MULTI MEASURING INSTRUMENTS MCL-350 Скачать руководство пользователя страница 1

 

 

AC CURRENT 

ANALOG CLAMP-ON TESTER 

 

MODEL    MCL-350 

 
 

INSTRUCTION MANUAL 

 

 

                            Thank you very much for selecting our digital AC clamp-on   
                            tester. 
                            This model is complex instrument and employ a very reliable 
                            mechanical/electronic design. 
                               

  Before you use your new instrument, read this Instruction 

                            Manual completely and familiarize yourself thoroughly with   
                            all functions. With proper use and care, your tester will give 
                            you years of satisfactory service.           
 
                               
 
 
 
 
 
                                    MULTI MEASURING INSTRUMENTS CO.,LTD. 
                                    Akihabara Murai Bldg. 7F, 1-26 Kanda Sakuma-cho, 
                                    Chiyoda-ku, Tokyo, Japan, 101-0025 
                                    TEL : +81-3-3251-7016    FAX : +81-3-3253-4278 
                                    Home Page : 

http://www.mutimic.com/

 

                                    E-mail : 

[email protected]

 

 
 
 
 
 
 
 

Содержание MCL-350

Страница 1: ...Before you use your new instrument read this Instruction Manual completely and familiarize yourself thoroughly with all functions With proper use and care your tester will give you years of satisfact...

Страница 2: ...o factories buildings etc Before operating this instrument familiarize yourself with all instructions outlined in this manual Always check to make sure that the function switch is set to the proper po...

Страница 3: ...enter Accuracy 3 of scale length Analog data output for recorder DC 100mV for full scale Operating temperature 0 to 40 80 RH non condensing Strange temperature 10 to 60 70 RH non condensing Power supp...

Страница 4: ...within the BATT mark the batteries are usable If the pointer indicates outside the mark the batteries are exhausted In this case replace the batteries with new ones Set the Zero 0 position of the poi...

Страница 5: ...e to the current to be measured Clamp the conductor of the circuit at the center of CT Read the current value of the current scale If you make measurements in a dark place or in a place where it is di...

Страница 6: ...TIMES OF THE NORMAL SUPPLY VOLTAGE THIS INSTRUMENT SHOULD NOT BE USED TO MEASURE POWER LINES The term of Power Line mean the electrical circuit providing the power to factories buildings and etc WARN...

Страница 7: ...tment knob Contact the tips of the test leads to the circuit under test Read the resistance on the scale Fig 3 CAUTION Be sure all voltage is turned OFF in the circuit before making resistance measure...

Страница 8: ...tteries or fuse remove all electrical inputs Do not replace the batteries under the conditions of clamping CT to the conductor and or inputting voltage to the terminals Do not use the mixed batteries...