Chapter 9 – Response Messages and Error Codes
Multi-Tech Systems, Inc. AT Commands for Wireless Modems with IP Connectivity (S000333D)
42
Chapter 9 - Response Messages and
Error Codes
Response Messages
Standard AT Messages
Numeric
Verbose
Description
0
OK
Operation or command success
3
NO CARRIER
No physical layer connection
7 BUSY
Destination
busy
8
NO ANSWER
No answer from destination
4
ERROR
Operation or command unsuccessful
2
RING
Incoming call indication
10
CONNECT 300
Physical layer connected at 300 baud
11
CONNECT 1200
Physical layer connected at 1200 baud
12
CONNECT 1200/75
Physical layer connected at 1200/75 baud
13
CONNECT 2400
Physical layer connected at 2400 baud
14
CONNECT 4800
Physical layer connected at 4800 baud
15
CONNECT 9600
Physical layer connected at 9600 baud
16 CONNECT
14400
Physical layer connected at 14400 baud
Information Messages
Numeric
Verbose
Description
1025 OK_Info_DataBegin
Start of data
1028 OK_Info_WaitingForData
Send
data
3074 OK_Info_SocketClosed Socket
connection closed successfully
3072
OK_Info_NoMail
No mail to retrieve on server
3073
OK_Info_Mail
Mail ready to be retrieved on server
3077
OK_Info_PPP
PPP connection successful
3086
OK_Info_GPRSActivation
GPRS connection successful
Error Codes
Error Codes
Numeric
Description
34817
Bad command : Unknown command
34819
Bad command : Syntax error
34824
Bad command : EEPROM write failed
34881
Bad command : Command to long
34882
Bad command : Bad command argument value
35840
Physical layer : Modem is already running
35841
Physical layer : GPRS session lost
35862
Physical layer : Timeout, no activity on network connection
35865
Physical layer : Module is not attached to the network
35866
Physical layer : Invalid event during activation process
35867
Physical layer : Physical layer connection is currently not active
35868
Physical layer : GPRS connection aborted
35869
Physical layer : Invalid incoming call type
35870
Physical layer : Incoming call CLI not provided
36872
IP Connectivity library internal error : internal resource unavailable.
36929
IP Connectivity library : Bad parameter configuration attempt
37120
IP Connectivity library : PPP negotiation failed (client configuration)
37121
IP Connectivity library : PPP negotiation failed (server configuration)
37122
IP Connectivity library : Another internal application is already running
37123
IP Connectivity library : Service is running. Unable to set parameter
37952
Distant : TCP session closed (TCP Context cancelled)