electrical and electronic equipment. The separate
collection and recycling of your waste equipment at the time of disposal will help to conserve natural resources
and ensure that it is recycled in a manner that protects human health and the environment. For more information
about where you can drop off your waste equipment for recycling, please contact your local city office, your
household waste disposal service or where you purchased the product.

July, 2005

REACH Statement

Registration of Substances

Multi-Tech Systems, Inc.

confirms that none of its products or packaging contain any of the Substances of Very

High Concern (SVHC) on the REACH Candidate List, in a concentration above the 0.1% by weight allowable limit

The latest

197

substances restricted per the REACH Regulation were

last updated January 2019

. Refer to the

following for the most current candidate list of substances:

http://echa.europa.eu/candidate-list-table

.

Restriction of the Use of Hazardous Substances (RoHS)

Multi-Tech Systems, Inc.

Certificate of Compliance

2015/863

Содержание Dragonfly MTQ-LEU7

Страница 1: ...Dragonfly TM MTQ LEU7 Device Guide...

Страница 2: ...T OVER A CELLULAR COMMUNICATIONS NETWORK WILL BE UNINTERRUPTED TIMELY SECURE OR ERROR FREE NOR DOES MULTITECH WARRANT ANY CONNECTION OR ACCESSIBILITY TO ANY CELLULAR COMMUNICATIONS NETWORK MULTITECH W...

Страница 3: ...Current Ratings 12 Power Draw 12 MTQ LEU7 B02 12 Chapter 3 Getting Started with the MTQ LEU7 B02 13 Installing a SIM Card on a DragonFly 13 Device Drivers 13 USB Cable Recommendations 13 Communication...

Страница 4: ...Australia 24 Chapter 8 Environmental Notices 25 Waste Electrical and Electronic Equipment Statement 25 WEEE Directive 25 Instructions for Disposal of WEEE by Users in the European Union 25 REACH State...

Страница 5: ...Dragonfly TM MTQ LEU7 Device Guide 5 Connection Manager is not working and a device connected to the computer is not detected 34 Connection Manager displays Device Error status for a serial device 34...

Страница 6: ...ide Provides information on using the developer board with the MTQ S000610 Quectel EG9x AT Commands Manual USB Installation Guides and other related manuals Multiple documents listing AT Commands USB...

Страница 7: ...PRODUCT OVERVIEW Dragonfly TM MTQ LEU7 Device Guide 7 MTQ LEU7 B02 Mechanical Drawing...

Страница 8: ...8 LED One link status Speed Data Speed LTE FDD Up to 150 Mbps downlink 50 Mbps uplink WCDMA Up to 384 Kbps downlink 384 Kbps uplink GSM Up to 296 Kbps downlink 236 8 Kbps uplink Interface USB Interfac...

Страница 9: ...carriers Radio performance may be affected by temperature extremes Device has been tested up to 85 C UL Recognized 85 C 40 Pin Connector Definitions MTQ LEU7 B02 Pin Signal Name Logic Level Voltage1...

Страница 10: ...8V O This output is generated by the radio 28 GND GND GND Ground 29 RADIO_RTS 0 3 3V 3 3V I Request to send flow control 30 RADIO_DSR 0 3V 3 3V O Data set ready 31 RADIO_DTR 0 3 3V 3 3V I DTE ready 32...

Страница 11: ...ctrical Characteristics Parameter Conditions Minimum Volts Maximum Volts Digital signal input low level CMOS port IIO 8 mA 0 3 0 9 Digital signal input high level CMOS port IIO 8 mA 2 1 5 5 Output low...

Страница 12: ...r output pins 25 mA Power Draw MTQ LEU7 B02 Radio Protocol Average Measured Current at Max Power mA 1 TX Pulse2 Average Amplitude Current for Peak Current for HSDPA LTE mA Total Inrush Charge3 Measure...

Страница 13: ...r to the Windows USB Drivers Installation Guide see Documentation in Chapter 1 for more details For driver installation instructions for Quectel radios using Linux refer to the Linux USB Driver User G...

Страница 14: ...blish serial communication using Multitech developer board MTUDK2 See the Universal Developer Kit 2 0 Developer Guide PN S000610 for more information Powering Down The Device CAUTION Failing to proper...

Страница 15: ...TQ LEU7 B02 Dragonfly TM MTQ LEU7 Device Guide 15 Low Power Options See Powering Down the Device for the lowest power consumption Refer to AT QSCLK in the AT Command Reference Guide for details on sle...

Страница 16: ...facturer Wieson Description LTE Antenna with SMA Male Connector Model Number GY115IE002 001 MultiTech ordering information Model Quantity ANLTE4 1HRA 1 ANLTE4 2HRA 2 ANLTE4 10HRA 10 ANLTE4 50HRA 50 An...

Страница 17: ...ice to determine which antenna to connect to which U FL connector on the device Connecting an Antenna through the Developer Board Connectors To connect an antenna to the device through the developer b...

Страница 18: ...n AT command to turn antenna diversity on and off When antenna diversity is on and a like or similar antenna is installed on both radio connectors the radio automatically chooses the antenna with the...

Страница 19: ...fly TM MTQ LEU7 Device Guide 19 Diversity and Power Draw There are no significant power draw differences Important You must deploy with two antennas unless your carrier has authorized you to deploy wi...

Страница 20: ...ender legal action or both Switch OFF your wireless device when around gasoline or diesel fuel pumps and before filling your vehicle with fuel Switch OFF your wireless device in hospitals and any othe...

Страница 21: ...cardiac pacemakers and defibrillators from cellular devices This test method is part of the Association for the Advancement of Medical Instrumentation AAMI standard This standard allows manufacturers...

Страница 22: ...device or harm to users Do not use this device in explosive or hazardous environments unless the model is specifically approved for such use The device may cause sparks Sparks in explosive areas could...

Страница 23: ...ification The MultiTech model identification allows the carrier to verify the modem as one of its approved models This information is located on the modem s label below the bar code Labels This device...

Страница 24: ...equipment and telecommunications terminal equipment and the mutual recognition of their conformity MultiTech declares that this device is in compliance with the essential requirements and other relev...

Страница 25: ...t this product must not be disposed of with other waste Instead it is the user s responsibility to dispose of their waste equipment by handing it over to a designated collection point for the recyclin...

Страница 26: ...rcury Hg 100 PPM Cadmium Cd 100 PPM Hexavalent Chromium Cr 6 1000 PPM Polybrominated Biphenyl PBB 1000 PPM Polybrominated Diphenyl Ethers PBDE 1000 PPM Bis 2 Ethylhexyl phthalate DEHP 1000 ppm Benzyl...

Страница 27: ...the appropriate drivers are installed can cause the connection to fail To install Connection Manager and the device drivers 1 Go to https www multitech com support connection manager 2 Click Connectio...

Страница 28: ...when the installation is finished After the drivers are installed you need to restart your computer if prompted by Windows If using a USB device you can connect the device to the carrier s network wit...

Страница 29: ...g another model may cause your device to work incorrectly or fail f Select your COM port then click Next g Click Finish h Go to Device Manager Modems and confirm that the device is added 6 To verify t...

Страница 30: ...eep alive feature is enabled the Connection Manager s Main tab displays the keep alive check status and when the last ping response was received b If your device supports dual carriers switch the firm...

Страница 31: ...d to the carrier s network When connection to the network is established the last signal strength value is displayed View the details for the current connection on the Details tab 6 To disconnect the...

Страница 32: ...ect or Disconnect Signal strength bars and percentage indicator only when connection to the carrier s network is established Note The signal strength is displayed for a serial device only when the dev...

Страница 33: ...the Host to ping box Connection Monitor will send periodic pings to the host If the keep alive feature fails Connection Manager will automatically reconnect The MNO firmware list If your device suppo...

Страница 34: ...connected device because the required drivers are not installed The most likely cause is that Install the modem drivers was not checked during the installation Uninstall and re install Connection Man...

Страница 35: ...ice connecting to carrier s network with Connection Manager 30 maintenance 22 device drivers installation for use with Connection Manager 27 diversity 18 documentation 6 E electrical characteristics 1...

Страница 36: ...INDEX 36 Dragonfly TM MTQ LEU7 Device Guide static 20 s curit interf rences RF 20 T troubleshooting Connection Manager 33 U U FL 17 user responsibility 22 V vehicle safety 21...

Отзывы: