www.multispanindia.com
Page - 3
P A s s
Password
Message
IF PID SELECTED
IF ON-OFF SELECTED
p B
0 2 0 0
.
I T
0 1 2 5
C T
0 0 3 0
M R
D T
0 0 1 5
0 0 0 0
Proportional
Band
Integral
time
Derivative
time
Cycle Time
Manual Reset
0 0 3 7
TO ENTER CONTROL
PARAMETER
SETTING, ENTER “37”
SET
SET
Press key
to Save & Exit
Press key
to Save & Exit
Hysteresis
H Y S t
0 0 0 3
TC-29P
PID AUTO-TUNNING
Press key for 6 sec to start/stop
PID auto-tunning
PV
1 2 3 4
Off-set correction
-10°C to +10°C
IT
CT
0 To 9999
4 Sec To 99 Sec
Hysteresis
1°C to 10°C
DT
MR
0 To 9999
-9°C to 9°C
PB
Sr.
1
2
3
4
5
6
7
0 To 999.9
Parameter
Range for J type
Factory Setting
FACTORY SETTING
PARAMETER
IT
CT ( For PID)
OFFSET
PB
DT
HYSTERESIS-1
MR
VALUES
125
15 SEC.
20.0
30
3°C
0
0
SR.
2
4
1
3
5
6
7
Y E S
SET
SET
yes : press key to apply factory set
values as shown in table.
nO : press key to escape
from factory setting.
n O
Press + key
for 3 sec
1 2 3 4
f C S T
Control Parameter