MULTISPAN UTC-3203 Скачать руководство пользователя страница 2

Off-set correction

1  to 999 Sec

1  to 999 Sec

-20.0°C to +20.0°C

-20°C to +20°C 

    Delay Time 1 To 3

CT

4 sec to 99 sec

4 sec to 99 sec

IT

000 to 9999

000 to 9999

Hysteresis 1 To 3

0.1°C to 50.0°C 

1°C to 50°C

MR

PB

-9.0 to +9.0 

2.0 to 20.0 

-9 to +9 

2 to 20 

DT

000 to 9999

000 to 9999

PB

Sr.

1
2
3
4
5
6
7
8
9

000 to 999.9

000 to 999.9

Parameter

Range for PT.1 sensor

Range for J, K, PT100

Factory Setting 

FACTORY SETTING

PARAMETER

IT

CT ( For PID)

PB 

OFFSET

TIME-1
TIME-2

PB

DT

MR

HYSTERESIS-1
HYSTERESIS-2
HYSTERESIS-3

VALUES

300

15 SEC.

20.0

75

0°C

5°C

08

0°C

    3°C
    3°C

    3°C

    6 SEC
    6 SEC

SR.

2

4

CT

6

1

3

5

7
8
9

10
11
12
13

ENT

ENT

yes : press      key to apply factory set 
         values as shown in table.

 nO : press      key to escape 
         from factory setting.

Press      +      key
 for 3 sec 

IF T1MD=OFF

IF T2MD=OFF

IF 3MD=OFF

IF R1MD=OFF

IF R2MD=OFF

IF R2MD=OFF

www.multispanindia.com

Page - 3

Set Value

Set Point-1

Set Point-2

Set Point-3

Password Message

Press       key for 3 sec to 
                enter Password  

SET

Process Value

Input ( J / K / Pt.1 / Pt100 )

Control Action (PID/ON-OFF/TP)

Password Message

P T

P T

1

T P

O N O F

K

SET

SET

SET

SET

Press      k

e

ENT

Set Point Low Limit

Set Point High Limit

HEAT, COOL, H-AL, AB-L 
L-AL, I-AL, O-AL, OFF, AB-O

HEAT, COOL, H-AL, AB-L, AB-O 
L-AL, O-AL, I-AL, E-AL, OFF

HEAT, COOL, H-AL, AB-L, AB-O 
L-AL, O-AL, I-AL, E-AL, OFF

OFF-SET

    TO ENTER BASIC 
    CONFIGURATION
SETTING, ENTER “73”

www.multispanindia.com

Page - 4

Password Message

IF PID SELECTED

IF ON-OFF SELECTED

IF TP SELECTED

SET

       TO ENTER CONTROL 
            PARAMETER  
       SETTING, ENTER “37”

6)  Orange color LED glows during auto tuning mode.

1)  Press       key to go parameter setting.

SET

3)  Press      key to save change in setting 

ENT

4)  

Press      key for 6 sec to start/stop PID AUTO TUNING 

5)  Press       +       key for 3 sec to go to factory setting mode.  

  2)  Press      or       key to change value or to select option.

Basic Configuration 

Set Point Setting 

Control Parameter 

Key Operation

UTC-3203

UTC-3203

34

100

set1

100

set2

105

set3

110

pass

50

pass

73

PID

ONOF

TP

PARA

PARA

PARA

pass

37

1234

1 3

2 4

fCST

e

Y s

fCST

O

n

INPT

j

CTRL

PID

 Pb

20

.

0

 HYS1

   3

 PB

   4

 TIM1

   6

 CT

   12

 HYS2

   3

 HYS3

   3

 MR

     0

 HYS2

     3

 HYS3

     3

 TIM2

   6

 TIM3

   6

 TIM1

   6

 TIM2

   6

 TIM3

   6

OFST

0

It

300

 SLL

0

 DT

75

 TIM1

 6

 SHL

 R1MD

 tIUT

 t2md

 t3md

 tIMD

 r2md

 r3md

 t2ut

 t3ut

 CT

 hys2

 hys3

 MR

 TIM2

 TIM3

600

HEAT

HOUR

almt

almt

SOhT

E-AL

E-AL

E-AL

MIN

 15

  3

  3

  0

   6

   6

Press     key to 
Save & Exit

ENT

Press    key to Save & Exit

ENT

Press     key to Save & Exit

ENT

Press      key 

SET

Press      k

e

SET

Press      k

e

SET

Press      k

e

SET

Manual Reset

Proportional 

Band

Integral

Time

Derivative

Time

Cycle Time

PID

Parameters

ON-OFF

 Parameters

        TP

 Parameters

Hysteresis 

IF T1MD = SOAK

or SKPS or SKRG

IF T2MD = OFF

IF T2MD = OFF

IF R2MD = OFF

IF R2MD = OFF

      or E-AL

      or E-AL

IF R1MD = OFF

IF T2MD = OFF

IF T3MD = OFF

      or E-AL

IF R2MD = OFF

      or E-AL

IF R3MD = OFF

IF T1MD = OFF

IF T1MD = SOAK

or SKPS or SKRG

      or E-AL

      or E-AL

IF R2MD = OFF

IF R3MD = OFF

IF T3MD = OFF

IF T2MD = OFF

ONDL,SOKT,SKPS,SKRG,ALMT,OFF

SEC/MIN/HOUR

SEC/MIN/HOUR

SEC/MIN/HOUR

SOKT,SKRG,SKPS,ALMT,ONDL,OFF

SOKT,SKRG,SKPS,ALMT,ONDL,OFF

PID AUTO-TUNING

Press       key for 6 sec to start/stop

PID auto-tunning 

PV

SV

1234

1234

IF RELATIVE (-50°C To +50

°C)

IF RELATIVE (-50°C To +50

°C)

 s2md

 s3md

 end

indu

indu

NO

Press      key 

SET

IF R1/R2 MD=OFF

Save / No

INDIVIDUAL/RELATIVE

INDIVIDUAL/RELATIVE

Press     key to Save & Exit

ENT

Press     key to input setting

SET

Отзывы: