Muller HYDRO-GUARD 300 Series Скачать руководство пользователя страница 2

2

300 SERIES COLD CLIMATE FLUSHING SYSTEM

Installation Instructions

GENERAL

INSTALLATION

Site Evaluation

Each Hydro-Guard Unit installation 
is unique and will require a 
minimum of advance planning. Prior 
to the installation of the device, the 
drainage patterns for the intended 
installation location should be 
reviewed. The drainage pattern 
must permit discharged water to 
flow through a drain line away from 
the Hydro-Guard Unit. The 300 
Series Flushing System features 
threaded brass 1" inlet and 1" 
outlet connections. Installation will 
require the contractor to plumb 

Overview

The Hydro-Guard 300 Series Cold 
Climate Unit, is the industry’s only 
Below-Ground programmable flushing 
apparatus. This Unit is suitable for 
year-round use in cold climates. 
This Automatic Flushing System has 
been designed, engineered, and 
manufactured to provide outstanding 
dependability and performance.
Please read and retain this manual 
for future reference, training, 
troubleshooting, and maintenance.

Hydro-Guard 300 Series Cold 

Climate Flushing Unit

The Hydro-Guard 300 Series 

Cold Climate Unit is housed in a 

Mueller Thermal-Coil Meter Box 

that is approximately 21 inches 

in diameter. The bury depth will 

vary depending upon the depth of 

the utility’s water lines (Available 

Range: 48" to 120"). The box is 

constructed with low lead NTP 

male threads and is to be placed 

by the contractor at a location 

agreed upon by the end user. The 

box features coiled tubing that will 

route water from the water utility’s 

potable water distribution line to 

the meter assembly, through the 

300 Series’ flushing components, 

and discharge through a discharge 

service routed to an acceptable 

point of discharge (i.e., a storm 

sewer, swale, storm pond, etc.). 

The meter and flushing assembly 

can be raised for maintenance and 

repair and then lowered back down 

into the box below the frost line. 

A medium density foam insulation 

pad, freeze protection system, and 

composite lid (an optional cast 

lid is available) help protect the 

flushing and meter assembly from 

freezing in the winter.

      WARNING: Proper lifting, 

loading/unloading tools and 

techniques must be followed 

when handling this device. 

Damage to working components 

can occur if dropped.

the inlet water service line to the 
connection marked "inlet" and 
plumb the discharge line to the 
connection marked "outlet". The 
inlet service  and discharge water 
lines (by others) shall be installed 
at the same bury depth as the 
connections.  The discharge line 
should allow water to flow away 
from the Unit. The recommended 
minimum slope for the discharge 
piping is ½" per foot. The 
recommended final discharge points 
may include a storm drain, drainage 
or retention pond, or a storm swale.

!

1.

 Remove the Hydro-Guard Unit 

from its packaging and inspect for 
possible damage during shipping.

2.

 Turn off the service line feed.

3.

 Excavate a suitably sized ditch 

ensuring it is connected on one side 
to the utility’s service line trench. 
Remove any debris that might 
create uneven pressure on the Unit. 

Compact the bottom of the hole 
in order to minimize settling after 
installation. Place #57 stone. Then, 
place non-compacted clean bedding 
material within the bottom of the 
hole. Provide a bed of crushed 
gravel approximately 6 inches thick 
or place bricks or cement blocks 
below the pit to allow for drainage 
and provide support.

TYPICAL INSTALLATION

Cast Iron Vault Lid

Double Check Valve

1" Mueller Systems 

Meter Sold Separately

8-Tablet Dechlorination

Supply
(By Others)

1" Male 
Thread Ends

Discharge (By Others)

Grade

Ground

Programmer

Содержание HYDRO-GUARD 300 Series

Страница 1: ...red by Mueller Co only and may not be applicable for any other use 2 DO NOT exceed the pressure ratings of any components or equipment Exceeding the rated pressure may result in serious injury and or property damage 3 Safety goggles and other appropriate protective gear should be used Failure to do so could result in serious injury 300 Series Cold Climate Flushing System Installation Instructions ...

Страница 2: ...point of discharge i e a storm sewer swale storm pond etc The meter and flushing assembly can be raised for maintenance and repair and then lowered back down into the box below the frost line A medium density foam insulation pad freeze protection system and composite lid an optional cast lid is available help protect the flushing and meter assembly from freezing in the winter WARNING Proper liftin...

Страница 3: ...sting grade and ensure the meter lid is level with existing grade 7 Place the pit in the excavated area and connect the inlet piping Hand tighten the fitting to the pit then turn two full turns with a wrench This will result in a leak tight connection without placing undue stress on the pit piping 300 SERIES COLD CLIMATE REQUIRES CONTROLLER Buetooth Programming Instructions The BL KR battery power...

Страница 4: ...pulate the device list can be found on the label located on the back of the controller housing with the designation Default name The App will indicate that it is in the process of connecting 8 Once the device is connected it will appear on the home screen when you launch the Application Application Home Screen Device Home Screen To add another controller tap the plus sign in the upper right hand c...

Страница 5: ... connector to controller 3 Make sure no water is inside battery compartment 4 Screw the NODE rear body back onto front half NOTE Make sure that seal marker on rear half of the NODE lines up with front half ensuring a proper seal is created Also The NODE has non volatile memory which allows battery replacement without losing program information Setting Date Time 1 Press RETURN ENTER key until CLOCK...

Страница 6: ...tart time in 15 minute increments 4 Press RIGHT ARROW key to add an additional START TIME to program displayed The start time number is shown in upper left corner of display 5 Press PRG key to add START TIME to a different program 6 Press RETURN ENTER key to proceed to next programming function or allow controller to return to idle mode Setting Flush Duration Times 1 Press RETURN ENTER key until H...

Страница 7: ...tirety in order to allow for required service and maintenance If disassembly is necessary please follow the directions below Always close the curb stop before working on the unit Disassembly 1 Shut off water supply to the unit and remove the green housing cover 2 Remove the composite or cast iron lid of 300 Series Cold Climate protective ground sleeve 3 Remove foam insulation pad 4 Using the lifti...

Страница 8: ...eaks or lack of connection Run a manual flush and confirm the solenoid plunger is kicking out and pulling back in by listening for a click Check connections for corrosion breaks or lack of connection Check the adapters and solenoid for debris Run the electrical systems check Refer to valve troubleshooting for possible corrective measures PROBLEM CAUSE SOLUTION Controller does not flush as desired ...

Страница 9: ...wo 9 volt alkaline batteries Tighten the cap completely to ensure a water tight fit The following is a brief overview and introduction to our options Integrated Sample Station The 300 Series Cold Climate Sub Surface Discharge Unit features a Sample Port quick connect that allows the end user to collect a sample from the 300 Series Cold Climate installation site To collect a sample from the sample ...

Страница 10: ...INE DECHLOR 3 HG 11010 1 HITVLVE 510 000 WITHOUT STEM 4 780029 2150 300 Series Cold 48 IN SHELL SUB ASSEMBLY 5 300Series BL BlueTooth Controller Programming Option 6 546784 HG8 CC 300 Series Cold CC PLATFORM ASSEMBLY 7 790119 21 IN INSULATING PAD 8 780034 1848 HG8 300 Series Cold Coil Sub Assembly 9 HG 2321 21IN STEEL PLATFORM HC 21 25A 1 2 3 7 4 5 6 8 9 ...

Страница 11: ...11 Notes 300 SERIES COLD CLIMATE FLUSHING SYSTEM ...

Страница 12: ... are liable only for their own acts and omissions and not those of each other MWP brands include Mueller Echologics Hydro Gate Hydro Guard HYMAX Jones Krausz Mi Net Milliken Pratt Pratt Industrial Singer and U S Pipe Valve Hydrant Please see muellerwp com brands and krauszusa com to learn more 2021 Mueller Water Products Inc All Rights Reserved The trademarks logos and service marks displayed in t...