OPERATION

MAINTENANCE

• 

Cut the reflective adhesive tap provide into approx 12mm (0.5″) squares and apply one 

square to each rotation shaft.

NOTE: The non-reflective area must always be greater than the reflective area.

• 

If the shaft is normally reflective, it must be covered with black tape or black paint 

before attaching reflective tape

• 

The shaft surface must be clean and smooth before applying reflective tape.

•  Depress the “MEAS” button and align the visible light beam with the applied target

•  Verify that monitor indicator lights when the target aligns with the beam. 

•  The current mode is the last time mode used. If you need to change the mode, release 

the “MEAS” button and press the “MODE” button before the instrument auto powers off 

to switch between “RPM” and “REV”  (revolution).

•  Select the mode of you require, then press the “MEAS”  to start readings.

NOTE: This instrument will auto power off in 10 sec after releasing the “MEAS” button.

•  Press the “MEM” button displays the reading of the Max, Min and Last value for the 

previous measurement taken. 

VERY LOW RPM MEASUREMENT

•  Measuring high resolution and fast sampling time is easier than measuring slow RPM.

•  If measuring very low RPM values, it is suggested to attach more “REFLECTIVE 

MARKS” spaced around the shaft

•  Then divide the reading shown by the number of “REFLECTIVE MARKS” placed to get 

the correct RPM value.

Replacing the battery

•  When the meter display fades the battery needs changing.

•  Open the battery cover on the rear case.

• 

Remove the old battery and fit a new 9V PPA battery into the battery holder noting the 

correct polarity of the connector.

•  Replace the battery cover.

 

Cleaning

•  Clean the meter with a clean, soft cloth.

•  Do not use any chemicals, abrasives or solvents that could damage the meter.