![MULTISPAN UTC-3203 Скачать руководство пользователя страница 2](http://html1.mh-extra.com/html/multispan/utc-3203/utc-3203_operating-manual_1855471002.webp)
Off-set correction
1 to 999 Sec
1 to 999 Sec
-20.0°C to +20.0°C
-20°C to +20°C
Delay Time 1 To 3
CT
4 sec to 99 sec
4 sec to 99 sec
IT
000 to 9999
000 to 9999
Hysteresis 1 To 3
0.1°C to 50.0°C
1°C to 50°C
MR
PB
-9.0 to +9.0
2.0 to 20.0
-9 to +9
2 to 20
DT
000 to 9999
000 to 9999
PB
Sr.
1
2
3
4
5
6
7
8
9
000 to 999.9
000 to 999.9
Parameter
Range for PT.1 sensor
Range for J, K, PT100
Factory Setting
FACTORY SETTING
PARAMETER
IT
CT ( For PID)
PB
OFFSET
TIME-1
TIME-2
PB
DT
MR
HYSTERESIS-1
HYSTERESIS-2
HYSTERESIS-3
VALUES
300
15 SEC.
20.0
75
0°C
5°C
08
0°C
3°C
3°C
3°C
6 SEC
6 SEC
SR.
2
4
CT
6
1
3
5
7
8
9
10
11
12
13
ENT
ENT
yes : press key to apply factory set
values as shown in table.
nO : press key to escape
from factory setting.
Press + key
for 3 sec
IF T1MD=OFF
IF T2MD=OFF
IF 3MD=OFF
IF R1MD=OFF
IF R2MD=OFF
IF R2MD=OFF
www.multispanindia.com
Page - 3
Set Value
Set Point-1
Set Point-2
Set Point-3
Password Message
Press key for 3 sec to
enter Password
SET
Process Value
Input ( J / K / Pt.1 / Pt100 )
Control Action (PID/ON-OFF/TP)
Password Message
P T
P T
.
1
T P
O N O F
K
SET
SET
SET
SET
Press k
e
y
ENT
Set Point Low Limit
Set Point High Limit
HEAT, COOL, H-AL, AB-L
L-AL, I-AL, O-AL, OFF, AB-O
HEAT, COOL, H-AL, AB-L, AB-O
L-AL, O-AL, I-AL, E-AL, OFF
HEAT, COOL, H-AL, AB-L, AB-O
L-AL, O-AL, I-AL, E-AL, OFF
OFF-SET
TO ENTER BASIC
CONFIGURATION
SETTING, ENTER “73”
www.multispanindia.com
Page - 4
Password Message
IF PID SELECTED
IF ON-OFF SELECTED
IF TP SELECTED
SET
TO ENTER CONTROL
PARAMETER
SETTING, ENTER “37”
6) Orange color LED glows during auto tuning mode.
1) Press key to go parameter setting.
SET
3) Press key to save change in setting
ENT
4)
Press key for 6 sec to start/stop PID AUTO TUNING
5) Press + key for 3 sec to go to factory setting mode.
2) Press or key to change value or to select option.
Basic Configuration
Set Point Setting
Control Parameter
Key Operation
UTC-3203
UTC-3203
34
100
set1
100
set2
105
set3
110
pass
50
pass
73
PID
ONOF
TP
PARA
PARA
PARA
pass
37
1234
1 3
2 4
fCST
e
Y s
fCST
O
n
INPT
j
CTRL
PID
Pb
20
.
0
HYS1
3
PB
4
TIM1
6
CT
12
HYS2
3
HYS3
3
MR
0
HYS2
3
HYS3
3
TIM2
6
TIM3
6
TIM1
6
TIM2
6
TIM3
6
OFST
0
It
300
SLL
0
DT
75
TIM1
6
SHL
R1MD
tIUT
t2md
t3md
tIMD
r2md
r3md
t2ut
t3ut
CT
hys2
hys3
MR
TIM2
TIM3
600
HEAT
HOUR
almt
almt
SOhT
E-AL
E-AL
E-AL
MIN
15
3
3
0
6
6
Press key to
Save & Exit
ENT
Press key to Save & Exit
ENT
Press key to Save & Exit
ENT
Press key
SET
Press k
e
y
SET
Press k
e
y
SET
Press k
e
y
SET
Manual Reset
Proportional
Band
Integral
Time
Derivative
Time
Cycle Time
PID
Parameters
ON-OFF
Parameters
TP
Parameters
Hysteresis
IF T1MD = SOAK
or SKPS or SKRG
IF T2MD = OFF
IF T2MD = OFF
IF R2MD = OFF
IF R2MD = OFF
or E-AL
or E-AL
IF R1MD = OFF
IF T2MD = OFF
IF T3MD = OFF
or E-AL
IF R2MD = OFF
or E-AL
IF R3MD = OFF
IF T1MD = OFF
IF T1MD = SOAK
or SKPS or SKRG
or E-AL
or E-AL
IF R2MD = OFF
IF R3MD = OFF
IF T3MD = OFF
IF T2MD = OFF
ONDL,SOKT,SKPS,SKRG,ALMT,OFF
SEC/MIN/HOUR
SEC/MIN/HOUR
SEC/MIN/HOUR
SOKT,SKRG,SKPS,ALMT,ONDL,OFF
SOKT,SKRG,SKPS,ALMT,ONDL,OFF
PID AUTO-TUNING
Press key for 6 sec to start/stop
PID auto-tunning
PV
SV
1234
1234
IF RELATIVE (-50°C To +50
°C)
IF RELATIVE (-50°C To +50
°C)
s2md
s3md
end
indu
indu
NO
Press key
SET
IF R1/R2 MD=OFF
Save / No
INDIVIDUAL/RELATIVE
INDIVIDUAL/RELATIVE
Press key to Save & Exit
ENT
Press key to input setting
SET