Multiform LS4195 MultiBar Скачать руководство пользователя страница 4

User Manual: LS4195

 

DMX-controlled RGB LED 4-Spot T-Bar             

 

 

 

 

V1.00 (01-2010) © Multiform Lighting                                                                                                                  

4

 

damage by foot steps or by squeezing it. Take especially care of 
the AC cord outlet on the unit as well as the AC plug and wall outlet 
at the other end of the cable.  

8.  Do not open the unit for service purpose, as there are no user-

serviceable parts inside. Warranty will be void in any case of 
unauthorized service by the user or other not authorized persons.  

 

 

Protection from fire: 

1.  Take care of not placing the unit near sources of heat (e.g. 

powerful amplifiers, fog machines). 

2.  Allow at least about 6” (15cm) between this unit and other devices 

or a wall to allow for proper cooling. 

3.  Be sure this fixture is kept at least 0.5m away from any flammable 

materials (decoration etc.).  

4. 

Do not stick filters, masks or other materials directly on the LEDs or 
the LED cover screen. 

 

5.  Take always care of sufficient air convection in the unit’s 

environment to avoid overheating, especially when mounting in a 
closed environment. Make sure air convection slots are not 
blocked. Do not operate this unit in environmental temperatures 
exceeding 35 degrees Celsius.  

6.  Check the total maximum power of your AC wall outlet if you 

connect several units to one wall outlet and avoid any overloading. 

 

 

Protection from injury and damage: 

1.  Never use any accessories or modifications not authorized by the 

manufacturer of this unit. 

2.  Choose a location for operation where the unit is protected from 

vibration and where a fixed mounting position is provided. In case 
of overhead-mounting, follow appropriate rigging rules and your 
country’s regulations for rigging safety. See appendixes if any.  

3.  Before plugging the AC cord in the wall outlet, check whether the 

AC mains voltage and frequency is the same as this product is 
specified for. Whenever your AC plug should not match the wall 
outlet, contact you dealer immediately. 

4.  If fluids have spilled into the unit or small parts have intruded the 

unit, immediately switch off the unit and hand it over to the 
authorized service for a security check. 

5.  Disconnect the unit from AC supply by pulling the AC plug out of 

the wall outlet or the unit’s AC socket during a thunder-storm in 
order to avoid any damage on the unit due to AC voltage peaks. 

6.  In cause of not correct function of this unit or damaged AC cord or 

other damaged parts, pull immediately the AC plug out of the wall 
outlet and hand the unit over to the authorized service for a 
security check.  

7.  To meet all aspects of functionality and security during mainte-

User Manual: LS4195

 

DMX-controlled RGB LED 4-Spot T-Bar             

 

 

 

 

V1.00 (01-2010) © Multiform Lighting                                                                                                                  

13

 

Addressing has to be done as follows: 
001  first device    

(CH1-16) 

017  second device   

(CH17-32) 

033  third device   

(CH33-48) and so on. 

 
The DMX channel setting is stored even when the device is switched off.  

 
 
“P” Mode (DMX Preset Mode) 

 
Press the MODE button (5) until the display shows “P”, indicating that the unit is on “P” 
(DMX Preset) mode. This mode allows you to remotely control the internal presets by 
an external DMX controller. In this mode, the unit receives DMX values on a packet of 
five channels, and mirrors the received data on the DMX output. Depending on whether 
CH3 is set to <50 or 

50, the five channels control the unit either in static or dynamic 

(chaser) configuration as follows:  
 

Static Configuration

 – fixed colours (CH3 < 50) 

 
CH1: 

colour / colour pattern with following mapping: 

 

DMX from 

DMX to 

Mapping 

 

DMX from 

DMX to 

Mapping 

000 008 

C01  

133 141 C16 

009 017 

C02 

  

142 150 C17 

018 026 

C03 

  

151 158 C18 

027 035 

C04 

  

159 167 C19 

036 044 

C05 

  

168 176 CP0 

045 052 

C06 

  

177 185 CP1 

053 061 

C07  

186 194 CP2 

062 070 

C08  

195 203 CP3 

071 079 

C09  

204 211 CP4 

080 088 

C10  

212 220 CP5 

089 097 

C11  

221 229 CP6 

098 105 

C12  

230 238 CP7 

106 114 

C13  

239 247 CP8 

115 123 

C14  

248 255 CP9 

124 132 

C15 

 

 

 

 

 
CH2: Brightness 

 

CH3: <50, 

unused 

CH4: Strobe 

speed 

CH5: 

Strobe pattern, with following mapping: 

 

DMX from 

DMX to 

Mapping 

 

DMX from 

DMX to 

Mapping 

000 042 

All 

on 

 

128 170 Run 

right 

043 085 

in 

/out 

 

171 213 Run 

left 

086 127 

left 

right 

 

214 255 Random 

Содержание LS4195 MultiBar

Страница 1: ...AC90 250V 50 60Hz Power supply type switch mode Power Consumption max 55 2W Fuse 250V 2A T slow blow 5x20mm glass Sound control internal microphone with Automatic Gain Control AGC DMX connections 3 p...

Страница 2: ...GB LED 4 Spot T Bar V1 00 01 2010 Multiform Lighting 15 Display on off If you wish the display to be lit only when a change in operation is made the DIP switch 8 9 should be in the position off Now if...

Страница 3: ...duct 2 Keep this manual in your records for future reference 3 Follow all instruction printed in this manual otherwise warranty may be void 4 Follow all printed security advice on the product itself T...

Страница 4: ...to the unit or small parts have intruded the unit immediately switch off the unit and hand it over to the authorized service for a security check 5 Disconnect the unit from AC supply by pulling the AC...

Страница 5: ...3 by CH5 8 Spot 2 by CH9 12 and Spot 1 by CH13 16 In this mode the rotary control 1 is disabled Also the settings of the DIP switches 5 6 7 9 are disabled To indicate that the unit is controlled by an...

Страница 6: ...installation yourself Improper installation can result in body injury Be sure to complete all rigging and installation procedures before applying power to the unit User Manual LS4195 DMX controlled RG...

Страница 7: ...rolled RGB LED 4 Spot T Bar can be truss mounted by means of two M10 mounting points which are located on the top of the unit In case of permanent use of these mounting points instead of tripod mounti...

Страница 8: ...tor 14 Power Input 90 250V AC Upon the user s choice the unit can work stand alone or may be controlled by external DMX controllers Available modes F Mode Auto Fade DMX Master Press the MODE button 5...

Отзывы: