background image

DRAGONFLYTM DEVICE GUIDE

2

Dragonfly

TM

MTQ-LNA7 Device Guide

Dragonfly

TM

Device Guide

Models: MTQ-LNA7-B02

Part Number: S000749 Rev 1.4

Copyright

This publication may not be reproduced, in whole or in part, without the specific and express prior written permission signed by an executive officer of
Multi-Tech Systems, Inc. All rights reserved.

Copyright © 2022 by Multi-Tech Systems, Inc.

Multi-Tech Systems, Inc. makes no representations or warranties, whether express, implied or by estoppels, with respect to the content, information,
material and recommendations herein and specifically disclaims any implied warranties of merchantability, fitness for any particular purpose and non-
infringement.

Multi-Tech Systems, Inc. reserves the right to revise this publication and to make changes from time to time in the content hereof without obligation of
Multi-Tech Systems, Inc. to notify any person or organization of such revisions or changes.

Trademarks and Registered Trademarks

MultiTech, and the MultiTech logo, MultiConnect, and Dragonfly are trademarks or registered trademarks of Multi-Tech Systems, Inc. All other products
and technologies are the trademarks or registered trademarks of their respective holders.

Legal Notices

The MultiTech products are not designed, manufactured or intended for use, and should not be used, or sold or re-sold for use, in connection with
applications requiring fail-safe performance or in applications where the failure of the products would reasonably be expected to result in personal injury or
death, significant property damage, or serious physical or environmental damage. Examples of such use include life support machines or other life
preserving medical devices or systems, air traffic control or aircraft navigation or communications systems, control equipment for nuclear facilities, or
missile, nuclear, biological or chemical weapons or other military applications (“Restricted Applications”). Use of the products in such Restricted
Applications is at the user’s sole risk and liability.

MULTITECH DOES NOT WARRANT THAT THE TRANSMISSION OF DATA BY A PRODUCT OVER A CELLULAR COMMUNICATIONS NETWORK WILL BE
UNINTERRUPTED, TIMELY, SECURE OR ERROR FREE, NOR DOES MULTITECH WARRANT ANY CONNECTION OR ACCESSIBILITY TO ANY CELLULAR
COMMUNICATIONS NETWORK. MULTITECH WILL HAVE NO LIABILITY FOR ANY LOSSES, DAMAGES, OBLIGATIONS, PENALTIES, DEFICIENCIES, LIABILITIES,
COSTS OR EXPENSES (INCLUDING WITHOUT LIMITATION REASONABLE ATTORNEYS FEES) RELATED TO TEMPORARY INABILITY TO ACCESS A CELLULAR
COMMUNICATIONS NETWORK USING THE PRODUCTS.

The MultiTech products and the final application of the MultiTech products should be thoroughly tested to ensure the functionality of the MultiTech
products as used in the final application. The designer, manufacturer and reseller has the sole responsibility of ensuring that any end user product into
which the MultiTech product is integrated operates as intended and meets its requirements or the requirements of its direct or indirect customers.
MultiTech has no responsibility whatsoever for the integration, configuration, testing, validation, verification, installation, upgrade, support or maintenance
of such end user product, or for any liabilities, damages, costs or expenses associated therewith, except to the extent agreed upon in a signed written
document. To the extent MultiTech provides any comments or suggested changes related to the application of its products, such comments or suggested
changes is performed only as a courtesy and without any representation or warranty whatsoever.

Contacting MultiTech

Country

Sales

Support

Europe, Middle East,
Africa:

[email protected]

+(44) 118 959 7774

[email protected]

+(44) 118 959 7774

U.S., Canada, all
others:

[email protected]

(800) 328-9717 or (763) 785-
3500

[email protected]

(800) 972-2439 or (763) 717-
5863

Website

www.multitech.com

Knowledge Base

For immediate access to support information and resolutions for MultiTech products, visit

http://www.multitech.com/kb.go

.

Support Portal

To create an account and submit a support case directly to our technical support team, visit:

https://support.multitech.com

.

Warranty

To read the warranty statement for your product, visit

https://www.multitech.com/legal/warranty

.

World Headquarters

Multi-Tech Systems, Inc.

2205 Woodale Drive, Mounds View, MN 55112

Содержание 94558222LF

Страница 1: ...Dragonfly TM MTQ LNA7 Device Guide...

Страница 2: ...THE TRANSMISSION OF DATA BY A PRODUCT OVER A CELLULAR COMMUNICATIONS NETWORK WILL BE UNINTERRUPTED TIMELY SECURE OR ERROR FREE NOR DOES MULTITECH WARRANT ANY CONNECTION OR ACCESSIBILITY TO ANY CELLUL...

Страница 3: ...istics 12 Input Output Current Ratings 13 Power Draw MTQ LNA7 B02 13 Chapter 3 Getting Started 15 Installing a SIM Card on a DragonFly 15 Device Drivers 15 USB Cable Recommendations 15 Communications...

Страница 4: ...Canada Class B Notice 27 Canadian Limitations 28 Industry Canada 29 Chapter 8 Environmental Notices 31 Waste Electrical and Electronic Equipment Statement 31 WEEE Directive 31 Instructions for Disposa...

Страница 5: ...ce is not detected No Device 40 MultiConnect Cell USB Modem is not detected 40 Connection Manager is not working and a device connected to the computer is not detected 40 Connection Manager displays D...

Страница 6: ...vides information on using the developer board with the MTQ S000610 Quectel EG9x AT Commands Manual USB Installation Guides and other related manuals Multiple documents listing AT Commands USB install...

Страница 7: ...PRODUCT OVERVIEW Dragonfly TM MTQ LNA7 Device Guide 7 MTQ LNA7 B02 Mechanical Drawing...

Страница 8: ...the device to the right of the Micro USB Connector in the lower right corner LED Indicators LS Link Status OFF No power to the cellular radio Slow Blink 200 ms High 1800 ms Low Not registered searchi...

Страница 9: ...5 LED One link status Speed Data Speed LTE FDD Up to 150 Mbps downlink 50 Mbps uplink HSUPA Up to 5 7Mbps downlink 5 7Mbps uplink DC HSDPA Up to 42Mbps downlink 42Mbps uplink Interface USB Interface M...

Страница 10: ...y Compliance UL 60950 1 2nd Edition cUL 60950 1 2nd Edition Am 1 and Am 2 Telecom Approvals Verizon AT T PTCRB Radio performance may be affected by temperature extremes Device has been tested up to 85...

Страница 11: ...C 17 N C 18 N C 19 N C 20 N C 21 N C 22 N C 23 N C 24 N C 25 N C 26 N C 27 RADIO_VDD 0 1 8V 1 8V O This output is generated by the radio 28 GND GND GND Ground 29 RADIO_RTS 0 3 3V 3 3V I Request to se...

Страница 12: ...del Number DF17 2 0 40DP 0 5V 57 Electrical Characteristics Operating Conditions Parameter Minimum Volts Maximum Volts Supply Range Vcc 3 3V 5 5V 5 Absolute Maximum Rating Parameter Minimum Volts Maxi...

Страница 13: ...ed in production 2 Guaranteed by design not tested in production Input Output Current Ratings Output current draw PWR_GOOD CHG_MON 5 mA Output current draw all other output pins 25 mA Power Draw MTQ L...

Страница 14: ...e average peak current during a GSM850 transmission burst period or HSDPA LTE connection The transmission burst duration for GSM850 can vary depending on what transmission scheme is being deployed GPR...

Страница 15: ...ivers Installation Guide see Documentation in Chapter 1 for more details For driver installation instructions for Quectel radios using Linux refer to the Linux USB Driver User Guide see Documentation...

Страница 16: ...are three options for communicating with the device Install cellular radio USB drivers and plug into the micro USB connector No need for a host board Establish serial communication using MultiTech de...

Страница 17: ...s If the reset line is held low for 50ms the radio is turned off When the reset line is released the radio is turned on Low Power Options See Powering Down the Device for the lowest power consumption...

Страница 18: ...E Antenna with SMA Male Connector Model Number GY115IE002 001 MultiTech ordering information Model Quantity ANLTE4 1HRA 1 ANLTE4 2HRA 2 ANLTE4 10HRA 10 ANLTE4 50HRA 50 Antenna Specifications Category...

Страница 19: ...to determine which antenna to connect to which U FL connector on the device Connecting an Antenna through the Developer Board Connectors To connect an antenna to the device through the developer boar...

Страница 20: ...e very close together Antenna diversity provides an advantage in complex environments because if one receive antenna has a poor signal due to an interference null pattern the other antenna is likely n...

Страница 21: ...a Antenna Approvals and Safety Considerations Note the following The carriers conduct antenna diversity tests There are no EMC concerns about antenna diversity All antennas need to have a minimum flam...

Страница 22: ...ehicle with fuel Switch OFF your wireless device in hospitals and any other place where medical equipment may be in use S curit relative aux appareils radiofr quence RF cause du risque d interf rences...

Страница 23: ...to ensure that cardiac pacemakers and defibrillators are safe from cellular device EMI The FDA continues to monitor cellular devices for interactions with other medical devices If harmful interference...

Страница 24: ...ecifically approved for such use The device may cause sparks Sparks in explosive areas could cause explosion or fire and may result in property damage severe injury and or death Do not expose your dev...

Страница 25: ...ification The MultiTech model identification allows the carrier to verify the modem as one of its approved models This information is located on the modem s label below the bar code Labels This device...

Страница 26: ...ween the equipment and receiver Connect the equipment into an outlet on a circuit different from that to which the receiver is connected Consult the dealer or an experienced radio TV technician for he...

Страница 27: ...ll persons and must not transmit simultaneously with any other antenna or transmitter except as evaluated in this filing or in accordance with FCC multi transmitter product procedures The antenna s us...

Страница 28: ...t It does not imply that Industry Canada approved the equipment Notice The REN assigned to each terminal equipment provides an indication of the maximum number of terminals allowed to be connected to...

Страница 29: ...Hz RF Power W Minimum RF Power W Maximum Occupied Bandwidth kHz Emmission Designation Designation D mission 779 5 784 5 0 202 0 202 4530 W7D 779 5 784 5 0 209 0 209 9050 W7D 826 4 846 6 0 209 0 209 41...

Страница 30: ...ry Canada The equipment for which this certificate is issued shall not be manufactured imported distributed leased offered for sale or sold unless the equipment complies with the applicable technical...

Страница 31: ...on the product or on its packaging which indicates that this product must not be disposed of with other waste Instead it is the user s responsibility to dispose of their waste equipment by handing it...

Страница 32: ...tain the following banned chemicals1 Lead Pb 1000 PPM Mercury Hg 100 PPM Cadmium Cd 100 PPM Hexavalent Chromium Cr 6 1000 PPM Polybrominated Biphenyl PBB 1000 PPM Polybrominated Diphenyl Ethers PBDE 1...

Страница 33: ...propriate drivers are installed can cause the connection to fail To install Connection Manager and the device drivers 1 Go to https www multitech com support connection manager 2 Click Connection Mana...

Страница 34: ...mputer if prompted by Windows If using a USB device you can connect the device to the carrier s network with Connection Manager Refer to Connecting a Device If using a serial device you need to set up...

Страница 35: ...g another model may cause your device to work incorrectly or fail f Select your COM port then click Next g Click Finish h Go to Device Manager Modems and confirm that the device is added 6 To verify t...

Страница 36: ...ngs to a host check Enable keep alive and enter the IP address or host name to ping in the Host to ping box For example you can enter the host name google com or IP address 8 8 8 8 If the keep alive c...

Страница 37: ...ength percentage and bars The statistics on connection speeds and traffic are available only during a current connection session Note For serial modems the signal strength is available only when the d...

Страница 38: ...lowing Status of device connection Searching Connecting Connected Disconnecting or Disconnected The action button which changes according to the current device connection status Detect Connect or Disc...

Страница 39: ...ection tab The Connection tab displays the following The carrier provided connection settings The Enable keep alive check box Check this box to monitor connectivity to the Internet Check Enable keep a...

Страница 40: ...se Connection Manager is not working and a device connected to the computer is not detected Connection Manager cannot detect a connected device because the required drivers are not installed The most...

Страница 41: ...ings tab 38 Terminal tab 38 troubleshooting 40 uninstalling 37 D device connecting to carrier s network with Connection Manager 36 maintenance 24 device drivers installation for use with Connection Ma...

Страница 42: ...RF interference 22 vehicle 23 shutdown 16 SIM card installing 15 sleep mode 17 SMA to U FL 19 SMA to U FL cable 19 specifications 9 static 22 s curit interf rences RF 22 T troubleshooting Connection M...

Отзывы: