background image

GETTING STARTED

Dragonfly

Nano MTQN-MNG3-B01 Device Guide

21

To properly power down the cellular radio, use one of the following methods:

1.

Issue command AT+CPWROFF then either wait 40s or until 1.8v from the cellular radio goes low.
Processor pin PC5 (Mbed pin name MON_1V8) has 1.8v from the radio connected to it.

2.

Hold pin processor PE_4 (Mbed pin name RADIO_ONOFF or MDMPWRON) low for at least 1.5s. 1.8v
from the radio should go low.

3.

If neither of the above two options are successful, an emergency power down can be performed by
holding processor pin PF_3 (mbed pin name RADIO_RESET) low for 10s. As always, power down is
confirmed by monitoring 1.8v from the radio.

Configuring u-blox Cellular Radio

This MNG3 device uses a cellular radio that can operate on different carrier networks (not simultaneously).

You must configure your module based on your carrier network and application. This includes setting the
applicable MNO profile (based on carrier), RAT (type of technology you wish to use such as Cat M1), and LTE bands
intended for the application device within regulatory compliance. The module is not intended be used in the
factory-default setting.

Depending on your MNO profile, certain elements may or may not be available. Refer to the table for details.

Updates to MNO profile version

:

Note 1: +CPSMS

Note 2: +CEDRXS

Note 3: +URAT

Note 4: +UBANDMASK

If your carrier network is not on the supported list of MNOs, you must set to Cat M1 mode and follow the
instructions per that scenario below.

The MNG3 model has regulatory approval to operate in the EU/UK. We continue to work for approval on other
networks. Refer to the Sara-R4/N4 series AT Commands Manual for the list of supported MNOs and other details.

Note:

If your device is on +UMNOPROF: 0 (SW default), you do not have a network defined yet and must

set one.

To set or switch carrier networks:

1.

Deregister the module from the network or perform an AT+CFUN=0 cycle:

AT+CFUN=0

Содержание 94558240LF

Страница 1: ...Dragonfly Nano MTQN MNG3 B01 Device Guide...

Страница 2: ...RANT THAT THE TRANSMISSION OF DATA BY A PRODUCT OVER A CELLULAR COMMUNICATIONS NETWORK WILL BE UNINTERRUPTED TIMELY SECURE OR ERROR FREE NOR DOES MULTITECH WARRANT ANY CONNECTION OR ACCESSIBILITY TO A...

Страница 3: ...Operating Conditions 10 Absolute Maximum Ratings 10 Nominal Ratings 11 Power Draw 12 Chapter 4 Antennas 13 Antenna 13 Antenna Specifications 13 Chapter 5 Safety Information 14 Handling Precautions 14...

Страница 4: ...tatement 26 Registration of Substances 26 Information on HS TS Substances According to Chinese Standards in Chinese 27 Information on HS TS Substances According to Chinese Standards 28 Chapter 10 Usin...

Страница 5: ...de Provides information for using the developer board with the MTQN S000610 ST Microcontroller Data Sheet Data sheet for processor STM32L471QG https www st com en microcontrollers stm32l471qg htm l 02...

Страница 6: ...MECHANICAL DRAWINGS 6 Dragonfly Nano MTQN MNG3 B01 Device Guide Chapter 2 Mechanical Drawings MTQN MNG3 B01...

Страница 7: ...Board Host Processor Cortex M4 STM32L471QG 1 Mbyte Flash and 128 Kbyte SRAM B01 I O 1 x UART 1 x HS USB 2 x SPI 2 x I2C up to 9 analog inputs and up to 29 digital input output SMS Mobile Terminate Mob...

Страница 8: ...l Drawings for more information Here are some standoffs that can be used with this product Recommended Parts Manufacturer Part Part Number PEM Penn Engineering Manufacturing Surface Mount Standoff SMT...

Страница 9: ..._ can also be used as Digital In and Digital Out interfaces Hardware and Software Pinout Information Refer to both the hardware and software pinout information on the Multitech Developer Resources sit...

Страница 10: ...n VDD VDDA VDDIO2 4 03 4 V Input voltage on TT_xx pins VSS 0 3 4 0 V Input voltage on BOOT0 pin VSS 9 0 V Input voltage on any other pins VSS 0 3 4 0 V VDDx Variations between power pins Variations be...

Страница 11: ...ected current on PA4 PA5 IINJ PIN Total injected current sum of all I Os and control pins 5 5 0 25 Data taken from STM32L471QG processor datasheet 1 All main power VDD VDDA VDDIO2 VBAT and ground VSS...

Страница 12: ...Card External DC Supply used GSM850 7 5 28 N A N A N A 5 Volts with Unit In Dev Card LTE 8 5 42 180 680 0 245 5 Volts USB only no Dev card LTE 292 58 238 864 0 281 3 3 Volts with Unit in Dev Card Ext...

Страница 13: ...a with SMA Male Connector Model Number GY115IE002 001 MultiTech ordering information Model Quantity ANLTE4 1HRA 1 ANLTE4 2HRA 2 ANLTE4 10HRA 10 ANLTE4 50HRA 50 Antenna Specifications Category Descript...

Страница 14: ...around gasoline or diesel fuel pumps and before filling your vehicle with fuel Switch OFF your wireless device in hospitals and any other place where medical equipment may be in use S curit relative...

Страница 15: ...rillators are safe from cellular device EMI The FDA continues to monitor cellular devices for interactions with other medical devices If harmful interference occurs the FDA will assess the interferenc...

Страница 16: ...specifically approved for such use The device may cause sparks Sparks in explosive areas could cause explosion or fire and may result in property damage severe injury and or death Do not expose your...

Страница 17: ...platform and operating system for embedded devices using the ARM Cortex M microcontrollers The Mbed website provides free software libraries hardware designs and online tools for rapid prototyping of...

Страница 18: ...stm32l471qg html Communications Flow MTQN MNG3 B01 The MTQN MNG3 B01 provides full UART from the cellular radio to the processor as well as the user application Model B01 provides a direct USB interf...

Страница 19: ...nector to avoid enumeration or power issues Use a high speed USB cable that is as short as possible Use a well shielded cable with at least 24 AWG wire pair for power ground and 28 AWG wire pair for d...

Страница 20: ...Down The Cellular Radio section 2 PSM mode AT CPSMS command 3 eDRX AT CEDRXS command 4 Device functionality AT CEDRXS command Power to Cellular Radio After power down RADIO_PWR can be configured as a...

Страница 21: ...network and application This includes setting the applicable MNO profile based on carrier RAT type of technology you wish to use such as Cat M1 and LTE bands intended for the application device within...

Страница 22: ...arately before UBANDMASK AT CFUN 0 AT UMNOPROF 0 AT CFUN 15 AT CFUN 0 AT CGDCONT AT UBANDMASK AT CFUN 15 To configure the supported radio bands Use the UBANDMASK command if your MNO is not listed by t...

Страница 23: ...on The MultiTech model identification allows the carrier to verify the modem as one of its approved models This information is located on the modem s label below the bar code Example Labels Note Actua...

Страница 24: ...rective 2011 65 EU on the restriction of the use of certain hazardous substances in electrical and electronic equipment and Council Directive 2014 53 EU on radio equipment and telecommunications termi...

Страница 25: ...obliged to finance the costs of recovery from municipal collection points reuse and recycling of specified percentages per the WEEE requirements Instructions for Disposal of WEEE by Users in the Europ...

Страница 26: ...halate DEHP 1000 ppm Benzyl butyl phthalate BBP 1000 ppm Dibutyl phthalate DBP 1000 ppm Diisobutyl phthalate DIBP 1000 ppm Environmental considerations Moisture Sensitivity Level MSL 1 Maximum Solderi...

Страница 27: ...Chinese MII EIP 39 RoHS Multi Tech Systems Inc TS HS PB Hg CD CR6 PBB PBDE O O O O O O X O O O O O X O O O O O O O O O O O O O O O O O ICs O O O O O O O O O O O O X O O O O O O O O O O O O O O O O O...

Страница 28: ...ed Biphenyl PBB Polybrominat ed Diphenyl Ether PBDE Printed Circuit Boards O O O O O O Resistors X O O O O O Capacitors X O O O O O Ferrite Beads O O O O O O Relays Opticals O O O O O O ICs O O O O O...

Страница 29: ...e appropriate drivers are installed can cause the connection to fail To install Connection Manager and the device drivers 1 Go to https www multitech com support connection manager 2 Click Connection...

Страница 30: ...r computer if prompted by Windows If using a USB device you can connect the device to the carrier s network with Connection Manager Refer to Connecting a Device If using a serial device you need to se...

Страница 31: ...cting another model may cause your device to work incorrectly or fail f Select your COM port then click Next g Click Finish h Go to Device Manager Modems and confirm that the device is added 6 To veri...

Страница 32: ...pings to a host check Enable keep alive and enter the IP address or host name to ping in the Host to ping box For example you can enter the host name google com or IP address 8 8 8 8 If the keep aliv...

Страница 33: ...strength percentage and bars The statistics on connection speeds and traffic are available only during a current connection session Note For serial modems the signal strength is available only when th...

Страница 34: ...following Status of device connection Searching Connecting Connected Disconnecting or Disconnected The action button which changes according to the current device connection status Detect Connect or D...

Страница 35: ...Connection tab The Connection tab displays the following The carrier provided connection settings The Enable keep alive check box Check this box to monitor connectivity to the Internet Check Enable ke...

Страница 36: ...onnected to the PC and that the correct USB cable is in use Connection Manager is not working and a device connected to the computer is not detected Connection Manager cannot detect a connected device...

Страница 37: ...verview 29 Settings tab 34 Terminal tab 34 troubleshooting 36 uninstalling 33 D device connecting to carrier s network with Connection Manager 32 device drivers installation for use with Connection Ma...

Отзывы: