User Manual: LS4195
DMX-controlled RGB LED 4-Spot T-Bar
V1.00 (01-2010) © Multiform Lighting
4
damage by foot steps or by squeezing it. Take especially care of
the AC cord outlet on the unit as well as the AC plug and wall outlet
at the other end of the cable.
8. Do not open the unit for service purpose, as there are no user-
serviceable parts inside. Warranty will be void in any case of
unauthorized service by the user or other not authorized persons.
Protection from fire:
1. Take care of not placing the unit near sources of heat (e.g.
powerful amplifiers, fog machines).
2. Allow at least about 6” (15cm) between this unit and other devices
or a wall to allow for proper cooling.
3. Be sure this fixture is kept at least 0.5m away from any flammable
materials (decoration etc.).
4.
Do not stick filters, masks or other materials directly on the LEDs or
the LED cover screen.
5. Take always care of sufficient air convection in the unit’s
environment to avoid overheating, especially when mounting in a
closed environment. Make sure air convection slots are not
blocked. Do not operate this unit in environmental temperatures
exceeding 35 degrees Celsius.
6. Check the total maximum power of your AC wall outlet if you
connect several units to one wall outlet and avoid any overloading.
Protection from injury and damage:
1. Never use any accessories or modifications not authorized by the
manufacturer of this unit.
2. Choose a location for operation where the unit is protected from
vibration and where a fixed mounting position is provided. In case
of overhead-mounting, follow appropriate rigging rules and your
country’s regulations for rigging safety. See appendixes if any.
3. Before plugging the AC cord in the wall outlet, check whether the
AC mains voltage and frequency is the same as this product is
specified for. Whenever your AC plug should not match the wall
outlet, contact you dealer immediately.
4. If fluids have spilled into the unit or small parts have intruded the
unit, immediately switch off the unit and hand it over to the
authorized service for a security check.
5. Disconnect the unit from AC supply by pulling the AC plug out of
the wall outlet or the unit’s AC socket during a thunder-storm in
order to avoid any damage on the unit due to AC voltage peaks.
6. In cause of not correct function of this unit or damaged AC cord or
other damaged parts, pull immediately the AC plug out of the wall
outlet and hand the unit over to the authorized service for a
security check.
7. To meet all aspects of functionality and security during mainte-
User Manual: LS4195
DMX-controlled RGB LED 4-Spot T-Bar
V1.00 (01-2010) © Multiform Lighting
13
Addressing has to be done as follows:
001 first device
(CH1-16)
017 second device
(CH17-32)
033 third device
(CH33-48) and so on.
The DMX channel setting is stored even when the device is switched off.
“P” Mode (DMX Preset Mode)
Press the MODE button (5) until the display shows “P”, indicating that the unit is on “P”
(DMX Preset) mode. This mode allows you to remotely control the internal presets by
an external DMX controller. In this mode, the unit receives DMX values on a packet of
five channels, and mirrors the received data on the DMX output. Depending on whether
CH3 is set to <50 or
≥
50, the five channels control the unit either in static or dynamic
(chaser) configuration as follows:
Static Configuration
– fixed colours (CH3 < 50)
CH1:
colour / colour pattern with following mapping:
DMX from
DMX to
Mapping
DMX from
DMX to
Mapping
000 008
C01
133 141 C16
009 017
C02
142 150 C17
018 026
C03
151 158 C18
027 035
C04
159 167 C19
036 044
C05
168 176 CP0
045 052
C06
177 185 CP1
053 061
C07
186 194 CP2
062 070
C08
195 203 CP3
071 079
C09
204 211 CP4
080 088
C10
212 220 CP5
089 097
C11
221 229 CP6
098 105
C12
230 238 CP7
106 114
C13
239 247 CP8
115 123
C14
248 255 CP9
124 132
C15
CH2: Brightness
CH3: <50,
unused
CH4: Strobe
speed
CH5:
Strobe pattern, with following mapping:
DMX from
DMX to
Mapping
DMX from
DMX to
Mapping
000 042
All
on
128 170 Run
right
043 085
in
/out
171 213 Run
left
086 127
left
/
right
214 255 Random