MULTI MEASURING INSTRUMENTS M-2100 Скачать руководство пользователя страница 4

 
 
3. DIMENSIONS AND PANEL FUNCTION       

                   
 

Current transducer(Jaw) 

Jaw opening lever 

   

Power switch 

   

Range selector switch 

Data hold switch 

   

LCD display 

   

Input terminal(V) 

COM terminal 

Input terminal(

Ω

)(

     

)

 

Battery cover 

11

Wrist strap 

                                           

                 

 
 
 
 
 

                                           

                 

 

4. METHOD OF MEASUREMENT 
 

4-1. Measurement of AC Line Current (

A) 

       

 

 

① 

Press the power switch "ON". 

② 

Set the range selector switch to the proper   

ACA range to be measured.   
Start the measurement at top range and   
then work down to lower range. 

③ 

Open the CT and clamp it to the conductor   
to be measured at the center of CT.                                               

Close CT completely. 

④ 

Read the current value on the display. 

⑤ 

If you make measurements in a dark place   

or in a place where it is difficult to see the   
readings, use the data hold switch.                                                  Fig.1 

                                                                                                                             

Note : Clamp around only one conductor of the circuit to be measured. (See Fig.1)                                                 

When making the clamp measurements for high AC current, the noise sound 
of CT may be caused, however, this is not abnormal. 
 
 
 
 
 

 

Содержание M-2100

Страница 1: ...lectronic design Before you use your new instrument read this Instruction Manual completely and familiarize yourself thoroughly with all functions Keep this manual carefully to take out whenever you n...

Страница 2: ...nd etc Before operating this instrument familiarize yourself with all instructions outlined in this manual Always check to make sure that the function switch is set to the proper position When making...

Страница 3: ...ower off The meter is set to power off mode approx 10 minutes after the power switch on Operating temperature 0 to 40 80 RH non condensing Strange temperature 10 to 60 70 RH non condensing Power suppl...

Страница 4: ...nge to be measured Start the measurement at top range and then work down to lower range Open the CT and clamp it to the conductor to be measured at the center of CT Close CT completely Read the curren...

Страница 5: ...n Connect the plug of red test lead into the V terminal and the plug of black test lead into the COM terminal Set the range selector switch to ACV range Contact the tips of the test leads to the circu...

Страница 6: ...to rain or moisture Do not operate the tester in the presence of flammable gases or fumes CAUTION To avoid damage to the tester disconnect test leads before changing functions Do not exceed the maximu...

Страница 7: ...TION Be sure all voltage is turned OFF in the circuit before making diode test 5 REPLACEMENT OF BATTERIES AND When the battery voltage falls below a specified voltage value the B mark will appear in t...

Страница 8: ...sufficient internal inspections but if you find any defect due to the fault in our workmanship or the original parts please contact the dealer where you bought the instrument The warranty period is 12...

Отзывы: