6.  CHANGING LIGHT SHAPERS 

All Multiblitz light shapers have a bayonet mount and can be locked in the units´ 

bayonet. Unlock the reflector lock on the bottom side of the unit by pushing it 

towards the control panel, insert the desired light shaper in the mount, and turn 

clockwise to lock. To remove a light shaper, proceed in the reverse order. Use 

umbrellas exclusively with the PLUSCH umbrella reflector, which includes the 

umbrella holder.

7.  CHANGING THE HALOGEN- AND FLASH TUBES 

Switch off the unit by pressing and holding the „I-0“ button while firing a flash by 

pressing the „TEST“ button, then let go of the „I-0“ button. Pull the mains cable. 

Should the unit fail to fire, wait for at least 45 minutes to make sure that the capacitor 

is fully discharged and the flash tube can be touched without any risk. Remove the 

light shaper from the unit (see “6. Changing light shapers“). Gently push the halogen 

tube inwards, turn it counterclockwise and pull it out of its socket. Put in the new 

halogen tube and secure it by turning it clockwise (Follow the manufacturer’s  

instructions). Pull out the flash tube by gripping it by its glass. (Watch out for hot  

parts and be sure not to touch the electrodes!) Carefully insert the new tube.  

The firing clamp should embrace the glass and be in contact with the triggering wire.

8.  AUTOMATIC TEMPERATURE CONTROL 

The unit is equipped with a temperature control which switches off the flash-  

and the halogen light as soon as the units’ inside temperature rises over approx.  

50° C. When the unit has cooled-off, all functions are being switched on auto-

matically by the temperature control, again. However, temperatures of over 50° C 

are only being reached under extreme circumstances like direct, long-term  

solar radiation together with an extremely high flash count and very brief flash 

repetitions. The unit will not overheat when used in a usual studio set-up.

9.  FUSES 

To change fuses, switch the unit off and pull the power plug. Fuse box: Push the 

fuse box out towards the front with the aid of small screwdriver placed behind 

the upper part of the box. The fuse is located at the rear, a spare fuse at the front 

of the box. Always replace the blown fuse by one with an identical rating: 

 

110 - 130 V = T 4 A

Why does the unit not fire when I try to sync it to my camera using a sync lead?

Check if the sync lead is properly connected to the sync socket of the Profilux Eco and to your 

camera.

 

 

Why does the unit not fire when I try to sync it to my camera using the RS 2 radio trigger?

Check if a receiving channel of the wireless receiver is active, see page 7 point 5 and if the  

RS 2 trigger is properly connected to your camera.

 

 

Why does the unit not fire when I try to sync it to my camera using the MUSEN infrared trigger?

Check if the “IR/Slave Cell On-Off” button is switched on, see page 7 point 4 and if the 

infrared trigger is properly connected to your camera. 

Why does the housing above the control panel heats up a bit during stand-by?

The top side of the unit is where the power supply sits. Determined by the system it gets warm 

to the touch during stand-by mode.

Why does the unit sometimes fire when I turn down the output control to often  

in a short period of time?

The unit has to dissipate excess energy every time the output control is being turned down.

 

Why can I not focus my COMSCH umbrella reflector when using it with a Profilux Eco unit?

The housing size of the Profilux Eco units differ from older Multiblitz units. Use the new 

PLUSCH umbrella reflector with the Profilux Eco.

Can I run my Profilux Eco unit/s on a Multiblitz PROPAC 1 or PROPAC 2 battery pack?

No, the Profilux Eco must not be run on a PROPAC 1 or PROPAC 2 battery pack.