DNC Mode
The DNC Mode function is used to allow the operator to toggle back and forth between local and remote DNC
Modes. Local mode allows the operator to review what files have been saved in the controller, and remote mode
allows the operator to run programs. The system must be set to remote mode to run the file.
The DNC Mode can create a shortcut for commonly used files without the operator having to enter the Utility
sub-menu each time. The controller memory allows a maximum of 20 job files or a limited amount of memory
space for large job files to be saved to the controller. The display will indicate when the memory capacity is full
with a notice showing
Error Writing File; Out of Room
. The operator will need to delete a job file from the
controller memory before adding any new job files.
1. Press
Menu
to access the menu system.
2. Press
X-axis Jog Arrows
until Utility is highlighted in blue.
3. Press
Enter
to access the Utility sub-menu.
4. Press
X-axis Jog Arrows
until DNC Mode is highlighted in blue.
5. Press
Enter
to access the DNC mode. An X will be located to the left of the mode currently being run.
6. Press
X-axis Jog Arrows
to move between the DNC Modes. Local mode shows what files have
been saved to the controller while the remote mode shows what files are available in the PC.
7. Press
Enter
to accept the selected mode and return to the main display.
Saving Files to Controller DNC
1. Make sure the DNC mode is set for local.
2. Press
Shift
and
DNC
to access the list of files available in the PC.
Routers * Lasers * Plasma * WaterJets * Knife Cutters