background image

UTR-1244

AUXILIARY SUPPLY:

UNIVERSAL TIMER

Supply voltage

Power consumption
(VA RATING)

Approx 4 VA @ 230V AC MAX

ENVIRONMENT CONDITION:

Relative Humidity

Protection Level
(AS Per Request)

 Operating Temp.

0°C to 55°C

UP to 95% RH 
(non-condensing)

IP-65 (Front side) As per IS/IEC
60529 : 2001

100 to 270V AC, 50-60Hz

MECHANICAL INSTALLATION GUIDELINES

1. Prepare the panel cutout with proper dimensions as shown 
    above.

   

2. Fit the unit into the panel with the help of clamp given.

   

3. The equipment in its installed state must not come in close 
    proximity to any heating source, caustic vapors, oils steam, 
    or other unwanted process byproducts.
   

4. Use the specified size of crimp terminal (M3.5 screws) to 
    wire the terminal block. Tightening the screws on the 
    terminal block using the tightening torque of the range of 
    1.2 N.m.

   

5. Do not connect anything to unused terminals. 
   

INSTALLATION GUIDELINES

1. This equipment, being built-in-type, normally becomes a 
    part of main control panel and in such case the terminals
    do not remain accessible to the end user after installation 
    and internal wiring.                                                                                                                                                                                                                                                                                                                                                                                                                      

2. Do not allow pieces of metal, wire clippings, or fine metallic 
    fillings from installation to enter the product or else it may 
    lead to a safety hazard that may in turn endanger life or 
    cause electrical shock to the operator.      

3. Circuit  breaker or mains switch must be installed between 
    power source and supply terminal to facilitate power ‘ON’ or 
   ‘OFF’ function. However this mains switch or circuit breaker 
    must be installed at convenient place normally accessible to 
    the operator.     

4. Use and store the instrument within the specified ambient 
    temperature and humidity ranges as mentioned in this 
    manual.     

Page -1

MAINTENANCE

1. The equipment should be cleaned regularly to avoid 
    blockage of ventilating parts.         

2. Clean the equipment with a clean soft cloth. Do not use 
    isopropyl alcohol or any other cleaning agent.

3. Fusible resistor must not be replaced by operator. 

Read complete instructions prior to installation 
and operation of the unit. 

WARNING :

 Risk of electric shock.

SAFETY PRECAUTION

!

       All safety related codifications, symbols and instructions 
that appear in this operating manual or on the equipment 
must be strictly followed to ensure the safety of the operating 
personnel as well as the instrument. 

      If all the equipment is not handled in a manner specified 
by the manufacturer, it might impair the protection provided 
by the equipment.

WARNING GUIDELINES

WARNING : Risk of electric shock.

 1. To prevent the risk of electric shock, power supply to the 
     equipment must be kept OFF while doing the wiring 
     arrangement. Do not touch the terminals while power is 
     being supplied.  

 2. To reduce electro magnetic interference, use wire with 
     adequate rating and twists of the same of equal size shall 
     be made with shortest connection.            

 3. Cable used for connection to power source, must have a 
     cross section of 1mm or greater. These wires should have 
     insulations capacity made of at least 1.5kV.      

  4. A better anti-noise effect can be expected by using 
      standard power supply cable for the instrument.         

Input (Start Pulse)

Time Range

Display

Operating Mode

Size 

Keys

Counting Direction

Panel Cutout

Upper: 4 digit, 7 segment, 0.70” Red

Forward - Reverse Timer 

Lower: 4 digit, 7 segment, 0.50” Green

96 (H) x 96 (W) x 52 (D) mm

SET/ENT, SHIFT, INC, RESET

92 (H) x 92 (W) mm

TECHNICAL SPECIFICATION

GENERAL SPECIFICATION:

DISPLAY AND KEYS:

DIMENSION:

MECHANICAL INSTALLATION

TERMINAL CONNECTION

1 - Relay 1 control output 

2 - Relay 2 control Output 

STATUS LED DESCRIPTION

KEY OPERATION

To enter in parameter setting 
mode

To reset the timer

PRESS KEY

FUNCTION

OPERATOR MODE

PARAMETER SETTING MODE

Edited parameter value to be set, 
And move to the next parameter

It will select the digit to modify, 
When value is edited

It will change the Value of 
selected digit

Page -2

NPN/PNP Proximity

Sec (9.999/999.9/9999)

Micro Switch

Min (99.59/999.9/9999)

Limit Switch

Hour (99.59/999.9/9999)

Cyclic Timer 
Sequential Timer  
Combination Timer  

UP/ DOWN

Reset Option

Front Panel Reset

Terminal Reset

96

92

92

96

Outline Dimension (mm)

Panel Cutout 
Dimension (mm)

Press         Key along

  with power on device 

RESET

SEQUENTIAL TIMER

OPERATING MODE FUNCTION

Start pulse

Start pulse

COMBINATION TIMER

dL-1

d1c1

dL-2

Of-1

d1c2

Of-2

on-1

r1c1

on-2

5

5

5

5

10

10

10

10

15

15

15

15

20

20

20

20

25

25

25

25

30

30

30

30

35

35

35

35

40

40

40

40

45

45

45

45

50

50

50

50

55

55

55

55

60

60

60

60

65 70

R

ela

y-1

R

ela

y-1

R

ela

y-2

R

ela

y-2

Relay-1 setting

Relay-1 setting

dL-1(Delay time )= 5 sec

d1c1(Delay Time Of Relay 1 & cycle 1)= 5 sec

dL-2(Delay time)= 10 sec

                    d2c1(Delay Time Of Relay 2 & cycle 1)= 5 sec

of-1(Off time)= 5 sec

d1c2(Delay Time Of Relay 1 & cycle 2)= 5 sec

r1c2(Relay on time Of Relay 

2) = 10 sec

1 & cycle-

Cyc1(Relay  combination) = 2 

Cyc2(Relay  combination) = 2 

of-2(Off time)= 10 sec

                             d2c2(Delay Time Of Relay 2 & cycle 2)= 10 sec

                                 r2c2(Relay on time Of Relay 

2) = 10 sec

2& cycle-

on-1(On time )= 10 sec

r1c1(Relay on time Of Relay 1 

 )=10 sec

& cycle-1

on-2(On time)= 20 sec

                         r2c1(Relay on time Of Relay 

 )= 10 sec    

2& cycle-1

Relay-2 setting

Relay-2 setting

cyc(Total no. of repeat cycle of Relay 1 & Relay 2)= 1

nocl(

)=2 

Total no. of Relay-1 & Relay-2 Combination

d1c1

d1c2

r1c2

r1c1

r1c2

Time(Sec)

Time(Sec)

r2c1

d2c1

d2c2

r2c2

r2c1

d2c1

r2c2

d2c2

TIME

SET TIME

9939

9939

1

2

 FORWORD REVERSE TIMER 

Start pulse

cyclic on 

cyclic off 

CYCLIC TIMER

on time (ontm)= 5 sec

off time (oftm)= 10 sec

Reverse time

sttm 

sttm 

sttm

sttm

sttm

sttm

sttm

sttm

5

0

5

0

10

10

15

15

20

20

25

25

25

25

25

20

20

20

20

15

15

15

15

10

10

10

10

5

5

5

5

25

30

30

30

30

30

30

35

35

40

40

45

45

50

50

55

55

60

60

R

ela

y-1

R

ela

y-1

R

ela

y-2

R

ela

y-1

R

ela

y-2

R

ela

y-2

Forword Time (Frtm) = 10 SeC

Stop Time (Sttm) = 5 Sec 

Total Time (totl) = 1 min

Reverse Time (rvtm) = 10 Sec

on time

off time

off time

on time

off time

off time

on time

on time

Time(Sec)

Time(Sec)

Time(Sec)

Time(Sec)

Forward time

Time
   (sec)

Time
   (sec)

Forward time

Reverse time

Time(Sec)

Time(Sec)

ontm

ontm

ontm

ontm

oftm

oftm

oftm

oftm

This symbol in all graph
will represent Relay is On 

-

INPUT SPECIFICATION:

OUTPUT SPECIFICATION:

Relay

Relay Type

Rating

2 nos.

1 C/O (NO-C-NC)

5A, 230V AC

Relay Output

UTR 1244

99

.

39

99

.

39

SET
ENT

RESET

TIME

SET TIME

.

PROXY COLERS CODE

+12V

OUTPUT

GND

Brown

Black

Blue

Red

Green

Black

52

3

oftm

12

13

14

11

16

17

18

19

20

15

RESET

GND

PNP

I/P

+12V

NPN

I/P

1

7

8

9

10

2

3

4

5

6

NC

C

NO

Relay-1

L

N

~

 

!

NC

C

NO

Relay-2

www.multispanindia.com

100
270V AC

Made in India

Отзывы: