background image

UTR 2044

R

 



TIME

SET TIME

SET
ENT

RESET

www.multispanindia.com

Page - 1

UTR-1044,2044,444

Technical Specification  

Connection Diagram  

OPERATING MANUAL 

PID TEMPERATURE CONTROLLER                           

UTC-121P,221P & 421P

OPERATING MANUAL 
UNIVERSAL TIMER                           
UTR-1044,2044,444

Output 

 Power Supply

 Protection Level

    Operating

    Relative

 (As per request)

 Temperature

   Humidity

          1 relay, 2 C/O contact, 230V AC, 5A

100 to 250V AC, 50 / 60 Hz, Approx 4VA 

IP-65(Front side) AS per IS/IEC 60529:2001

0°C To 55°C

Up to 95% RH Non Condensing

Model

Display

Size(HXWXD)
Panel Cutout

Input

UTR 1044

96 X 96 X 50 mm

68 X 68 mm

92 X 92 mm

44 X 44 mm

72 X 72 X 85 mm

48 X 48 X 70 mm

UPPER:- 4 Digit 7 seg 0.70”,red LED Display

UPPER:- 4 Digit 7 seg 0.70”,red LED Display

LOWER:- 4 Digit 7 seg 0.4”,green LED Display

LOWER:- 4 Digit 7 seg 0.28”,green LED Display

UTR 2044

UTR 444

NPN/PNP Proximity & Micro Switch

NPN Proximity & Micro Switch

Notes:

1).  For safely purpose, key function are designed in such a way that operator will not go into
        detailed parameter setting (Previously Set) function. In this situation, in LOCK parameter, 
        YES has to be selected. If previously set parameters are to be changed, then any operator 
        has to select NO.
2).   POWER ON () : Timer starts counting as soon as it gets power supply.
3).   By default Cycle ON Mode is provided. Please refer programming guide to change to Cycle OFF
       Delay ON/ Delay OFF Mode.

!

100  
250V AC
    

~

 

50/60 HZ
4VA

1

2

3

4

5

L

N

7

6

8

9

10

11

12

NC

RELAY

RESET

NC

C

NO

NO

M/S

PROXI NPN

I/P

+12V

GND

~

 

50/60 HZ
4VA

100
250V AC

N0

N0

+12V

I/P1

I/P2

GND

M/S

NC

NC

C

C

L

N

1

2

3

4

5

6

7

8

9

10

11

12

13

14

RESET

RELAY

RELAY

PNP PROXI:- 

Short Pins 5 & 6

MICRO SWITCH:- 

Short Pins 5 & 6

                        Proxi Connection 

to 3, 4 & 5

                        M/S Connection 

3 & 4

NPN PROXI:-  

Short Pins 3 & 4

                         Proxi Connection 

to 4, 5 & 6

1

7

8

9

12

13

14

10

11

16

17

18

19

20

15

2

3

4

5

6

~

 

50/60 HZ
4VA

100
250V AC

M/S

RESET

GND

I/P2

+12V

I/P1

L

N

NPN PROXI:- Short Pins 16 & 15

MICRO SWITCH:- Short Pins 14 & 13

                        Proxi Connection to 15,14 & 13

                        M/S Connection 16 & 15

PNP PROXI:-  Short Pins 14 & 13

                         Proxi Connection to 16,15 & 14

NC

NC

C

C

NO

NO

Relay

Relay

UTR 1044

TIME

SET TIME

 



SET
ENT

RESET

RESET

SET
ENT

UTR 444

SET TIME

    TIME

R

1

R

2





Отзывы: