multicomp pro MP700110 Скачать руководство пользователя страница 10

 

10 

6,Read the voltage in the display.  

DC/AC VOLTAGE MEASUREMENTS:

 If the polarity is 

reversed, the display will show (-) minus before the value 

 

VIII. 200k



RES IS TANCE MEAS UREMENTS

 

 1, Set the function switch to the highest 

200k

 position.  

2, Insert the black test lead banana plug into the negative 
COM jack 
3, Insert the red test lead banana plug into the positive 

 jack. 

4, Touch the test probe tips across the circuit or part under 
test. It is best to disconnect one side of the part under test so 
the rest of the circuit will not interfere with the resistance 
reading. 

5, Read the resistance in the display 

 

 

X. Battery Replacement 

1,When the low battery symbol

appears 

on the LCD, 

the six 1.5V ‘AA’ batteries must 

be replaced. 
2, Turn the meter off and remove the test 
leads. 
3, Unclip the tilt stand from the rear of the 
meter. 
4, Remove the four Phillips head screws 
holding the battery cover. 

5, Remove the battery compartment cover

6, Replace the batteries observing polarity. 

7, Affix the rear cover and secure the screws.

 

8, Reattach the tilt stand. 

Содержание MP700110

Страница 1: ...200k 750V 1000V 1000 100 10 HOLD TEST DIGITAL EARTH RESISTANCE TESTER MP700110...

Страница 2: ...stries telecommunication networks and electrical traction systems etc I SAFETY INFORMATION Read the following safety information carefully before attempting to operate or service the meter To avoid da...

Страница 3: ...tages Meter is protected throughout by double insulation or reinforced insulation When servicing use only specified replacement parts CE Complies with EN 61010 1 II FEATURES Earth resistance range 20...

Страница 4: ...C to 60 C 14 F to 140 F and Humidity below 70 RH Power source 6x1 5V Size AA battery or Equivalent DC9V Dimensions 200 L x 92 W x 50 H mm Weight Approx 700g include battery Accessories 4 sets Test ki...

Страница 5: ...verload Protection 1000V 1V 0 8 3d 10M 1000Vrms AC Voltage 40Hz 400Hz Range Resolution Accuracy Input Impedance Overload Protection 750V 1V 1 2 10d 10M 750Vrms V PARTS CONTROLS Digital Display Data Ho...

Страница 6: ...in the display Press the HOLD key momentarily to activate or to exit the hold function Backlight Press the key for to turn on the display backlight function The backlight will automatically turn off...

Страница 7: ...ch to EARTH WOLTAGE position and press to test Earth voltage will displayed on the LCD When earth voltage is more than 10V it may result in errors in earth resistance measurement Accurate earth resist...

Страница 8: ...2 2 Rotate the function switch to EARTH VOLTAGE position and press to test Make certain that earth voltage is less than 10V 3 First rotate the function switch to 200 position and press to test read ea...

Страница 9: ...ply with an ELCB is used Follow the proper connection such as Fig1 VII DC AC VOLTAGE MEASUREMENTS 1 Set the function switch to the highest 1000V DC or 750VAV position 2 Insert the black test lead bana...

Страница 10: ...under test It is best to disconnect one side of the part under test so the rest of the circuit will not interfere with the resistance reading 5 Read the resistance in the display X Battery Replacemen...

Страница 11: ...ts life it must be treated as Waste Electrical Electronics Equipment WEEE Any WEEE marked products must not be mixed with general household waste but kept separate for the treatment recovery and recyc...

Отзывы: