![Muirhead 3508 Скачать руководство пользователя страница 7](http://html.mh-extra.com/html/muirhead/3508/3508_product-manual_1853661007.webp)
M0404.docx | Rev 1.8 | Modified on 26/09/2018 | © Remote Control Technologies Pty Ltd
7 | 16
Operation and Use
The system detects the speed of the vehicle via a proximity pickup sensor located in the drive train.
If
the vehicle’s speed exceeds the first preset level, an audible alarm will sound.
If the driver allows the vehicles speed to exceed the second preset limit, the alarm will continue to sound and
additional warning devices will be activated. Additional warning equipment can include strobe lights or flashing
indicators.
When the vehicle
’s speed is reduced and is below the first pre-set limit, the warning alarms will reset and the
speed alert system will return to normal status.
Installation Guide
1. Install the control unit in a suitable location, preferably within the instrument panel area of the forklift.
2. Run the wiring in the most suitable way to keep the wiring harness protected and out of the way of moving
parts.
3. Refer to the wiring tables below and the wiring diagrams on the following pages as a guide on how to wire
up the control unit and the wiring loom.
Note
If ordering a 3515 control unit to replace the module from the 8867 road speed limiter kit, you need to refer to
the 8867 product manual.
Wiring Connections
No.
Colour
Description
1
Red
Ignition 8
–30 Vdc
2
Black
Ground
3
White
Speed signal input
4
Orange
Relay 2 warning N/C (optional)
5
Green
Relay 2 warning N/O
6
Pink
Relay 1 warning N/C (optional)
7
Green/Yellow
Relay 1 warning N/O
8
Blue
Test/program