VersaTemp™ Water-to-Water Heat Pumps
Air Cooled Template
VersaTemp™ Water-to-Water Heat Pump
with Auxiliary Air-Cooled Coil
Product Data Catalog
ARA 020X, 030X, 060X Modules
Страница 1: ...1 VersaTemp Water to Water Heat Pumps 1 Air Cooled Template VersaTemp Water to Water Heat Pump with Auxiliary Air Cooled Coil Product Data Catalog ARA 020X 030X 060X Modules...
Страница 2: ...er to Water Heat Pumps Contents ARA Features Benefits 3 Model Number Nomenclature 4 5 General Information 6 7 Unit Dimensions Configurations 8 15 Electrical Piping Requirements 16 Guide Specifications...
Страница 3: ...ith refrigerant and are factory run tested prior to shipment on an AHRI certified test stand ARA modules are ETL listed according to UL Standard 1995 and CSA certified per Standard C22 2 236 Compresso...
Страница 4: ...Heat Pump 4 A Brazed SS V Other 5 A Cu tube Al fin B Cu tube Cu fin V Other 6 A None B Bronzeglow H Heresite E Electrofin S Standard V Other 7 E ECM Fans H High static L Single Fan V Other 8 R 410A P...
Страница 5: ...60 H 460 3 60 C 575 3 60 D 200 3 50 E 400 3 50 F 380 3 60 S 220 230 1 60 V Other Accessory Module ACP 2 H C 180 M B S C TankVolume Three digits 000 None Gallons Water Piping C Copper S Stainless P PVC...
Страница 6: ...4 1 Quantity 2 2 4 FanType Axial Axial Axial Fan Material Composite Composite Composite Air Flow Per Module per module 16 000 22 000 44 000 Air Cooled Coil ARA 020X ARA 030X ARA 060X Fin Material Alu...
Страница 7: ...sword levels provide three different access modes to the parameters read only for assistance edit for servicing and total access for the manufacturer Additional features include WiFi interface for tab...
Страница 8: ...s Typical Unit Dimensions ARA 020X Single Module Dimensions CLEARANCES No obstructions above fans Horizontal clearances as shown on drawing Multistack does not recom mend pit installations Consult Mul...
Страница 9: ...ps Typical Unit Dimensions ARA 030X Single Module Dimensions CLEARANCES No obstructions above fans Horizontal clearances as shown on drawing Multistack does not recommend pit installations Consult Mul...
Страница 10: ...umps Typical Unit Dimensions ARA 030X Two Modules Dimensions CLEARANCES No obstructions above fans Horizontal clearances as shown on drawing Multistack does not recommend pit installations Consult Mul...
Страница 11: ...Dimensions Typical Unit Dimensions ARA 020X with ASP 020X Units CLEARANCES No obstructions above fans Horizontal clearances as shown on drawing Multistack does not recom mend pit installations Consult...
Страница 12: ...mps Dimensions CLEARANCES No obstructions above fans Horizontal clearances as shown on drawing Multistack does not recommend pit installations Consult Multistack Representative for options Typical Uni...
Страница 13: ...umps Typical Unit Dimensions ARA 060X Two Modules Dimensions CLEARANCES No obstructions above fans Horizontal clearances as shown on drawing Multistack does not recommend pit installations Consult Mul...
Страница 14: ...mps Typical Unit Dimensions ARA 060X Four Modules Dimensions CLEARANCES No obstructions above fans Horizontal clearances as shown on drawing Multistack does not recommend pit installations Consult Mul...
Страница 15: ...ps Dimensions Typical Unit Dimensions ARA 060X Multiwing Fans CLEARANCES No obstructions above fans Horizontal clearances as shown on drawing Multistack does not recommend pit installations Consult Mu...
Страница 16: ...the other compressors in the system The total system Minimum Circuit Ampacity MCA shall not exceed 760A Wire sizing is based ontheNationalElectricCode NEC ratingfor75 Ccopperwire threewiresperconduit...
Страница 17: ...structions for transporting rigging and assembly of modular chiller 1 06 WARRANTY A Manufacturer s equipment warranty shall be for a period of one 1 year from date of equipment start up or 18 months f...
Страница 18: ...essure reductions at 30 feet as compared to standard fan option ranges from 3 6 dBA H Central Control System 1 Scheduling of the various compressors shall be performed by a microprocessor based contro...
Страница 19: ...suction gas temperature 6 Low leaving evaporator water temperature B Failure of chiller to start or chiller shutdown due to any of the above safety cutouts shall be annunciated by display of the appr...
Страница 20: ...a professional water treatment specialist who is familiar with the operating conditions and materials of construction specified for the chiller s heat exchangers headers and associated piping Cycles...