103
Chapter 7 - Troubleshooting
7.9 Composite Link Statistics
Table 7-9. Composite Link Statistics
Step
Procedure
1
Toggle DIP switch position 3 to the down (closed) position to enable the command port.
2
Connect a terminal or PC running communications software to the DATA/COMMAND
connector on the back panel of the DataTalker.
Note:
Any cables connected to the computer should be shielded to reduce interference.
3
Apply power to the DataTalker.
4
Apply power to the terminal or PC. Run the PC’s communications software in terminal mode
and press ENTER twice to establish communications with the DataTalker. The Main Menu
appears:
Main Menu
1 - Configurations
2 - Statistics
3 - Reset Options
4 - Diagnostics
5 - Exit Command Mode
6 - QUICK SETUP
Selection : _
5
Enter 2 and press ENTER. The Statistics menu is displayed:
Statistics
1 - View Composite Link Statistics
2 - Clear Composite Link Statistics
M - Main Menu
P - Previous Menu
Selection : _
6
Enter 1 and press ENTER to view the composite link statistics:
Composite Link Statistics
Elasped Time : 00 Days 00 Hours 00
Minutes
Data Blocks Transmitted : 0
Data Blocks Retransmitted : 0
Data Blocks Received : 0
Receive Block Errors : 0
Voice/Fax Blocks Transmitted : 0
Voice/Fax Blocks Received : 0
Link Alarms : 0
Remote Downs : 0
Содержание DataTalker DT101
Страница 6: ......
Страница 7: ...Chapter 1 Introduction and Description...
Страница 19: ...Chapter 2 Configuration...
Страница 35: ...Chapter 3 Front and Rear Panel Descriptions...
Страница 43: ...Chapter 4 Unpacking and Configuration...
Страница 54: ...54 DataTalker Owner s Manual...
Страница 55: ...Chapter 5 Installation...
Страница 64: ...64 DataTalker Owner s Manual...
Страница 65: ...Chapter 6 Menus...
Страница 87: ...Chapter 7 Troubleshooting...
Страница 110: ...110 DataTalker Owner s Manual...
Страница 111: ...Chapter 8 Warranty Service and Tech Support...
Страница 116: ...116 DataTalker Owner s Manual...
Страница 117: ...Appendixes...