FACTORY SETTING

FACTORY SETTING

PARAMETER

IC

CT

OFFSET

PC

DC

MR

HYSTERESIS-2
HYSTERESIS-3

HYSTERESIS

VALUES

0.225

6 sec

05.00

25

0

°C

0

°C

    1

°C

    1

°C

    1

°C

SR.

2

4

6

1

3

5

7
8
9

Process Value

Set Value

Factory Setting

Press       +       key for 3 sec 

Connection Diagram For Relay:

Connection Diagram For S.S.R:

N

L

C

CC

H

B

C

NO

 FOR AL

NO

NO

NC

N

L

H

AL

B

-

-

-

+

+

+

 SSR

 SSR

 SSR

Off-set correction

-20.0 C to +20.0 C

°

°

-20 C to +20 C 

°

°

CT

4 sec to 99 sec

IC

0.000 to 9.999

Hysteresis

0.1 C to 50.0 C 

°

°

1°C to 50°C

MR

-9.0 to +9.0 

-9 to +9 

DC

0 to 9999

PC

Sr.

1
2
3
4
5

6
7

00.00 to 99.99

Parameter

Range for PT.1 sensor

Range for J, K, PT100

Содержание UTC-423

Страница 1: ...0 0 C º PID ON OFF selectable Output 1 Output 2 Output 3 Power Supply 100 to 250V AC 50 60 Hz smps Model Display Size Panel Cutout Input Temperature Range Control Action 44 X 44 48 X 48 X 95 UPPER 4 Digit 7 seg 39 red LED Display LOWER 4 Digit 7 seg 28 green LED Display UTC 423 J K PT 100 selectable 1st Output Relay or S S R 2nd Output Relay or S S R 3rd Output Relay or S S R OPERATING MANUAL UNIV...

Страница 2: ...ec to enter Password parameter PROCESS VALUE Input J K Pt100 Pt 1 Control Action Set2 Mode Set3 Mode Time 3 Mode Time 3 Unit Individual Relative H AL L AL I AL O AL OFF ALMT OFF SEC MIN HOUR PID ON OFF Password Message Press ENT key to Save Exit K TO ENTER BASIC CONFIGURATION SETTING ENTER 73 Set Point Low Limit Set Point High Limit OFF SET Press SET key ...

Страница 3: ...ameters Proportional Constant Integral Constant Derivative Constant Cycle Time Manual Reset Cool HYS CONTROL PARAMETER TO ENTER CONTROL PARAMETER SETTING ENTER 37 Press ENT key to Save Exit IF PID SELECTED IF ON OFF SELECTED ON OFF Parameters Hysteresis 1 ...

Страница 4: ...RESIS 3 HYSTERESIS VALUES 0 225 6 sec 05 00 25 0 C 0 C 1 C 1 C 1 C SR 2 4 6 1 3 5 7 8 9 Process Value Set Value Factory Setting Press key for 3 sec Connection Diagram For Relay Connection Diagram For S S R N L C C C H B C NO FOR AL NO NO NC N L H AL B SSR SSR SSR Off set correction 20 0 C to 20 0 C 20 C to 20 C CT 4 sec to 99 sec IC 0 000 to 9 999 Hysteresis 0 1 C to 50 0 C 1 C to 50 C MR 9 0 to 9...

Отзывы: