MT3334HD8 User Guide
86
CommPlete Communications Server
Changing the Passwords
1.
Establish a remote configuration link with the remote modem as described above.
2.
Type
AT#IMULTI-TECH
(or
AT#I
xxxxxx
if you have replaced the
MULTI-TECH
password with
xxxxxx
) and press E
NTER
. The modem responds with
OK
if the login password is correct, and
ERROR
if it is wrong.
3.
Type
AT#SMODEMSETUP
(or
AT#S
yyyyyy
if you have replaced the MODEMSETUP password
with
yyyyyy
) and press E
NTER
. The modem responds with
OK
if the setup password is correct, and
ERROR
if it is wrong.
4.
To change the login password, type
AT#I=
xxxxxx
, where
xxxxxx
stands for the password, and
press E
NTER
. The password may include any keyboard characters, but must be six to ten characters long.
The modem responds with
OK
.
5.
To change the setup password, type
AT#S=
yyyyyy
, where
yyyyyy
stands for the password, and
press E
NTER
. The password may include any keyboard characters, but must be six to ten characters
long. The modem responds with
OK
.
6.
The new passwords are saved automatically. You may now either enter more AT commands or exit
remote configuration with
ATO<CR>
. The next time you remotely configure the modem you must
use the new setup password.
Note:
Passwords are case sensitive. The next time you enter the password, it must be in the same case as
you set it up.
Changing the Remote Escape Character
To increase security, you may wish to change the remote modem’s remote configuration escape character.
The remote configuration escape character is stored in register
S13
. The factory default is 37, which is the
ASCII code for the percent character (%). Setting
S13
to 0 (zero) will disable remote configuration
entirely—but if you do this remotely, you won’t be able to change it back remotely!
1.
Establish a remote configuration link with the remote modem as described above.
2.
Type
ATS13=
n
, where
n
is the ASCII code for the new remote configuration escape character, then
press E
NTER
.
3.
Save the new value by typing
AT&W
and pressing E
NTER
.
4.
Type
ATO<CR>
, then
1
, to exit remote configuration.
Содержание CommPlete MT3334HD8
Страница 1: ...MT3334HD8 Modem User Guide ...
Страница 7: ...CommPlete Communications Server 1 1 Introduction ...
Страница 13: ...CommPlete Communications Server 7 2 Installation ...
Страница 16: ......
Страница 17: ...CommPlete Communications Server 11 3 AT Commands ...
Страница 50: ...MT3334HD8 User Guide 44 CommPlete Communications Server ...
Страница 51: ...CommPlete Communications Server 45 4 S Registers ...
Страница 59: ...CommPlete Communications Server 53 5 Testing the MT3334HD8 ...
Страница 64: ......
Страница 65: ...CommPlete Communications Server 59 6 Warranty Service and Technical Support ...
Страница 72: ...MT3334HD8 User Guide 66 CommPlete Communications Server ...
Страница 73: ...CommPlete Communications Server 67 Appendixes ...
Страница 93: ...CommPlete Communications Server 87 Index ...
Страница 99: ......
Страница 100: ...P N 82063701 ...