Содержание HYDRO GUARD HG-8 Standard

Страница 1: ...Page 1 of 28 HG 8 InGround Flushing System User Operation Manual Automatic Flushing Devices...

Страница 2: ...ly prohibited Congratulations on your purchase of the Hydro Guard HG 8 InGround Sub Surface Discharge Unit the industry s only patented programmable flushing apparatus suitable for year round use in c...

Страница 3: ...rocedures Site Evaluation Installation of the Unit 6 7 Installation Rendering 8 Programming Standard T2 9 12 Programming Signature NODE 13 15 Technical Section Unit Disassembly 17 Electrical System Ch...

Страница 4: ...mage to the device Each person involved in the assembly installation and or maintenance of the Hydro Guard Automatic Flushing Device must read this manual carefully and follow all instructions prior t...

Страница 5: ...Page 5 of 28 Installation Procedures Site Evaluation...

Страница 6: ...HG 8 s flushing components and discharge through a discharge service line which is routed to an acceptable point of discharge i e a storm sewer swale storm pond etc The meter and flushing assembly ca...

Страница 7: ...nd hand tamp each layer until the service grade is restored Step 10 After installation is complete sod the area around the Hydro Guard Unit or take other steps in order to prevent erosion Inspect the...

Страница 8: ...MBLY Complete 1 Valve and Meter Replacement Assembly 546779 1 Coiled Tubing Assembly Cast Iron Vault Lid 546787 HG8 Plate Rest 546799 21 Dia Below Grade Vault 790015 Reinforcing Ring 700014 2 Foam Ins...

Страница 9: ...infra red connector connected to the built in programming interface can significantly reduce the battery life of the 9 volt batteries in the programming interface and the rechargeable battery in the...

Страница 10: ...OK 6 Use UP DOWN ARROWS to select one of the following a Custom Cycle Week use RIGHT LEFT ARROWS to move to days of the week use ON OFF keys to highlight days on which to flush then press OK to confir...

Страница 11: ...A B or C from TBOS II infra red welcome screen use DOWN ARROW to select Programs and press OK then select what is to be checked and follow prompts Manual Flushing Using TBOS II handheld on the T 2 bui...

Страница 12: ...e built in interface s internal memory lasts only 3 minutes Any time the battery within the Programming interface fully discharges it is necessary to plug the Handheld Programmer directly into the int...

Страница 13: ...y will shut off to retain battery power Pressing any key will wake up the NODE to the Idle Mode Run Mode When controller is operating a program items shown on display will include station number alway...

Страница 14: ...corner of display 5 Press PRG key to add START TIME to a different program 6 Press RETURN ENTER key to proceed to next programming function or allow controller to return to idle mode Setting Flush Du...

Страница 15: ...hat station Pressing the button when a station is running in manual watering will stop irrigation on the current station and advance to the next station Pressing the button when a station is running i...

Страница 16: ...Page 16 of 28 Technical Section...

Страница 17: ...directions below Always close the curb stop before working on the unit HG 8 Machine Disassembly Step 1 Shut off water supply to the unit and remove the green housing cover Step 2 Remove the cast iron...

Страница 18: ...amming keys of the handheld run a 2 minute manual flush sequence Plunger inside solenoid should be down when running and up when off Step 4 To prevent the loss of the solenoid plunger and spring place...

Страница 19: ...ce when pulling plug out Step 6 Check for debris in the valve screen on the inlet side with the lower half of the valve body by removing the valve screen plug Step 7 Return valve plug to its proper lo...

Страница 20: ...lifting holes and or lifting strap on steel plate lower flushing metering assembly below grade by slowly lowering the steel mounting plate to the lower part of the in ground protective housing DO NOT...

Страница 21: ...ent Track your residual levels and alter flushing frequency and or duration in order to maximize water conservation Dechlorination The Hydro Guard HG 8 is equipped with a dechlorination system Dechlor...

Страница 22: ...ttery box out of the watertight housing Replace 9 volt battery with a 9 volt lithium battery Signature Style NODE Programming Unscrew cap from bottom of NODE programmer housing Insert two 9 volt alkal...

Страница 23: ...Page 23 of 28 HG 8 InGround Flushing System Sub Surface Discharge Unit Parts Section...

Страница 24: ...00 1 Backflow Double Check Valve 9 700507 U Bar 10 700507 Flow U Bar w Hole for FP 15 HG 11010 1 Flow Control Valve 23 HG A119 320 Inline Dechlor Assembly 24 HG FP100 Thermal Control Valve 25 HG FP108...

Страница 25: ...U Bar 700014 Threaded Connector 700261 Reinforcing Ring HG FP100 Anti Freeze Valve HG FP108C Molded Freeze Adaptor HG A119 320 Inline Dechlor HG V105 1 4 Polyurethane tube HG 20069 1 Flow Control Valv...

Страница 26: ...Page 26 of 28 Notes...

Страница 27: ...Page 27 of 28 Notes...

Страница 28: ...Manufacturing facilities in Cleveland TN The Advance Maintenance Flushing concept using Automatic Flushing Units as presented is patented in the United States and Canada Foreign patents pending Hydro...