Section 1
APPLICABLE TO R290 UNITS ONLY
WARNING:
DO NOT DISPOSE OF THE UNIT WITHOUT FIRST REMOVING ALL R290
REFRIGERANT. THIS PROCESS CAN ONLY BE PERFORMED BY AN ENGINEER
QUALIFIED TO HANDLE HYDROCARBON REFRIGERANTS.
WARNING:
ALL UNITS ARE FITTED WITH A STANDARD EURO PLUG TO IEC83:1985 OR A UK
PLUG. BEFORE COMMENCING ANY CLEANING ISOLATE THE UNIT BY:
1. SWITCH OFF THE SOCKET THAT THE PLUG IS INSTALLED INTO.
2. REMOVE THE PLUG FROM THE SOCKET.
WARNING:
ALL INSTALLATIONS MUST BE CHECKED THAT THEY MEET LOCAL
ELECTRICAL REGULATIONS AND NATIONAL CODES BEFORE THE
APPLIANCE IS TURNED ON.
WARNING:
IF THE MAINS LEAD FITTED TO THIS EQUIPMENT IS IN ANY WAY DAMAGED IT
MUST BE REPLACED. THIS WORK SHOULD ONLY BE PERFORMED BY WELBILT
(HALESOWEN) LIMITED, OUR SERVICE AGENT OR A QUALIFIED ELECTRICAL
ENGINEER.. THE MAINS LEAD CONECTION IS A ‘Y’ TYPE.
WARNING:
THIS EQUIPMENT MUST BE EARTHED.
WARNING:
SOME VERSIONS OF THE ICECORE 10 COLD CARBONATED UNIT ARE FITTED
WITH AN INTERNAL 3 PIN MAINS SOCKET. THIS IS ONLY TO BE USED AS A
SOCKET FOR THE DOUBLE INSULATED TELEMETRY POWER SUPPLY MODULE
THAT SUPPLIES POWER TO THE TELEMETRY KIT THAT MAY BE FITTED TO
THIS EQUIPMENT IS CHARGED WITH R290 REFRIGERANT (PROPANE).
ONLY QUALIFIED SERVICE ENGINEERS HOLDING A VALID HANDLING CERTIFICATE FOR
CARE 40 (PROPANE) CAN WORK ON THE REFRIGERATION SYSTEM OF THIS EQUIPMENT.
PLEASE READ THE INFORMATION BELOW BEFORE ANY WORK IS CARRIED OUT.
Refrigeration R290 (Care 40, Propane)
Note: Only engineers who have been trained in the safe handling and
use of hydrocarbon refrigerants should work on this system.
• Work on this system in a wall ventilated area or outside.
• Use a local leak detector to indicate if there is hydrocarbon
in the air around the system (place it at a low level as HCs are
heavier than air)
ȏ(QVXUHWKHUHDUHQRVRXUFHVRILJQLWLRQȵDPHVRUVSDUNLQJ
electrical components) within 3m (10 feet) of your work area.
• If replacing components use like for like replacements.
• Take great care when brazing to ensure all HC has been
removed from the system.
Use refrigerant grade propane (R290 or Care 40)
Warning