Guarantee 

The unit is guaranteed in accordance with the terms and conditions against material and 
manufacturing defects. 
During the warranty period (1 year), the device may only be repaired by the manufacturer, who 
reserves, service the unit of to replace all or part of. 
The cost of returning the product to the manufacturer shall be borne by the buyer. 

The warranty is closed out in the following cases: 
1. improper use of the equipment or use with incompatible 
Accessories; 
2. in changes to the device without permission from the Her-steller; 
3. whenever acting on the device by a non-authorized person by the manufacturer; 
4. When adapting the device to applications for which the device is not provided 
is seen and that are not listed in the user manual; 
5. in damage from impact, fall or prolonged immersion. 

Unpacking – Packing 

Before  shipping  the  equipment  has  been  tested  mechanically  and electronically  in  detail  and  all 
precautions have been taken in order to receive the instrument in a-perfect condition. Please check 
the  device  during  unpacking  for  full-ness  and  transport  damage.  Notifications 
s When transport damage immediately to the respective delivery service. 

If you want to send the device, to use preferably the original packaging and place it in an email in 
which you describe the reasons for the return as clearly as possible. 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Содержание VT 35

Страница 1: ...Instruction manual Tester for outlets and GFCI from 10mA to 30mA ...

Страница 2: ... device is only suitable for systems up to 230 V of Appendix II category Asset classes in accordance with IEC 664 1 CAT I Circuits that provide protection so that the surges are limited to a low level Example protected electronic equipment CAT II Circuits for domestic appliances or similar devices where over voltages medium height may occur Example flat portable power tools etc CAT III Circuits fo...

Страница 3: ...ice by a non authorized person by the manufacturer 4 When adapting the device to applications for which the device is not provided is seen and that are not listed in the user manual 5 in damage from impact fall or prolonged immersion Unpacking Packing Before shipping the equipment has been tested mechanically and electronically in detail and all precautions have been taken in order to receive the ...

Страница 4: ...Description Connector for 2 pin socket earth test button Selector switch for tripping current ...

Страница 5: ...ault current circuit breaker 30 mA 1 Check explained and fix the socket in the previous section optionally displayed error 2 Set the selector switch for GFCI tripping current to 10mA Smallest fault current value 3 Check the response of the RCCB by briefly pressing the test button If the GFCI is not triggered 1 Increase the fault current by turning the dial to a position turn right to the next high...

Отзывы: