background image

INTRODUCTION..………….........………...….....…..……………………………………………….……..…..............……1 

FEATURES AND OPERATION…...........…………………………………………..........…….......................………2 - 4

 

 

CAM HUT (CAM SIDE).............................………...........………..………..………..……….....………....…2 

 

FRONT PANEL FEATURES..........................………...........………..………..………..……….....……….…2 

 

 

OPTIONAL FRONT PANEL FEATURES....………...........………..………..………..……….....………....…3 

 

REAR PANEL FEATURES..........................………...........………..………..………..……….....………....…3 

 

CONFIGURING THE OPERATION VOLTAGE..........................………...........……….....………....…3 

 

BASE (CCU SIDE) UNIT…………………………...............................………...........……….....……….…3 - 4 

TECHNICAL SPECIFICATIONS......................….......………………………….........................………………....…5

TABLE OF CONTENTS

Содержание SMPTE-HUT

Страница 1: ... 877 685 8439 516 671 7278 FAX 516 671 3362 sales multidyne com www multidyne com INSTRUCTION MANUAL HUT Hybrid Universal Transceiver SMPTE Hybrid Cable Elimination System for Broadcast Camera Systems MultiDyne Harnessing The Power of Light ...

Страница 2: ...ULTIDYNE Electronics Inc Hauppauge New York Printed in the United States of America All Rights Reserved Contents of this publication may not be reproduced in any form without the written permission of MULTIDYNE Electronics Inc This product was designed and manufactured in the UNITED STATES of AMERICA ...

Страница 3: ...RES AND OPERATION 2 4 CAM HUT CAM SIDE 2 FRONT PANEL FEATURES 2 OPTIONAL FRONT PANEL FEATURES 3 REAR PANEL FEATURES 3 CONFIGURING THE OPERATION VOLTAGE 3 BASE CCU SIDE UNIT 3 4 TECHNICAL SPECIFICATIONS 5 TABLE OF CONTENTS ...

Страница 4: ...tes in this manual Always adhere to local building safety and fire prevention codes during the installation and operation of this product Use only power cords specified for this product and certified for the country of use Connect the unit only to a power source with the specified voltage rating Use only fuses of the type and rating specified In case of an emergency ensure that power is disconnect...

Страница 5: ...n the rear panel instead as shown in Fig 3 In systems with the optional optical repeater it is important that the user be sure that his up link and down link signals are matched to the proper connectors consistently throughout the link Front Panel RESET This button resets a 2A thermal circuit breaker in series with the SMPTE hybrid connector output In the event of an over current fault that causes...

Страница 6: ...ule that accepts an IEC cord and a primary power switch If the optical connectors are located on the front panel as shown in Fig 2 then the rear would be completely blank except for the power entry If pressing the RESET button after an over current fault has occurred does not restore power please check the fuse Configuring the Operating Voltage The unit is configurable for either 115 or 230V opera...

Страница 7: ...ch Settings SW1 SW2 SW3 SW4 SW5 SW6 SW7 Ikegami down up up up down up up Hitachi down up up up up up up Sony down up up up up down down Panasonic 3500 or 3800 up down up down up up up Panasonic 3000 or 5000 down up down up up up up CCU Unit HUT BS Front Panel Camera Select BAT HANDLE Switch Settings SW1 SW3 SW4 SW5 SW6 SW7 Ikegami down up up down up up Hitachi down up up up up up Sony down up up u...

Страница 8: ...ail Electrical Output CAM HUT Unit 230VAC up to 250VA active 24VAC up to25VA standby Certifications FCC class B and UL CE Mechanical Environmental Dimensions LxWxH Weight HUT CP 11 25 x 5 75 x 3 5 inches 10 3 lbs Operating Temperature 0 to 70 deg C Power Requirement CAM HUT Unit 115 230VAC 50 60HZ 260VA Optical Connectors CAM HUT SMPTE 311 Plug 2 ST UPC or LC HUT BS BA CS CA 7 x 2 5 x 2 inches 0 7...

Отзывы: