3-2 Battery Installment 

 

 WARNING 

 

 

 

 

 

 

 CAUTION 

 

 

 

 

 

  “B” sign will appear on the display when batteries are exhausted and get less than 

operation voltage. Replace to new batteries immediately. 

  Do not use the batteries mixed new one and once used and or different kind ones. 

 

[How to replace the batteries] 

1.  Remove the screw fixing battery cover at the 

bottom of rear case by plus driver and slide 

& remove the battery cover to the direction 

of arrow mark. 

2.  Pick up the exhausted batteries. 

3.  Confirm the polarities and put the new 

batteries. 

4.

  Replace the battery cover to the original 

position and fix screw by driver.

 

 

 
 
 
 
 

POSSIBLE ELECTRICAL SHOCK OR ACCIDENT 

  Do not replace the batteries under the conditions of measuring current or 

voltage 

  Do not operate the instrument with battery cover off. 

When not using the instrument for a long period, remove the batteries and keep 

separately. The batteries may leak and may cause damage to the instrument. 

Battery Cover 

AAA Alkaline Battery (LR-03) x 3 

Содержание M-140HC

Страница 1: ...instruction manual completely and apply this instrument correctly Keep this instruction manual carefully to take out whenever you need MULTI MEASURING INSTRUMENTS CO LTD Akihabara Murai Bldg 7F 1 26...

Страница 2: ...from mis operations WARNING POSSIBLE ELECTRICAL SHOCK This instrument is for the use of low voltage circuit Do not make measurements of power lines carrying more than AC 600V Before use check and conf...

Страница 3: ...ng Part Measuring Function AC Leakage Current loading current Phase current of hi voltage circuit measuring at low voltage corresponding field Measuring Method CT clamp method max applicable conductor...

Страница 4: ...Consumption approx 3 5mA approx 150h for continuous use Dimension Weight 45 W x195 H x24 D mm approx 180g Accessories AAA battery LR03 x 3 installed in the instrument instruction manual x 1 soft carry...

Страница 5: ...h By push one time DH sign will be on LCD and the data will be hold By push once more this function will be released m Conversion Switch In case of hi voltage phase current measurement the storey capa...

Страница 6: ...ve the battery cover to the direction of arrow mark 2 Pick up the exhausted batteries 3 Confirm the polarities and put the new batteries 4 Replace the battery cover to the original position and fix sc...

Страница 7: ...r range OL mark will appear on LCD use data hold where displayed value cannot be seen clearly POSSIBLE ELECTRICAL SHOCK For safety use the instrument in circuit less than 600V Before operation confirm...

Страница 8: ...3 Phase Current Measurement of Hi Voltage Circuit with shielded grounding line 1 Measurement of CVT Cable In case of CVT cable as the right drawing this instrument can measure phase current by clampin...

Страница 9: ...nt of CV Cable Move CV cable to the search coil of CT like as at the right drawing and read the max value by keeping close and turning the instrument for 90o Set range switch from OFF to CV position d...

Страница 10: ...contact the dealer where you bought the instrument The warranty period is 12 months from the date of purchase and the instrument shall be repaired at free of charge provided that we judge the cause o...

Отзывы: