Multiform PS020A Скачать руководство пользователя страница 4

User Manual: PS020A

 

DMX-controlled 3-CHANNEL Power Supply     

 

 

 

 

V1.00 (06-2007) © Multiform, Leigh-on-Sea, UK                                                                                               

4

 

 

Protection from fire: 

1.  Take care of not placing the unit near sources of heat (e.g. 

powerful amplifiers, fog machines). 

2.  Take always care of sufficient air convection in the unit’s 

environment to avoid overheating, especially when mounting in a 
closed environment. Make sure air convection slots are not 
blocked. Do not operate this unit in environmental temperatures 
exceeding 40 degrees Celsius.  

3.  Check the total maximum power of your AC wall outlet if you 

connect several units to one wall outlet and avoid any overloading. 

 

 

Protection from injury and damage: 

1.  Never use any accessories or modifications not authorized by the 

manufacturer of this unit. 

2.  Choose a location for operation where the unit is protected from 

vibration and where a fixed mounting position is provided. In case 
of overhead-mounting, follow appropriate rigging rules and your 
country’s regulations for rigging safety. See appendixes if any.  

3.  Before plugging the AC cord in the wall outlet, check whether the 

AC mains voltage and frequency is the same as this product is 
specified for. Whenever your AC plug should not match the wall 
outlet, contact you dealer immediately. 

4.  If fluids have spilled into the unit or small parts have intruded the 

unit, immediately switch off the unit and hand it over to the 
authorized service for a security check. 

5.  Disconnect the unit from AC supply by pulling the AC plug out of 

the wall outlet or the unit’s AC socket during a thunder-storm in 
order to avoid any damage on the unit due to AC voltage peaks. 

6.  In cause of not correct function of this unit or damaged AC cord or 

other damaged parts, pull immediately the AC plug out of the wall 
outlet and hand the unit over to the authorized service for a 
security check.  

7.  To meet all aspects of functionality and security during mainte-

nance work to be preformed on this unit, all parts should be 
replaced by genuine spare parts. Consequently, take care of your 
dealer or maintenance company to be authorized by the 
manufacturer. 

 

 

Health advice

 

 
This unit produces and absorbs electromagnetic radiation. The strength of radiation and 
the sensitivity for disturbing interference matches the CE and FCC requirements. A 
corresponding sign is printed on the backside of the unit. Any change or modification 
may affect the behavior of the unit concerning electromagnetic radiation, with the CE 
requirements eventually not to be met any more. The manufacturer takes no 
responsibility in this case. 

User Manual: PS020A

 

DMX-controlled 3-CHANNEL Power Supply     

 

 

 

 

V1.00 (06-2007) © Multiform, Leigh-on-Sea, UK                                                                                               

13

 

The pre-programmed soft fade or hard switching patterns can be chosen by means of 
CH1 whilst CH2 is used as a dimmer channel. CH3 allows to set the fade time or 
pattern speed from slow (value 50) to very fast (value 255). If channel 4 reaches a DMX 
value of 50 or above a strobe will be added to the chases. The strobe speed can be 
adjusted from slow (value 50) to 23 flashes per second (value 255). 
 

Note:  

Whether the unit works in static colour mode or pattern mode only depends on 

the value of channel 3. So make sure the value of channel 3 is lower than 50 to be in 
static colour mode. Otherwise you will be in pattern mode.  
 
In this mode the potentiometer (1) is disabled.  
 
Addressing has to be done as follows: 
 
001  first device    

(CH 1-4)  

*factory default* 

005  second device   

(CH 5-8) 

009  third device   

(CH 9-12)  

013  fourth device  

(CH 13-16)  

and so on. 

 
This setting is stored even if the device is switched off. 

 

 

 
Display on/off 

 
If you wish the display to be lit only when a change in operation is made, the DIP switch 
(10) should be in the position off. Now if any of the buttons is not pressed for more than 
approximately 25 seconds the display is switched off. As soon as one of the buttons is 
pressed again, the display switches on immediately. In this case the first touch of the 
button is ignored in respect to the normal function of that button.

 

 
 

Key lock 

 

Pressing the MODE button (5) for longer than 3 seconds locks all the buttons (5-7) and 
the potentiometer (1). The display shows “LOC” in alteration to the mode (changing 
every 2 seconds). Pressing the MODE button again for more than 3 seconds unlocks 
the button- and potentiometer-functions. Please note: If the display is in OFF-mode it 
will take approximately 25 seconds before the display switches off. It will be switched 
on again if any key is touched and will switch off again after 25 seconds if the keys are 
not unlocked by the procedure mentioned above.  
 
 

Termination 

 
To avoid interference the last unit of a DMX-chain should be terminated. Therefore the 
DIP switch (9) of the last unit in the DMX-chain must be switched ON.  

Содержание PS020A

Страница 1: ...installations fix the unit with self locking screws nuts to the mounting point When mounting the unit to truss be sure to secure an appropriately rated clamp to the hanging yoke using a M10 screw fitt...

Страница 2: ...sive RGB LED panel For extended user advice please refer to the respective panel s user manual Security advice before use Warning Read this section carefully before installing powering operating clean...

Страница 3: ...C mains voltage inside the unit The exclamation mark within an equilateral triangle makes you aware of important operating and maintenance instructions in the literature attached to this product 5 Tak...

Страница 4: ...CE and FCC requirements A corresponding sign is printed on the backside of the unit Any change or modification may affect the behavior of the unit concerning electromagnetic radiation with the CE requ...

Страница 5: ...105 Soft fade turquoise pink 226 240 Hard switch red green blue 106 120 Soft fade red green blue 241 255 Hard switch red yellow green 121 135 Hard switch red green turquoise blue pink DMX Value range...

Страница 6: ...f from sliding off Use the two black screws 4 Plug in the mains cable to the unit and verify the display shows A1 NOTE A1 is only shown if no external DMX signal is supplied to the unit Connect extern...

Страница 7: ...de SLA NOTE The C Mode is automatically disabled and can not be chosen when an external DMX signal is received DMX indicator LED 3 is lit If you leave mode C for any reason and come back later into mo...

Страница 8: ...is received DMX indicator LED 3 is lit Whilst being in pattern A 1 static scene turning knob 1 determines the colour whereas being in one of the other 26 patterns knob 1 controls the speed or selects...

Отзывы: