5
Programming Unit
HG-6 FLUSHING SYSTEM
Programming
The NODE has the capability to
hold 3 programs (A, B, C) and 4
start times per program. When
programming, flashing portion
of display can be changed by
pressing
+
or
–
keys. To change
something not flashing, press
LEFT
or
RIGHT ARROWS
until desired
item is flashing.
Setting Date / Time
1.
Press
RETURN / ENTER
key
until
CLOCK
icon is displayed.
2.
All 4 digits will be displayed
representing the year. Use
+
or
–
keys to change year. Press
RIGHT
ARROW
key to proceed to setting
month.
3.
All 4 digits will be displayed
with two digits on left flashing
representing the
MONTH
.
Use
+
or
–
key to change month.
Press
RIGHT ARROW
key to
proceed to setting
DAY
.
4.
Only two digits on right will be
flashing, representing the
DAY
.
Press
+
or
–
key to change day.
Press
RIGHT ARROW
key to
proceed to changing
TIME
.
5.
The
AM / PM / 24
time
setting is shown flashing.
Press
+
or
–
key to change to
AM, PM, or 24-hour time. Press
RIGHT ARROW
key to proceed
to setting the
HOUR
.
6.
All 4 numbers are shown with
two numbers on the left flashing,
representing the
HOUR
. Press
+
or
–
key to change the hour.
Press
RIGHT ARROW
key to
proceed to setting
MINUTES
.
7
. All 4 numbers are shown with
two numbers on right flashing,
representing
MINUTES
. Press
+
or
–
key to change minutes.
(Pressing
RIGHT ARROW
key will
return to
YEAR
setting at step
#2.)
8.
Press
RETURN / ENTER
key to
proceed to next programming
function, or allow controller to
return to idle mode.
HG-6 BUILT-IN: (INTEGRATED)
NODE Programming Instructions
Batteries
The NODE uses standard 9-volt
alkaline batteries to operate the
control valve and program the
controller. The controller can
operate with one or two batteries
installed. Under normal conditions,
potential life is 1 year for a
single battery.
Battery Installation
1.
Unscrew rear body of the NODE
to gain access to battery
compartment.
2.
Insert battery / batteries into
battery tray and connect the
battery connector to controller.
3.
Make sure no water is inside
battery compartment.
4.
Screw the NODE rear body back
onto front half.
NOTE: Make sure that seal marker
on rear half of the NODE lines up
with front half, ensuring a proper
seal is created. Also, The NODE has
non-volatile memory, which allows
battery replacement without losing
program information.
Idle Mode – Waking Up
Normally the NODE display showstime
and day, day of week, and battery life
indicator. During a short period of
inactivity the display will shut off to
retain battery power Pressing any
key will wake up the NODE to the
Idle Mode.
Run Mode
When controller is operating a
program, items shown on display will
include station number (always “1”),
program letter (A, B, or C), remaining
runtime, and a blinking Rotor icon.
Setting Flush Sequence
Start Times
1.
Press
RETURN / ENTER
key until
CLOCK
icon is displayed.
2.
The
START TIME
will be
displayed flashing, along with the
program letter (A, B, or C) and
start time number (1, 2, 3, or 4)
in the upper left of the display.
Up to 4 different start times can
be set for each program.
3.
Use
+
or
–
key to change
START TIME
for program
displayed. Each press of key will
change start time in 15-minute
increments.
4.
Press
RIGHT ARROW
key to
add an additional
START TIME
to program displayed. The start
time number is shown in upper
left corner of display.
5.
Press
PRG
key to add
START
TIME
to a different program.
6.
Press
RETURN / ENTER
key to
proceed to next programming
function, or allow controller to
return to idle mode.
Setting Flush Duration Times
1.
Press
RETURN / ENTER
key until
HOURGLASS
icon is displayed.
RUN TIME
will be displayed
flashing. Also shown is program
letter (A, B, or C) and active
station # (always #1– all other
stations not used) on lower left
side of display.
2.
Press
+
or
–
key to change
station
RUN TIME
from 1 minute
to 6 hours.
3.
Press
PRG
key to add a
RUN TIME
to another program.
4.
Press
RETURN / ENTER
key to
proceed to next programming
function, or allow controller to
return to idle mode.t
Содержание Hydro-Guard HG-6